On May 12th, the biaseparations.com website will be retired and migrated tosartorius.com.Learn moreabout our combined offering today!
2005

N. Lendero, J. Vidič, P. Brne, A. Podgornik, A. Štrancar

Journal of Chromatography A, 1065 (2005) 29-38(2005) 29 - 38

The objective of this study was to develop a fast, simple, non-destructive, non-toxic and low-priced method for determining the amount of ionic groups on resins, since the conventional titration method fails to give proper results on methacrylate monoliths. After the column had been pre-saturated with a high concentration buffer solution, a low concentration buffer solution of the same pH value was pumped through the column. Measuring pH and absorbance, the profiles with a shape of typical break-through curve were obtained. It was shown that the time of the pH transient, which appeared under such conditions, could be used as a measure of the total ionic capacity of ion-exchange monolithic columns. The effect of the column length, linear velocity and varying concentrations of buffer solutions on the time of the pH transient was examined. The method was shown to be suitable for determining the amount of ionic groups on both anion and cation monolithic columns. In addition, it could also be applied to particle bed columns. The time of the pH transient and the protein dynamic binding capacity were also compared and it was concluded that for a given monolith the protein capacity can be derived from the data obtained by the new method.

Purchase full article

Full view

I. Mihelič, D. Nemec, A. Podgornik, T. Koloini

Journal of Chromatography A, 1065 (2005) 59-67(2005) 59 - 67

Pressure drop analysis in commercial CIM disk monolithic columns is presented. Experimental measurements of pressure drop are compared to hydrodynamic models usually employed for prediction of pressure drop in packed beds, e.g. free surface model and capillary model applying hydraulic radius concept. However, the comparison between pressure drop in monolith and adequate packed bed give unexpected results. Pressure drop in a CIM disk monolithic column is approximately 50% lower than in an adequate packed bed of spheres having the same hydraulic radius as CIM disk monolith; meaning they both have the same porosity and the same specific surface area. This phenomenon seems to be a consequence of the monolithic porous structure which is quite different in terms of the pore size distribution and parallel pore nonuniformity compared to the one in conventional packed beds. The number of self-similar levels for the CIM monoliths was estimated to be between 1.03 and 2.75.

Purchase full article

Full view

T. B. Tennikova, J. Reusch

Journal of Chromatography A, 1065 (2005) 13-17(2005) 13 - 17

The history of the development of short monolithic beds is described.

Purchase full article

Full view

J. Vidić, A. Podgornik, A. Štrancar

Journal of Chromatography A, 1065 (2005) 51-58(2005) 51-58

The influence of glass surface modification in order to determine strength of the monolith attachment was studied. Modification consists of pre-treatment of the glass with chemicals or boiling in deionized water, silanization and drying has been investigated on different types of glass. Amount of silane groups was determined by measurement of the contact angle between the glass surface and water drop. The highest values were found for soda–lime glass. Strength of the monolith attachment was established by pumping ethanol through the monolithic capillaries and measuring the pressure drop at which monolith was dislodged. Surprisingly, it was found that the critical part of the glass surface modification procedure is glass pre-treatment. Good results were obtained with glass boiled in water for 2.5 h or more.

Purchase full article

Full view

S. Yamamoto, A. Kita

Journal of Chromatography A, 1065 (2005) 45-50(2005) 45-50

Although linear salt gradient elution ion-exchange chromatography (IEC) of proteins is commonly carried out with relatively short columns, it is still not clear how the column length affects the separation performance and the economics of the process. The separation performance can be adjusted by changing a combination of the column length, the gradient slope and the flow velocity. The same resolution can be obtained with a given column length with different combinations of the gradient slope and the flow velocity. This results in different separation time and elution volume at the same resolution. Based on our previous model, a method for determining the separation time and the elution volume relationship for the same resolution (iso-resolution curve) was developed. The effect of the column length and the mass transfer rate on the iso-resolution curve was examined. A long column and/or high mass transfer rate results in lesser elution volume. The resolution data with porous bead packed columns and monolithic columns were in good agreement with the calculated iso-resolution curves. Although the elution volume can be reduced with increasing column length, the pressure drop limits govern the optimum conditions.

Purchase full article

Full view

Y.-P. Lim, D. Josić, H. Callanan, J. Brown, D. C. Hixson

Journal of Chromatography A, 1065 (2005) 39–43(2005) 39–43

Epoxy-activated monolithic CIM disks seem to be excellent supports for immobilization of protein ligands. The potential use of enzymes, immobilized on monolithic disks for rapid preparative cleavage proteins in solution was investigated. Digestion of complex plasma proteins was demonstrated by using inter-alpha inhibitors with elastase, immobilized on epoxy-activated CIM disks. Recently, a monoclonal antibody against human inter-alpha inhibitor proteins (MAb 69.31) was developed. MAb 69.31 blocks the inhibitory activity of inter-alpha inhibitor proteins to serine proteases. These results suggest that the epitope defined by this antibody is located within or proximal to the active site of the inhibitor molecule. This antibody, immobilized on monolithic disk, was used for very rapid isolation of inter-alpha proteins. The isolated complex protein was used for enzymatic digestion and isolation of cleavage products, especially from inter-alpha inhibitor light chain to elucidate precisely the target sequence for MAb 69.31 by N-terminal amino acid sequencing. Bovine pancreatic elastase immobilized on monolithic disk cleaves inter-alpha inhibitor protein complex into small fragments which are still reactive with MAb 69.31. One of these proteolytic fragments was isolated and partially sequenced. It could be shown that this sequence is located at the beginning of two proteinase inhibitor domains of the inter-alpha inhibitor light chain (bikunin). Elastase immobilized on monolithic disk offers a simple and rapid method for preparative isolation of protease cleavage fragments. The immobilized enzyme is stable and still active after repeated runs. A partial or complete digestion can be achieved by varying the flow rate.

Purchase full article

Call

Send SMS

Add to Skype

You'll need Skype CreditFree via Skype

Full view

M. Benčina, K. Benčina, A. Štrancar, A. Podgornik

Journal of Chromatography A, 1065 (2005) 83–91(2005) 83–91

A deoxyribonuclease bioreactor was prepared by immobilization of deoxyribonuclease I through epoxy groups inherently present on poly (glycidyl methacrylate-co-ethylene dimethacrylate) monoliths. Columns with various levels of DNase activity were prepared varying immobilization temperature, pH, time and method. The apparent Michaelis–Menten constant, Kmapp, and turnover number, k3app, for immobilized DNase determined by on-line frontal analysis method were, respectively, 0.28 g of DNA l-1 and 16 dA260nm min-1 mg-1 of immobilized DNase. The highest activity of immobilized DNase was detected at 1 mM calcium ions concentration and mirrored properties of free enzyme; however, reaction temperature in the range from 25 to 37 °C has no significant effect on activity of immobilized DNase in contrary to free enzyme. The CIM DNase bioreactor was used for elimination of DNA contaminants in RNA samples prior to reverse transcription followed by PCR.

Purchase full article

Call

Send SMS

Add to Skype

You'll need Skype CreditFree via Skype

Full view

D. Forčić, K. Branovič Čakanič, J. Ivančič, R. Jug, M. Barut, A. Štrancar, R. Mazuran

Analytical Biochemistry 336 (2005) 273-278

Analysis of crude samples from biotechnological processes is often required to demonstrate that residual host cell impurities are reduced or eliminated during purification. Current knowledge suggests that a continuous-cell-line DNA can be considered a cellular contaminant rather than a significant risk factor requiring removal to extremely low levels. Anion-exchange chromatography is one of the most important methods used in the downstream processing and analysis of different biomolecules. In this article, an application using Convective Interaction Media monolithic columns to improve the detection of residual cellular DNA is described.

Purchase full article

Full view

S. Jerman, A. Podgornik, K. Cankar, N. Čadež, M. Skrt, J. Žel, P. Raspor

Journal of Chromatography A 1065 (2005) 107-113

The availability of sufficient quantities of DNA of adequate quality is crucial in polymerase chain reaction (PCR)-based methods for genetically modified food detection. In this work, the suitability of anion-exchange CIM (Convective Interaction Media; Sartorius BIA Separations, Ljubljana, Slovenia) monolithic columns for isolation of DNA from food was studied. Maize and its derivates corn meal and thermally pre-treated corn meal were chosen as model food. Two commercially available CIM disk columns were tested: DEAE (diethylaminoethyl) and QA (quaternary amine). Preliminary separations were performed with standard solution of salmon DNA at different pH values and different NaCl concentrations in mobile phase. DEAE groups and pH 8 were chosen for further isolations of DNA from a complex matrix—food extract. The quality and quantity of isolated DNA were tested on agarose gel electrophoresis, with UV-scanning spectrophotometry, and by amplification with real-time PCR. DNA isolated in this way was of suitable quality for further PCR analyses. The described method is also applicable for DNA isolation from processed foods with decreased DNA content. Furthermore, it is more effective and less time-consuming in comparison with the existing proposed methods for isolation of DNA from plant-derived foods.

Purchase full article

Full view

D. Forčić, K. Branović-Čakanić, J. Ivančić, R. Jug, M. Barut, A. Štrancar

Journal of Chromatography A 1065 (2005) 115-120

The isolation and purification of nucleic acids is essential for many procedures in molecular biology. After showing that bacterial and eukaryotic genomic DNA can be specifically bound to the CIM DEAE monolithic column, this characteristic was exploited in development of a simple and fast chromatographic procedure for isolation and purification of genomic DNA from cell lysates that does not include the usage of toxic organic solutions. The purity and the quality of the isolate as well as the duration of the procedure was similar to other chromatographic methods used today for isolation of genomic DNA, but the initial sample volume was not restricted.

Purchase full article

Full view

J. Urthaler, R. Schlegl, A. Podgornik, A. Štrancar, A. Jungbauer, R. Necina

Journal of Chromatography A 1065 (2005) 93-106

The demand of high-purity plasmid DNA (pDNA) for gene-therapy and genetic vaccination is still increasing. For the large scale production of pharmaceutical grade plasmids generic and economic purification processes are needed. Most of the current processes for pDNA production use at least one chromatography step, which always constitutes as the key-step in the purification sequence. Monolithic chromatographic supports are an alternative to conventional supports due to their excellent mass transfer properties and their high binding capacity for pDNA. Anion-exchange chromatography is the most popular chromatography method for plasmid separation, since polynucleotides are negatively charged independent of the buffer conditions. For the implementation of a monolith-based anion exchange step into a pDNA purification process detailed screening experiments were performed. These studies included supports, ligand-types and ligand-densities and optimization of resolution and productivity. For this purpose model plasmids with a size of 4.3 and 6.9 kilo base pairs (kbp) were used. It could be shown, that up-scaling to the production scale using 800 ml CIM Convective Interaction Media radial flow monoliths is possible under low pressure conditions. CIM DEAE was successfully implemented as intermediate step of the cGMP pDNA manufacturing process. Starting from 200 l fermentation aliquots pilot scale purification runs were performed in order to prove scale-up and to predict further up-scaling to 8 l tube monolithic columns. The analytical results obtained from these runs confirmed suitability for pharmaceutical applications.

Purchase full article

Full view

M. Peterka, P. Kramberger, A. Štrancar

WANG, Perry G. (ur.). Monolithic chromatography and its modern applications. St Albans: ILM publications, 2010, pg. 489-508

Downstream processing (DSP) for purification can become a significant bottleneck in the production of novel biotherapeutics, such as viral vectors and vaccines (viral or DNA). Although different techniques can be used for the purification of large molecules and particles, liquid chromatography is the preferred method as it achieves the purity required by regulatory agencies. Despite the popularity of conventional chromatographic media, the diffusional mass transfer of large molecules and relatively small pore size remain limiting factors for the efficient separation of large biomolecules and particles. Methacrylate monoliths are a single-piece chromatographic support that consists of a highly porous material with an interconnected network of channels. The transport mechanism is predominantly based on convection, which allows rapid mass transfer between the mobile and stationary phase and so results in short separation times. Additionally, most of the active sites are located in the open, large channel structure and are therefore easily accessible, which results in a high DBC (DBC) for large molecules and viral particles. These characteristics make methacrylate monoliths an ideal chromatographic support for the separation and purification of extremely large molecules, such as large proteins, different types of DNA and virus particles.

Full view

2004

A. Podgornik, J. Jančar, M. Merhar, S. Kozamernik, D. Glover, K. Čuček, M. Barut, A. Štrancar

J. Biochem. Biophys. Methods 60 (2004) 179–189

Monoliths represent a special class of chromatographic supports. In contrast to other stationary phases, they consist of a single piece of highly porous material through which a sample is mainly transported by convection. As a consequence, monoliths enable fast separations and exhibit flow-unaffected properties, which make them attractive for purification of macromolecules like proteins or DNA. In this work, methacrylate-based monolithic columns with the bed volume up to 8000 ml are characterized. They perform high-resolution separations of several hundreds of grams of proteins per hour by utilizing liter per minute flow rates. They are incompressible under these operating conditions and resistant to strong alkaline conditions.

Purchase full article

Full view

T. Hall, D. C. Wood, C. E. Smith

Journal of Chromatography A, 1041 (2004) 87–93(2004) 87–93

Monolithic media were compared with Q- and SP-Sepharose high performance chromatography for preparative purification and with Q- and SP-5PW chromatography for analysis of a pegylated form of myelopoietin (MPO), an engineered hematopoietic growth factor. The use of either monolithic or Sepharose based supports for preparative chromatography produced highly purified pegylated MPO with the monolithic media demonstrating peak resolution and repeatability at flow rates of 1 and 5 ml/min resulting in run times as much as five-fold shorter compared to Sepharose separations. The monolithic disks also resulted in 10-fold shorter run times for the analytical chromatography, however, their chromatographic profiles and peak symmetry were not as sharp compared to their Q-5PW and SP-5PW counterparts.

Purchase full article

Full view

E. Vlakh, A. Novikov, G. Vlasov, T. Tennikova

Journal of Peptide Science, 10: 719–730 (2004)

Monoliths based on a copolymer of glycidyl methacrylate (GMA) and ethylene dimethacrylate (EDMA) can be used directly as sorbents for affinity chromatography after solid phase peptide synthesis. The quality of the synthesized products, the amount of grown peptides on a support and the reproducibility of the process must be considered. A determination of the quantity of the introducing β-Ala (and, consequently, the total amount of synthesized peptide) was carried out. Three peptides complementary to recombinant tissue plasminogen activator (t-PA) have been synthesized using Fmoc-chemistry on GMA-EDMA disks. The peptidyl ligands were analysed by amino acid analysis, ES-MS and HPLC methods.

The affinity binding parameters were obtained from frontal elution data. The results were compared with those established for GMA-EDMA affinity sorbents formed by the immobilization of the same but separately synthesized and purified ligands. The immobilization on GMA-EDMA disks was realized using a one-step reaction between the amino groups of the synthetic ligand and the original epoxy groups of monolithic material. The affinity constants found for two kinds of sorbent did not vary significantly. Finally, the directly obtained affinity sorbents were tested for t-PA separation from a cellular supernatant.

Purchase full article

Full view

D. Ren, N. A. Penner, B. E. Slentz, H. D. Inerowicz, M. Rybalko, F. E. Regnier

Journal of Chromatography A, 1031 (2004) 87–92(2004) 87–92

Immobilized copper(II) affinity chromatography [Cu(II)-immobilized metal affinity chromatography (IMAC)] has been used in proteomics to simplify sample mixtures by selecting histidine-containing peptides from proteolytic digests. This paper examines the specificity of four different support materials with an iminodiacetic acid (IDA) stationary phase in the selection of only histidine-containing peptides in the single step capture-release mode. Three of the sorbents examined were commercially available: HiTrap Chelating HP (agarose), TSK Chelate-5PW, and Poros 20MC. IDA was also immobilized on CIM discs (monolithic glycidylmethacrylate-ethylene dimethacrylate). Tryptic digests of transferrin and β-galactosidase were used as model samples to evaluate these sorbents. It was found that among the examined matrices, the TSK Chelate-5PW sorbent bound histidine-containing peptides the strongest, while Poros matrix was found to have a high degree of non-specific bindings. Agarose-based columns showed relatively high selectivity and specificity.

Purchase full article

Full view

E. G. Vlakh, A. Tappe, C. Kasper, T. B. Tennikova

Journal of Chromatography B, 810 (2004) 15–23

Plasminogen activators are the proteases which convert plasminogen into plasmin dissolving, in its turn, the major component of blood clots, fibrin. They are extremely useful in heart attack therapy. Modern and most appropriate way of scaled up production of these valuable proteins is gene engineering. In this case, a separation and a purification of target product become the important steps of the whole process. Recently developed affinity chromatography on short monolithic columns seems to be a very attractive method for these purposes. High speed of a process prevents the protein’s denaturation due to temperature or/and solvents influence. The better mass transfer mechanism (convection rather than diffusion) allows considering only biospecific complexing as time limiting step. Specificity of several synthetic peptides to plasminogen activators have been studied by affinity chromatography on short monolithic columns. Peptide ligands were synthesized by conventional solid phase peptide synthesis (SPPS). The immobilization procedure was carried out as a one step process at static conditions. The results of quantitative evaluation of such affinity interactions were compared with those established for plasminogen that is the natural affinity counterpart to both proteases. Additionally, some of investigated peptides were synthesized directly on GMA–EDMA disks and their affinity properties were compared with those established for the case of immobilized ligands. The possibility of using of synthetic peptidyl ligands for plasminogen activators isolation from native cell supernatant and model protein mixtures has been demonstrated.

Purchase full article

Full view

D. G. Glover, M. Barut, A. Podgornik, M. Peterka, A. Štrancar

BioProcess International, Oct 2004, 58-63

The sequencing of the human genome and the rise of proteomics have increased the numbers of potential therapeutic targets. Biotechnology companies need to increase productivity, decrease discovery and production costs, and use technologies that easily transfer across departments if they wish to remain competitive. The most important tools are those for separation (purification) of target substance(s). They should be easy to use and offer an identical performance and purification profile no matter where they are implemented — in discovery, production, or quality assurance (QA).

CIM Convective Interaction Media short monolithic columns are just such a unifying technology. Produced in shapes and sizes from microliter to liter scale, they represent an evolutionary approach to meeting biochromatographic separation requirements in research and product development. Able to withstand 1 M NaOH with no loss of capacity or resolution, these easily scalable columns have been optimized for analysis and cGMP production of complex biomolecules ranging from oligonucleotides and plasmid DNA (pDNA) to proteins and viruses.

Read full article

Full view

E. G. Vlakh, A. Tappe, C. Kasper, T. B. Tennikova

Journal of Chromatography B, 810 (2004) 15–23

Plasminogen activators are the proteases which convert plasminogen into plasmin dissolving, in its turn, the major component of blood clots, fibrin. They are extremely useful in heart attack therapy. Modern and most appropriate way of scaled up production of these valuable proteins is gene engineering. In this case, a separation and a purification of target product become the important steps of the whole process. Recently developed affinity chromatography on short monolithic columns seems to be a very attractive method for these purposes. High speed of a process prevents the protein’s denaturation due to temperature or/and solvents influence. The better mass transfer mechanism (convection rather than diffusion) allows considering only biospecific complexing as time limiting step. Specificity of several synthetic peptides to plasminogen activators have been studied by affinity chromatography on short monolithic columns. Peptide ligands were synthesized by conventional solid phase peptide synthesis (SPPS). The immobilization procedure was carried out as a one step process at static conditions. The results of quantitative evaluation of such affinity interactions were compared with those established for plasminogen that is the natural affinity counterpart to both proteases. Additionally, some of investigated peptides were synthesized directly on GMA–EDMA disks and their affinity properties were compared with those established for the case of immobilized ligands. The possibility of using of synthetic peptidyl ligands for plasminogen activators isolation from native cell supernatant and model protein mixtures has been demonstrated.

Purchase full article

Full view

E. G. Vlakh, A. Tappe, C. Kasper, T. B. Tennikova

Journal of Chromatography B, 810 (2004) 15–23

Plasminogen activators are the proteases which convert plasminogen into plasmin dissolving, in its turn, the major component of blood clots, fibrin. They are extremely useful in heart attack therapy. Modern and most appropriate way of scaled up production of these valuable proteins is gene engineering. In this case, a separation and a purification of target product become the important steps of the whole process. Recently developed affinity chromatography on short monolithic columns seems to be a very attractive method for these purposes. High speed of a process prevents the protein’s denaturation due to temperature or/and solvents influence. The better mass transfer mechanism (convection rather than diffusion) allows considering only biospecific complexing as time limiting step. Specificity of several synthetic peptides to plasminogen activators have been studied by affinity chromatography on short monolithic columns. Peptide ligands were synthesized by conventional solid phase peptide synthesis (SPPS). The immobilization procedure was carried out as a one step process at static conditions. The results of quantitative evaluation of such affinity interactions were compared with those established for plasminogen that is the natural affinity counterpart to both proteases. Additionally, some of investigated peptides were synthesized directly on GMA–EDMA disks and their affinity properties were compared with those established for the case of immobilized ligands. The possibility of using of synthetic peptidyl ligands for plasminogen activators isolation from native cell supernatant and model protein mixtures has been demonstrated.

Purchase full article

Full view