On May 12th, the biaseparations.com website will be retired and migrated tosartorius.com.Learn moreabout our combined offering today!
2013

H. G. Schwelberger, J. Feurle, F. Ahrens

Journal of Neural Transmission 120 (2013) 983-986

Diamine oxidase (DAO) was purified to homogeneity from human seminal plasma by consecutive chromatographic fractionation on heparin-sepharose, phenyl-sepharose, CIM-QA, and Superdex 200. Human seminal plasma DAO behaves electrophoretically similar to DAO proteins from other human tissues and has very similar enzymatic properties with histamine and aliphatic diamines being the preferred substrates as well as significant conversion of polyamines. The cellular source and functional importance of DAO in human semen remain to be determined.

Purchase full article

Full view

E. A. Ponomareva, M. V. Volokitina, D. O. Vinokhodov, E. G. Vlakh, T. B. Tennikova

Anal Bioanal Chem (2013) 405:2195–2206

Immobilized enzyme reactors (IMERs) produced by the covalent attachment of ribonuclease A to macroporous
methacrylate-based monolithic supports using different experimental approaches are discussed and compared. Enzyme immobilization was carried out by direct covalent binding, as well as through attachment via a polymer spacer. The kinetic properties of an IMER operating in either recirculation mode or zonal elution mode were studied. Additionally, the effect of flow rate on the bioconversion efficiency of each IMER sample was examined.

Purchase full article

Full view

M. V. Volokitina, E. G. Vlakh, G. A. Platonova, D. O. Vinokhodov, T. B. Tennikova
J. Sep. Sci. 2013, 36, 2793-2805

Two ribonuclease A bioreactors based on lab-made macroporous monolithic columns and intended for polynucleotide degradation were prepared using in situ free-radical polymerization. Different methods of enzyme immobilization were applied. In the first case, the biocatalyst molecule was attached to the solid surface via direct covalent binding, while in the second bioreactor the flexible-chain synthetic polymer was used as an intermediate spacer. The effect of temperature, substrate flow rate, and loaded sample volume on the biocatalytic efficiency of the immobilized enzyme was examined. The kinetic parameters of the enzymatic degradation of synthetic polycytidylic acid were calculated and compared to those found for hydrolysis with soluble ribonuclease A. The monitoring of substrate splitting was carried out by means of fast anion-exchange HPLC on an ultra-short monolithic column (disk) using off- and on-line analytical approaches.

Purchase full article

Full view

E. Maksimova, E. Vlakh, E. Sinitsyna, T. Tennikova
J. Sep. Sci. 2013, 36, 3741–3749

Ultrashort monolithic columns (disks) were thoroughly studied as efficient stationary phases for precipitation–dissolution chromatography of synthetic polymers. Gradient elution mode was applied in all chromatographic runs. The mixtures of different flexible chain homopolymers, such as polystyrenes, poly(methyl methacrylates), and poly(tert-butylmethacrylates) were separated according to their molecular weights on both commercial poly(styrene-co divinylbenzene).
disks (12 id × 3 mm and 5 × 5 mm) and lab-made monolithic columns (4.6 id × 50 mm) filled with supports of different hydrophobicity. The experimental conditions were optimized to reach fast and highly efficient separation. It was observed that, similar to the separation of monoliths of other classes of (macro)molecules (proteins, DNA, oligonucleotides), the length of column did not affect the peak resolution.
A comparison of the retention properties of the poly(styrene-co-divinylbenzene) diskshaped monoliths with those based on poly(lauryl methacrylate-co-ethylene dimethacrylate), poly(butyl methacrylate-co-ethylene dimethacrylate), and poly(glycidyl methacrylate-co-ethylene dimethacrylate) supports demonstrated the obvious effect of surface chemistry on the resolution factor. Additionally, the results of the discussed chromatographic mode on the fast determination of the molecular weights of homopolymers used in this study were compared to those established by SEC on columns packed with sorbent beads of a similar nature to the monoliths.

Purchase full article

Full view

Roy N D‘Souza, Ana M Azevedo, M Raquel Aires-Barros, Nika Lendero Krajnc, Petra Kramberger, Maria Laura Carbajal, Mariano Grasselli, Roland Meyer & Marcelo Fernández-Lahore

Vol. 1, No. 5, Pharmaceutical Bioprocessing (2013)

Downstream processing is currently the major bottleneck for bioproduct generation. In contrast to the advances in fermentation processes, the tools used for downstream processes have struggled to keep pace in the last 20 years. Purification bottlenecks are quite serious, as these processes can account for up to 80% of the total production cost. Coupled with the emergence of new classes of bioproducts, for example, virus-like particles or plasmidic DNA, this has created a great need for superior alternatives. In this review, improved downstream technologies, including aqueous two-phase systems, expanded bed adsorption chromatography, convective flow systems, and fibre-based adsorbent systems, have been discussed. These adaptive methods are more suited to the burgeoning downstream processing needs of the future, enabling the cost-efficient production of new classes biomaterials with a high degree of purity, and thereby hold the promise to become indispensable tools in the pharmaceutical and food industries.

Purchase full article

Full view

2012

J. Lee, H. T. Gan, S. M. Abdul Latiff , C. Chuah, W. Y. Lee, Y.-S. Yang, B. Loo, S. K. Ng, P. Gagnon

Journal of Chromatography A, 1270 (2012) 162-170

We introduce a chromatography method for purification of large proteins and viruses that works by capturing them at a non-reactive hydrophilic surface by their mutual steric exclusion of polyethylene glycol (PEG). No direct chemical interaction between the surface and the target species is required. We refer to the technique as steric exclusion chromatography. Hydroxyl-substituted polymethacrylate monoliths provide a hydrophilic surface and support convective mass transport that is unaffected by the viscosity of the PEG. Elution is achieved by reducing PEG concentration. Selectivity correlates with molecular size, with larger species retained more strongly than smaller species. Retention increases with PEG size and concentration. Salts weaken retention in proportion to their concentration and Hofmeister ranking. Retention is enhanced near the isoelectric point of the target species. Virus binding capacity was measured at 9.9 × 1012 plaque forming units per mL of monolith. 99.8% of host cell proteins and 93% of DNA were eliminated. Mass recovery exceeded 90%. IgM capacity was greater than 60 mg/mL. 95% of host cell proteins were eliminated from IgM produced in protein-free media, and mass recovery was up to 90%. Bioactivity was fully conserved by both viruses and antibodies. Process time ranged from less than 30 min to 2 h depending on the product concentration in the feed stream.

Purchase full article

Full view

P. Gagnon

Journal of Chromatography A, 1221 (2012) 57-70(2012) 57-70

This article reviews technology trends in antibody purification. Section 1 discusses non-chromatography methods, including precipitation, liquid–liquid extraction, and high performance tangential flow filtration. The second addresses chromatography methods. It begins with discussion of fluidized and fixed bed formats. It continues with stationary phase architecture: diffusive particles, perfusive particles, membranes and monoliths. The remainder of the section reviews recent innovations in size exclusion, anion exchange, cation exchange, hydrophobic interaction, immobilized metal affinity, mixed-mode, and bioaffinity chromatography. Section 3 addresses an emerging trend of formulating process buffers to prevent or correct anomalies in the antibodies being purified. Methods are discussed for preventing aggregate formation, dissociating antibody-contaminant complexes, restoring native antibody from aggregates, and conserving or restoring native disulfide pairing.

Purchase full article

Full view

J. Subotič, K. Koruza, B. Gabor, M. Peterka, M. Barut, J. Kos, J. Brzin

Affinity Chromatography, Dr. Sameh Magdeldin (Ed.), ISBN: 978-953-51-0325-7, InTech

Proteolytic enzymes (also known as proteases, proteinases or peptidases) offer a wide range of applications. They are routinely used in detergent, leather, food and pharmaceutical industries, as well as in medical and basic research. Therefore, effective isolation procedures are of great importance. The chapter describes the use of recently discovered protease inhibitors from basidiomycetes as affinity chromatography ligands for isolating proteases. Affinity columns with serine and cysteine protease inhibitors immobilized to the natural polymer Sepharose have been prepared, the chromatography procedure optimized and used for isolating proteases from various bacterial, plant and animal sources. The cysteine protease inhibitor macrocypin showed superior characteristics as a ligand, so was selected for immobilization to CIM (Convective Interaction Media) monolithic disks. Different immobilization chemistries and process conditions were optimized to determine the best conditions for high capacity and selectivity. A very effective method for isolating cysteine proteases was developed using affinity chromatography with the fungal cysteine protease inhibitor macrocypin immobilized to a CIM monolithic disk.

Read full article

Full view

M. Žorž

ChemieXtra 3/2012 pp 30-33

Sartorius BIA Separations produziert und vertreibt kurze monolithischen Chromatografiesäulen, die auf der CIM-Convective Interaction Media-Technologie basieren. CIM-Säulen eignen sich vor allem für die Reinigung von grossen Biomolekülen wie etwa Viren (virale Vektoren und Impfstoffe), DNA (Plasmid-DNA) und grössere Proteine (Immunglobuline G und M, pegylierte Proteine). Sie weisen einzigartige Eigenschaften in Bezug auf operative Flussraten, Adsorptionsfähigkeit und Trennung grosser Biomoleküle auf. Die Säulen werden in Forschung, Labor, Pilot- und industriellen Produktionsstufen eingesetzt und sind extrem einfach zu handhaben.

Read full article

Full view

R. Milačič, D. Ajlec, T. Zuliani, D. Žigon, J. Ščančar

Talanta 101 (2012) 203-210

In human milk zinc (Zn) is bound to proteins and low molecular mass (LMM) ligands. Numerous investigations demonstrated that Zn bioavailability in human milk is for infant much higher than in cow's milk. It was presumed that in the LMM human milk fraction highly bioavailable Zn-citrate prevails. However, literature data are controversial regarding the amount of Zn-citrate in human milk since analytical procedures reported were not quantitative. So, complex investigation was carried out to develop analytical method for quantitative determination of this biologically important molecule. Studies were performed within the pH range 5–7 by the use of synthetic solutions of Zn-citrate prepared in HEPES, MOPS and MES buffers. Zn-citrate was separated on weak anion-exchange convective interaction media (CIM) diethylaminoethyl (DEAE) monolithic chromatographic column using NH4NO3 as an eluent. Separated Zn species were determined by flame atomic absorption spectrometry (FAAS) or inductively coupled plasma mass spectrometry (ICP-MS). Quantitative separation of Zn-citrate complexes ([Zn(Cit)]- and [Zn(Cit)2]4-; column recoveries 94–102%) and good repeatability and reproducibility of results with relative standard deviation (RSD±3.0%) were obtained. In fractions under the chromatographic peaks Zn-binding ligand was identified by electrospray ionization tandem mass spectrometry (ESI-MS-MS). Limits of detection (LOD) for determination of Zn-citrate species by CIM DEAE-FAAS and CIM DEAE-ICP-MS were 0.01 μg Zn mL-1 and 0.0005 μg Zn mL-1, respectively. Both techniques were sensitive enough for quantification of Zn-citrate in human milk. Results demonstrated that about 23% of total Zn was present in the LMM milk fraction and that LMM-Zn corresponded to Zn-citrate. The developed speciation method represents a reliable analytical tool for investigation of the percentage and the amount of Zn-citrate in human milk.

Purchase full article

Full view

2011

S. H. Lubbad, M. R. Buchmeiser

Journal of Chromatography A, 1218 (2011) 2362-2367

Ring-opening metathesis polymerization- (ROMP) derived monoliths were prepared from 5-norborn-2-enemethyl bromide (NBE-CH2Br) and tris(5-norborn-2-enemethoxy)methylsilane ((NBE-CH2O)3SiCH3) within the confines of surface-silanized borosilicate columns (100 × 3 mm I.D.), applying Grubbs’ first generation benzylidene-type catalyst [RuCl2(PCy3)2(CHPh)]. Monoliths were converted into weak anion exchangers via reaction with diethyl amine. The resulting monolithic anion exchangers demonstrated a very good potential for the anion-exchange separation of nucleic acids applying a phosphate buffer (0.05 mol/L, pH 7) and NaCl (1.0 mol/L) as a gradient former. Fast and efficient separations, indicated by sharp and highly symmetric analyte peaks, were established. Except for the 267 and 298 base pair fragments, the eleven fragments of a ds-pUC18 DNA Hae III digest were baseline separated within ∼8 min. Nineteen fragments of a ds-pBR322 Hae III digest were separated within ∼12 min. There, only the 192 and 213 base pair fragments and the 458, 504 and 540 base pair fragments coeluted. A ds-pUC18 DNA Hae III digest was used as a control analyte in evaluating the influence of organic additives on the mobile phase such as methanol and acetonitrile on nucleic acid separation. Methanol, and even better, acetonitrile improved the separation efficiency and shortened the analysis time.

Purchase full article

Full view

S. Yamamoto, T. Okada, M. Abe, N. Yoshimoto

Journal of Chromatography A, 1218 (2011) 2460-2466

The peak spreading of DNAs of various sizes [12-mer, 20-mer, 50-mer and 95-mer poly(T)] in linear gradient elution (LGE) chromatography with a thin monolithic disk was investigated by using our method developed for determining HETP in LGE. Electrostatic interaction-based chromatography mode (ion-exchange chromatography, IEC) was used. Polymer-based monolithic disks of two different sizes (12 mm diameter, 3 mm thickness and 0.34 mL; 5.2 mm diameter, 4.95 mm thickness and 0.105 mL) having anion-exchange groups were employed. For comparison, a 15-μm porous bead IEC column (Resource Q, 6.4 mm diameter, 30 mm height and 0.97 mL) was also used. The peak width did not change with the flow velocity for the monolithic disks where as it became wider with increasing velocity. For the monolithic disks the peak width normalized with the column bed volume was well-correlated with the distribution coefficient at the peak position KR. HETP values were constant (ca. 0.003–0.005 cm) when KR > 5. Much higher HETP values which are flow-rate dependent were obtained for the porous bead chromatography. It is possible to obtain 50–100 plates for the 3 mm monolithic disk. This results in very sharp elution peaks (standard deviation/bed volume = 0.15) even for stepwise elution chromatography, where the peak width is similar to that for LGE of a very steep gradient slope.

Purchase full article

Full view

Z. Jiang, N. W. Smith, Z. Liu

Journal of Chromatography A, 1218 (2011) 2350-2361

Hydrophilic interaction chromatography (HILIC) has experienced increasing attention in recent years. Much research has been carried out in the area of HILIC separation mechanisms, column techniques and applications. Because of their good permeability, low resistance to mass transfer and easy preparation within capillaries, hydrophilic monolithic columns represent a trend among novel HILIC column techniques. This review attempts to present an overview of the preparation and applications of HILIC monolithic columns carried out in the past decade. The separation mechanism of various hydrophilic monolithic stationary phases is also reviewed.

Purchase full article

Full view

R. D. Arrua, C. I. Alvarez Igarzabal

J. Sep. Sci. 2011, 34, 1974–1987

In the early 1990s, three research groups simultaneously developed continuous macroporous rod-shaped polymeric systems to eliminate the problem of flow through the interparticle spaces generally presented by the chromatography columns that use particles as filler. The great advantage of those materials, forming a continuous phase rod, is to increase the mass transfer by convective transport, as the mobile phase is forced to go through all means of separation, in contrast to particulate media where the mobile phase flows through the interparticle spaces. Due to their special characteristics, the monolithic polymers are used as base-supports in different separation techniques, those chromatographic processes being the most important and, to a greater extent, those involving the separation of biomolecules as in the case of affinity chromatography. This mini-review reports the contributions of several groups to the development of macroporous monoliths and their modification by immobilization of specific ligands on the products for their application in affinity chromatography.

Purchase full article

Full view

H. Shirataki, C. Sudoh, T. Eshima, Y. Yokoyama, K. Okuyama

Journal of Chromatography A, 1218 (2011) 2381–2388

It is widely recognized that membrane adsorbers are powerful tools for the purification of biopharmaceutical protein products and for this reason a novel hollow-fiber AEX type membrane adsorber has been developed. The membrane is characterized by grafted chains including DEA ligands affixed to the pore surfaces of the membrane. In order to estimate the membrane performance, (1) dynamic binding capacities for pure BSA and DNA over a range of solution conductivity and pH, (2) virus reduction by flow-through process, and (3) HCP and DNA removal from cell culture, are evaluated and compared with several other anion-exchange membranes. The novel hollow-fiber membrane is tolerant of high salt concentration when adsorbing BSA and DNA. When challenged with a solution containing IgG the membrane has high impurity removal further indicating this hollow-fiber based membrane adsorber is an effective tool for purification of biopharmaceutical protein products including IgG.

Purchase full article

Full view

2010

P. Gagnon

BioProcess International, Nov 2010

The enabling value of monoliths was strongly in evidence at the 4th International Monolith Symposium, held 29 May – 2 June in the Adriatic resort city of Portoroz, Slovenia. Forty-seven oral presentations and 34 posters highlighted important advances in vaccines, gene therapy, phage therapy for infectious disease, and monoclonal antibodies, as well as continuing advances in the performance of monoliths themselves. As these fields advance in parallel, it becomes increasingly apparent that monoliths offer industrial capabilities substantially beyond traditional methods.

Read full article

Full view

F. Mancini, V. Andrisano

Journal of Pharmaceutical and Biomedical Analysis 52 (2010) 355-361

A novel liquid chromatographic method has been developed for use in throughput screening of new inhibitors of human recombinant β-amyloid precursor protein cleaving enzyme (hrBACE1). The approach is based on the use of an immobilized enzyme reactor (IMER) containing the target enzyme (hrBACE1–IMER) and uses fluorescence detection. The bioreactor was prepared by immobilizing hrBACE1 on an ethylendiamine (EDA) monolithic disk (CIM) and a fluorogenic peptide (M-2420) containing the β-secretase site of the Swedish mutation of amyloid precursor protein (APP) was used as substrate. After injection into the hrBACE1–IMER system, M-2420 was enzymatically cleaved, giving rise to a fluorescent methoxycoumaryl-fragment (Rt = 1.6 min), which was separated from the substrate and selectively detected at λexc = 320 and λem = 420 nm. Product and substrate were characterized by using a post monolithic C18 stationary phase coupled to an ion trap mass analyser. A calibration curve was constructed to determine the immobilized hrBACE1–IMER rate of catalysis and kinetic constants. Specificity of the enzymatic cleavage was confirmed by injecting the substrate on a blank CIM-EDA.

The proposed method was validated by the determination of the inhibitory potency of five reference compounds with activities ranked over four order of magnitude (four peptidic inhibitors and a green tea polyphenol, (−)gallocatechin gallate). The obtained results were found in agreement with the data reported in literature, confirming the validity and the applicability of the hrBACE1–IMER as a tool for the fast screening of unknown inhibitors (more than 6 compounds per hour). Moreover, the hrBACE1–IMER showed high stability during the analysis, permitting its use for more than three months without affecting enzyme activity.

Purchase full article

Full view

E.A. Ponomareva, V.E. Kartuzova, E.G. Vlakh, T.B. Tennikova

Journal of Chromatography B, 878 (2010) 567–574

The effect of different modes of α-chymotrypsin attachment to the surface of methacrylate-based ultrashort monolithic minicolumns on enzyme activity has been studied. The immobilization of protease was carried out via direct covalent binding of chymotrypsin, as well as via its attachment through small and polymer spacers. It was established that the lowest enzyme activity against N-benzoyl-l-tyrosine ethyl ester was found for bioreactor obtained via direct attachment of chymotrypsin to the surface of GMA–EDMA minidisks, whereas the highest parameter close to that determined for dissolved enzyme was found in the case of bioreactor prepared by the introduction of copolymer of 2-deoxy-N-methacryloylamido-d-glucose with N-vinylpyrrolidone and acrolein as a long and flexible polymer spacer. Additionally, the effect of flow rate of substrate recirculation on bioconversion efficiency was examined. Independently on immobilization method, the increase of flow rate led to the raise of biocatalytic efficiency.

Purchase full article

Full view

P. Gagnon

Roadmap to Process Development, issue 3/2010, Sartorius BIA Separations

Introduction

The first two articles in this series addressed column selectivity and capacity. This article discusses how to apply results from these preliminary studies to create fully functional multi-step purification procedures. The principles described here can be applied to proteins, plasmids, or virus particles.

Process modeling represents a nexus at which the theoretical ideals of purification meet the practical limitations of the laboratory, or in less elegant terms: where the rubber meets the road. The key theoretical principle is the notion of developing an orthogonal purification process. Orthogonal means pertaining to right angles. In purification terms, it translates to combining purification methods that are highly complementary to one another. Its value resides in the presumption that different purification methods bind the product by different sites, along with a unique subset of contaminants. The more complementary the methods, the lower the overlap in contaminant subsets, and the higher the purification factor offered by the particular combination of methods.

Attachments

Full view

2009

P. Gagnon

Roadmap to Process Development, issue 2/2009, Sartorius BIA Separations

Introduction

Determination of column loading capacity is a critical component of purification process development. Its most obvious link is to process economics, since the more product that can be loaded per unit of media volume, the smaller the column and volume of buffers, and the smaller the process footprint (manufacturing space requirement). But binding capacity is also linked directly to loading conditions, and beyond that, loading is a key determinant of purification performance and reproducibility. In practice, determination of optimal loading is tedious, time consuming, and expensive, especially due to the large amounts of sample it requires. This makes it all the more important to get it right the first time.

The objectives of this article are to highlight the process considerations that pertain to loading, and to provide you with a set of practical tools to determine capacity values that are meaningful in your particular usage context.

Attachments

Full view