E.A. Ponomareva, V.E. Kartuzova, E.G. Vlakh, T.B. Tennikova

Journal of Chromatography B, 878 (2010) 567–574

The effect of different modes of α-chymotrypsin attachment to the surface of methacrylate-based ultrashort monolithic minicolumns on enzyme activity has been studied. The immobilization of protease was carried out via direct covalent binding of chymotrypsin, as well as via its attachment through small and polymer spacers. It was established that the lowest enzyme activity against N-benzoyl-l-tyrosine ethyl ester was found for bioreactor obtained via direct attachment of chymotrypsin to the surface of GMA–EDMA minidisks, whereas the highest parameter close to that determined for dissolved enzyme was found in the case of bioreactor prepared by the introduction of copolymer of 2-deoxy-N-methacryloylamido-d-glucose with N-vinylpyrrolidone and acrolein as a long and flexible polymer spacer. Additionally, the effect of flow rate of substrate recirculation on bioconversion efficiency was examined. Independently on immobilization method, the increase of flow rate led to the raise of biocatalytic efficiency.

Purchase full article

Full view

A. Čevdek, M. Franko

Analytical and Bioanalytical Chemistry 398 (2010), 555-562

This work presents a comparison of convective interaction media (CIM) and controlled pore glass (CPG) as solid supports for immunoglobulin antibodies used in bioanalytical detection of allergens in foodstuffs. A flow-injection manifold with highly sensitive thermal lens spectrometric detection was used for this purpose. Using beta-lactoglobulin, a milk allergen, as a model analyte, CIM disc supports had a higher linear range (0.2–3.5 μg L-1), better reproducibility (intra-day RSD = 1%, inter-day RSD = 10%), lower consumption of reagents, and better immunocolumn stability (1 month, over 240 injections of substrate), while providing comparable LODs (0.1 μg L-1). Application of CIM discs as solid supports in immunocolumns for allergen detection enables fast and sensitive screening of allergens in foodstuffs with sample throughput of up to eight samples per hour.

Purchase full article

Full view

2009

P. Brne, Y.-P. Lim, A. Podgornik, M. Barut, B. Pihlar, A. Štrancar

Journal of Chromatography A, 1216 (2009) 2658-2663

Convective interaction media (CIM; Sartorius BIA Separations) monoliths are attractive stationary phases for use in affinity chromatography because they enable fast affinity binding, which is a consequence of convectively enhanced mass transport. This work focuses on the development of novel CIM hydrazide (HZ) monoliths for the oriented immobilization of antibodies. Adipic acid dihydrazide (AADH) was covalently bound to CIM epoxy monoliths to gain hydrazide groups on the monolith surface. Two different antibodies were afterwards immobilized to hydrazide functionalized monolithic columns and prepared columns were tested for their selectivity. One column was further tested for the dynamic binding capacity.

Purchase full article

Full view

J. Krenkova, A. Gargano, N. A. Lacher, J. M. Schneiderheinze, F. Švec

Journal of Chromatography A, 1216 (2009) 6824–6830

Poly(glycidyl methacrylate-co-ethylene methacrylate) monoliths have been prepared in 100 μm i.d. capillaries and their epoxy groups hydrolyzed to obtain poly(2,3-dihydroxypropyl methacrylate-co-ethylene methacrylate) matrix. These polymers were then photografted in a single step with 2-acrylamido-2-methyl-1-propanesulfonic acid and acrylic acid to afford stationary phases for a strong and a weak cation exchange chromatography, respectively. Alternatively, poly(ethylene glycol) methacrylate was used for grafting in the first step in order to enhance hydrophilicity of the support followed by photografting with 2-acrylamido-2-methyl-1-propanesulfonic acid or acrylic acid in the second step. These new columns were used for the separation of proteins and peptides. A mixture of ovalbumin, α-chymotrypsinogen, cytochrome c, ribonuclease A and lysozyme was used to assess the chromatographic performance for large molecules while a cytochrome c digest served as a model mixture of peptides. All tested columns featured excellent mass transfer as demonstrated with very steep breakthrough curves. The highest binding capacities were found for columns prepared using the two step functionalization. Columns with sulfonic acid functionalities adsorbed up to 21.5 mg/mL lysozyme while the capacity of the weak cation exchange column functionalized with acrylic acid was 29.2 mg/mL.

Purchase full article

Full view

L. Urbas, P. Brne, B. Gabor, M. Barut, M. Strlič, T. Čerk Petrič, A. Štrancar

Joural of Chromatography A, 1216 (2009) 2689-2694

Human serum albumin (HSA) and immunoglobulin G (IgG) represent over 75% of all proteins present in human plasma. These high-abundance proteins prevent the detection of low-abundance proteins which are potential markers for various diseases. The depletion of HSA and IgG is therefore essential for further proteome analysis. In this paper we describe the optimization of conditions for selective depletion of HSA and IgG using affinity and pseudo-affinity chromatography. A Sartorius BIA Separations CIM (convective interaction media) Protein G disk was applied for the removal of IgG and the Mimetic Blue SA A6XL stationary phase for the removal of HSA. The binding and the elution buffer for CIM Protein G disk were chosen on the basis of the peak shape. The dynamic binding capacity was determined. It was shown to be dependent on the buffer system used and independent of the flow rate and of the concentration of IgG. Beside the binding capacity for the IgG standard, the binding capacity was also determined for IgG in human plasma. The Mimetic Blue SA A6XL column was characterized using human plasma. The selectivity of the depletion was dependent on the amount of human plasma that was loaded on the column. After the conditions on both supports had been optimized, the Mimetic Blue SA A6XL stationary phase was combined with the CIM Protein G disk in order to simultaneously deplete samples of human plasma. A centrifuge spin column that enables the removal of IgG and HSA from 20 μL of human plasma was designed. The results of the depletion were examined using sodium dodecyl sulfate polyacrylamide gel electrophoresis and two-dimensional gel electrophoresis.

Purchase full article

Full view

A. Tscheliessnig, D. Ong, J. Lee, S. Pan, G. Satianegara, K. Schriebl, A. Choo, A. Jungbauer

Journal of Chromatography A, 1216 (2009) 7851–7864

A two-step purification strategy comprising of polyethylene glycol (PEG) precipitation and anion-exchange chromatography was developed for a panel of monoclonal immunoglobulin M (IgM) (pI 5.5–7.7) produced from hybridoma cultures. PEG precipitation was optimized with regards to concentration, pH and mixing. For anion-exchange chromatography, different resins were screened of which Fractogel EMD, a polymer grafted porous resin had the highest capacity. Despite its significantly slower mass transfer, the binding capacity was still higher compared to a convection driven resin (monolith). This purification strategy was successfully demonstrated for all 9 IgMs in the panel. In small scale most antibodies could be purified to >95% purity with the exception of two which gave a lower final purity (46% and 85%). The yield was dependent on the different antibodies ranging from 28% to 84%. Further improvement of recovery and purity was obtained by the digestion of DNA present in the hybridoma supernatant using an endonuclease, benzonase. So far this strategy has been applied for the purification of up to 2 l hybridoma supernatants.

Purchase full article

Full view

K. Ralla, F. Anton, T. Scheper, C. Kasper

Journal of Chromatography A, 1216 (2009) 2671-2675

The aim of this study was to develop a chromatographic method, as a substitute for enzyme-linked immunosorbent assays, for the rapid and simultaneous detection of IgG, insulin, and transferrin present in a cell culture medium. Conjoint liquid chromatography (conjoint LC) using monolithic disks was applied for this purpose. An anion-exchange disk was combined with a Protein G affinity disk in a preparative HPLC system. IgG bound to the Protein G disk, whereas transferrin and insulin were captured on the quaternary ammonium (QA) disk. Using this method, it was possible to simultaneously determine the concentrations of IgG, transferrin, and insulin in the cell culture medium. Thus, conjoint LC could be used for the rapid and simultaneous detection of different proteins present in a cell culture medium.

Purchase full article

Full view

A. Tscheliessnig, A. Jungbauer

Journal of Chromatography A, 1216 (2009) 2676-2682

High-performance monolith affinity chromatography employing protein A resins has been introduced previously for the fast purification of IgG from different sources. Here we describe the design and evaluation of a fast and specific method for quantitation of IgG from purified samples as well as crude supernatant from Chinese hamster ovary (CHO) cells. We used a commercially available affinity monolith with protein A as affinity ligand (CIM protein A HLD disk). Interferences of CHO host cell proteins with the quantitation of IgG from CHO supernatant were eliminated by a careful choice of the equilibration buffer. With this method developed, it is possible to quantify IgG within 5 min in a concentration range of 23–250 μg/ml. The calibration range of the method could be extended from 4 to 1000 μg/ml by adjusting the injection volume. The method was successfully validated by measuring the low limit of detection and quantification, inter- and intra-day precision and selectivity.

Purchase full article

Full view

L. Urbas, P. Brne, B. Gabo, M. Barut, M. Strlič, T. Čerk Petrič, A. Štrancar

Journal of Chromatography A, 1216 (2009) 2689–2694

Human serum albumin (HSA) and immunoglobulin G (IgG) represent over 75% of all proteins present in human plasma. These high-abundance proteins prevent the detection of low-abundance proteins which are potential markers for various diseases. The depletion of HSA and IgG is therefore essential for further proteome analysis. In this paper we describe the optimization of conditions for selective depletion of HSA and IgG using affinity and pseudo-affinity chromatography. A Sartorius BIA Separations CIM (convective interaction media) Protein G disk was applied for the removal of IgG and the Mimetic Blue SA A6XL stationary phase for the removal of HSA. The binding and the elution buffer for CIM Protein G disk were chosen on the basis of the peak shape. The dynamic binding capacity was determined. It was shown to be dependent on the buffer system used and independent of the flow rate and of the concentration of IgG. Beside the binding capacity for the IgG standard, the binding capacity was also determined for IgG in human plasma. The Mimetic Blue SA A6XL column was characterized using human plasma. The selectivity of the depletion was dependent on the amount of human plasma that was loaded on the column. After the conditions on both supports had been optimized, the Mimetic Blue SA A6XL stationary phase was combined with the CIM Protein G disk in order to simultaneously deplete samples of human plasma. A centrifuge spin column that enables the removal of IgG and HSA from 20 μL of human plasma was designed. The results of the depletion were examined using sodium dodecyl sulfate polyacrylamide gel electrophoresis and two-dimensional gel electrophoresis.

Purchase full article

Full view

A. Tscheliessnig, A. Jungbauer

Journal of Chromatography A, 1216 (2009) 2676–2682

High-performance monolith affinity chromatography employing protein A resins has been introduced previously for the fast purification of IgG from different sources. Here we describe the design and evaluation of a fast and specific method for quantitation of IgG from purified samples as well as crude supernatant from Chinese hamster ovary (CHO) cells. We used a commercially available affinity monolith with protein A as affinity ligand (CIM protein A HLD disk). Interferences of CHO host cell proteins with the quantitation of IgG from CHO supernatant were eliminated by a careful choice of the equilibration buffer. With this method developed, it is possible to quantify IgG within 5 min in a concentration range of 23–250 μg/ml. The calibration range of the method could be extended from 4 to 1000 μg/ml by adjusting the injection volume. The method was successfully validated by measuring the low limit of detection and quantification, inter- and intra-day precision and selectivity.

Purchase full article

Full view

J. Krenkova, A. Gargano, N. A. Lacher, J. M. Schneiderheinze, F. Svec

Journal of Chromatography A, 1216 (2009) 6824–6830

Poly(glycidyl methacrylate-co-ethylene methacrylate) monoliths have been prepared in 100 μm i.d. capillaries and their epoxy groups hydrolyzed to obtain poly(2,3-dihydroxypropyl methacrylate-co-ethylene methacrylate) matrix. These polymers were then photografted in a single step with 2-acrylamido-2-methyl-1-propanesulfonic acid and acrylic acid to afford stationary phases for a strong and a weak cation exchange chromatography, respectively. Alternatively, poly(ethylene glycol) methacrylate was used for grafting in the first step in order to enhance hydrophilicity of the support followed by photografting with 2-acrylamido-2-methyl-1-propanesulfonic acid or acrylic acid in the second step. These new columns were used for the separation of proteins and peptides. A mixture of ovalbumin, α-chymotrypsinogen, cytochrome c, ribonuclease A and lysozyme was used to assess the chromatographic performance for large molecules while a cytochrome c digest served as a model mixture of peptides. All tested columns featured excellent mass transfer as demonstrated with very steep breakthrough curves. The highest binding capacities were found for columns prepared using the two step functionalization. Columns with sulfonic acid functionalities adsorbed up to 21.5 mg/mL lysozyme while the capacity of the weak cation exchange column functionalized with acrylic acid was 29.2 mg/mL.

Purchase full article

Full view

C. Delattre, M. A. Vijayalakshmi

Journal of Molecular Catalysis B: Enzymatic 60 (2009) 97–105

Recent research in the area of bioactive carbohydrates has shown the efficiency of oligosaccharides as signal molecules in a lot of biological activities. Newly observed functions of oligosaccharides and their abilities to act as specific regulatory molecules on various organisms have been more and more described. A successful development of these bioactive molecules in future needs efficient processes for specific oligosaccharides production. To exploit them for putative industrial scale up processes, two main strategies are currently investigated: the synthesis (chemical or bioconversion processes) and the polysaccharide cleavage (chemical, physical or biological processes). Nevertheless, if new manufacturing biotechnologies have considerably increased the development of these functional molecules, the main drawback limiting their biological applications is the complexity to engender specific glycosidic structures for specific activities. In the recent years, new enzymatic reactors have been developed, allowing the automatic synthesis of oligosaccharide structures. This review focuses on the knowledge in the area of bioactive oligosaccharides and gives the main processes employed to generate them for industrial applications with challenges of monolith microreactors.

Purchase full article

Full view

2008

P. Gagnon

MSS2008

When monoclonal antibodies were first beginning to be commercialized, expression levels over 100 mg/L were considered outstanding, and cell culture was viewed as the bottleneck in manufacturing productivity. Antibody expression levels now commonly exceed 1 g/L and reports of 10 and 15 g/L have been recently announced. Downstream processing is now considered the bottleneck.

In one sense, the bottleneck is artificial. Cell culture production takes about two weeks (not counting preparation of seed stock) and purification takes about a week. In another sense, the bottleneck is real, and a genuine concern. Process time for the protein A capture step from 20,000 L of cell culture supernatant (CCS) commonly requires 72-96 hours. This represents multiple cycles. The long hold time for IgG produced in the early cycles increases the risk of degradation by proteolysis, deamidation, etc. It also increases the risk of contamination.

Read full presentation

Full view

C. Delattre, P. Michaud, M. A. Vijayalakshmi

Journal of Chromatography B, 861 (2008) 203–208

Fast production and purification of α-(1,4)-oligogalacturonides was investigated using a new enzymatic reactor composed of a monolithic matrix. Pectin lyase from Aspergillus japonicus (Sigma) was immobilized on CIM-disk epoxy monolith. Studies were performed on free pectin lyase and immobilized pectin lyase to compare the optimum temperature, optimum pH, and thermal stability. It was determined that optimum temperature for free pectin lyase and immobilized pectin lyase on monolithic support is 30 °C, and optimum pH is 5. Monolithic CIM-disk chromatography is one of the fastest liquid chromatographic method used for separation and purification of biomolecules due to high mass transfer rate. In this context, online one step production and purification of oligogalacturonides was investigated associating CIM-disk pectin lyase and CIM-disk DEAE. This efficient enzymatic bioreactor production of uronic oligosaccharides from polygalacturonic acid (PGA) constitutes an original fast process to generate bioactive oligouronides.

Purchase full article

Full view

2007

K. Isobe, Y. Kawakami

Journal of Chromatography A, 1144 (2007) 85-89(2007) 85-89

A convection interaction media (trade name CIM, Sartorius BIA Separation, Ljubljana, Slovenia) isobutyl monolithic disc was prepared by incubating a CIM epoxy monolithic disc with isobutylamine, and it was then applied to the purification of secondary alcohol dehydrogenase (S-ADH) and primary alcohol oxidase (P-AOD). Both enzymes were adsorbed on this column and eluted with high purity. Thus, S-ADH was purified to an electrophoretically homogeneous state by four column chromatographies using CIM DEAE-8 and CIM C4-8 tube monolithic columns, blue-Sepharose column and CIM isobutyl disc monolithic column. P-AOD was also purified to an electrophoretically homogeneous state by three column chromatographies of CIM DEAE-8 tube, CIM C4-8 tube and CIM isobutyl disc columns.

Purchase full article

Full view

E. Müller, C. Mann

Journal of Chromatography A, 1144 (2007) 30-39(2007) 30-39

The electro-acoustic effects, namely the ion vibration potential (IVP) and the colloidal vibration current (CVI), colloidal vibration potential (CVP) first described by P. Debye [P. Debye, J. Chem. Phys. 1 (1933) 13], are a result of charge separation of bound or free ions at different degrees by ultrasonic waves. Today commercial instruments are available to investigate liquid homogeneous and heterogeneous systems. In the present paper the application of this technique for the characterization of salts, protein solutions and resins for biochromatography is shown and valuable information about resins can be derived in a short time. Various resins were investigated with the following results: (1) the CVI magnitude is dependent of several parameters (such as particle size distribution, volume fraction, density difference); (2) the CVI is influenced by the surface modification of the resins. Polymeric modifications decrease the value of CVI. The CVI is generally lower for high capacity resins; (3) the measurement of the electro-acoustic effects can be used to detect small changes in resins. The CVI is dependent of the amount of adsorbed protein in “native” and denatured state.

Purchase full article

Full view

I. V. Kalashnikova, N. D. Ivanova, T. G. Evseeva, A. Yu. Menshikova, E. G. Vlakh, T. B. Tennikova

Journal of Chromatography A, 1144 (2007) 40–47(2007) 40–47

The subject of this paper is an investigation of the peculiarities of dynamic adsorption behavior of nanoparticles. For this purpose, virus-mimicking synthetic particles bearing different proteins at their outer surface were specially constructed using two approaches, e.g. the cross-linking of proteins and modification of polystyrene microsphere surface by proteins. Two chromatographic modes, namely ion-exchange and affinity liquid chromatography on ultra-short monolithic columns [Convective Interaction Media (CIM) DEAE and CIM QA disks] have been used as a tool for dynamic adsorption experiments. Such parameters as maximum adsorption capacity and its dependence on applied flow rate were established and compared with those obtained for individual proteins. Similarly to individual proteins, it was shown that the maximum of adsorption capacity was not changed at different flow rates. In addition, the permeability of porous space of used monolithic sorbents appeared to be sufficient for efficient separation of large particles and quite similar to the well-studied process applied for individual proteins.

Purchase full article

Full view

I.Vovk, B. Simonovska

Journal of Chromatography B, 849 (2007) 337-343

The most abundant isoforms of tomato pectin methylesterase (PME; EC 3.1.1.11; Mr 26 kDa), polygalacturonase (PG; EC 3.2.1.15; PG1 with Mr 82 kDa) and a basic protein with Mr 42 kDa and unknown function were isolated from fresh tomato fruit by a fast chromatographic procedure on a Convective Interaction Media (CIM®) short monolithic disk column bearing carboxymethyl (CM) groups. The extraction of the targeted enzymes with 1.2 M NaCl solution was followed by precipitation with ammonium sulfate at 60% of saturation, solubilisation of the pellet in 0.5 M NaCl and fractionation using a linear gradient from 0 to 700 mM NaCl. Among six fractions five had PME activity and four had PG activity, while one fraction containing a pure protein with Mr 42 kDa with neither of these activities. Two concentrated fractions, one with PG and one with PME were further purified. A linear gradient from 0 to 500 mM NaCl with 20% CH3CN in the mobile phase was used for the PG fraction and two CM disks and a linear gradient from 0 to 200 mM NaCl were used for the PME fraction as a greater capacity was necessary in this case. From 4 kg of fresh tomato flesh we obtained 22 mg of purified PME, 1.8 mg of purified, active PG1, 13.5 mg of additional basic protein and a fraction with PG2 contaminated by a PME isoform. Carboxymethyl CIM disk short monolithic columns are convenient for semi-preparative and analytical work with tomato fruit pectolytic enzymes.

Purchase full article

Full view

N. Delmotte, U. Kobold, T. Meier, A. Gallusser, A. Strancar, C. G. Huber

Anal Bioanal Chem (2007) 389:1065–1074

Immunoadsorbers based on 2.0 × 6.0 mm i.d., epoxy-bearing, methacrylate-based monolithic disks were developed in order to target myoglobin and N-terminal pro-natriuretic peptide (NT-proBNP), two biomarkers involved in cardiovascular disease. In both cases, antibodies were successfully coupled to the polymeric disk material. The developed immunoadsorbers permitted the selective isolation of myoglobin and NT-proBNP from human serum. Myoglobin was successfully isolated and detected from serum samples at concentrations down to 250 fmol μL-1. However, the affinity of the antibodies was not sufficient for the analysis of low-concentration clinical samples. Frontal analysis of anti-NT-proBNP disks revealed the ability of the immunoadsorber to bind up to 250 pmol NT-proBNP, which is more than sufficient for the analysis of clinical samples. Anti-NT-proBNP disks showed good stability over more than 18 months and excellent batch-to-batch reproducibility. Moreover, anti-NT-proBNP disks permitted the isolation of NT-proBNP at concentrations down to 750 amol μL−1 in serum, corresponding to concentrations of strongly diseased patients. Using reversed-phase trapping columns, the detection of NT-proBNP eluted from immunoadsorbers by mass spectrometry was achieved for concentrations down to 7.8 fmol μL-1.

Purchase full article

Full view

I. Vovk, B. Simonovska

Journal of Chromatography A, 1144 (2007) 90-96(2007) 90-96

An improved cation-exchange chromatographic procedure on Convective Interaction Media (CIM, Sartorius BIA Separations, Ljubljana, Slovenia) short monolithic methacrylate disk columns was used for the isolation of salt-independent pectin methylesterase (PME; EC 3.1.1.11) isoform and endo-polygalacturonase PG1 (PG, EC 3.2.1.15) from ripe tomato fruit extract after studying the chromatographic conditions including type of disk, binding buffer, pH, eluent composition and different gradients. Between 10 and 20 μg of proteins gave reliable chromatograms. Both carboxymethyl (CM) and sulfonyl (SO3) disks were equally suitable for the fractionation of tomato extract using the new gradient, but only CM disk was appropriate for further purification of the PME and PG fractions, and provided fast and sharp separation of proteins. The isolation of pure PG1 could be achieved only by addition of 20% of acetonitrile to the mobile phase. About 200 μg of proteins were loaded at one chromatographic run at the fractionation and purification. Determination of the molecular weights of the separated proteins showed that dimer of salt-independent PME isoform was formed in concentrated solutions of the enzyme but dissociated upon dilution of the solution. From 6 kg of fresh tomato flesh, 28 mg of purified salt-independent PME, 12.5 mg of purified and active PG1 and 4 mg of PG2 fraction contaminated with salt-dependent PME isoform were obtained by means of semi-preparative chromatography on CIM disks.