On May 12th, the biaseparations.com website will be retired and migrated tosartorius.com.Learn moreabout our combined offering today!
2007

M. Bartolini, V. Cavrini, V. Andrisano

Journal of Chromatography A, 1144 (2007) 102–110

The aim of the present study was the application of a human AChE-CIM-IMER (enzyme reactor containing acetylcholinesterase immobilized on a monolithic disk) for the rapid evaluation of the thermodynamic and kinetic constants, and the mechanism of action of new selected inhibitors. For this application, human recombinant AChE was covalently immobilized onto an ethylenediamine (EDA) monolithic Convective Interaction Media (CIM) disk and on-line studies were performed by inserting this IMER into a HPLC system. Short analysis time, absence of backpressure, low nonspecific matrix interactions and immediate recovery of enzyme activity were the best characteristics of this AChE-CIM-IMER. Mechanisms of action of selected reversible inhibitors (tacrine, donepezil, edrophonium, ambenonium) were evaluated by means of Lineweaver–Burk plot analysis. Analyses were performed on-line by injecting increasing concentrations of the tested inhibitor and substrate and by monitoring the product peak area. AChE-CIM-IMER kinetic parameters (Kmapp and vmaxapp ) were derived as well as inhibitory constants (Kiapp of selected compounds. Moreover, noteworthy results were obtained in the application of the AChE-CIM-IMER to the characterization of the carbamoylation and decarbamoylation steps in pseudo-irreversible binding of carbamate derivatives (physostigmine and rivastigmine). AChE-CIM-IMER appeared to be a valid tool to determine simultaneously the kinetic constants in a reliable and fast mode. The obtained values were found in agreement with those obtained with the classical methods with the free enzyme. Furthermore, after inactivation by carbamates, activity could be fully recovered and the AChE-CIM-IMER could be reused for further studies. Results showed that the AChE-CIM-IMER is a valid tool not only for automated fast screening in the first phase of the drug discovery process but also for the finest characterization of the mode of action of new hit compounds with increased accuracy and reproducibility and with saving of time and materials.

Purchase full article

Full view

2006

M. Krajačić, J. Ivancic-Jelecki, D. Forčić, A. Vrdoljak, D. Škorić

Journal of Chromatography A, 1144 (2007) 111-119

Replicative double-stranded RNA (dsRNA) is useful in preliminary identification of Cucumber mosaic virus and its satellite RNA (satRNA). This plant pathogen complex yields sufficient quantity of the replicative RNA form that can be isolated by chromatography on chemically unmodified graded cellulose powder (CF-11). In this work, much faster and more efficient procedure using DEAE monoliths was developed in which dsRNA was separated from other species in total nucleic acids extract originating from the infected plant tissue. The developed chromatographic method revealed the pathogens’ presence in only 15 min, avoiding nucleic acid precipitation and electrophoretic analysis.

Purchase full article

Full view

2005

M. Barut, A. Podgornik, P. Brne, A. Štrancar

J. Sep. Sci. 2005, 28, 1876-1892

New therapeutics that are being developed rely more and more on large and complex biomacromolecules like proteins, DNA, and viral particles. Manufacturing processes are being redesigned and optimized both upstream and downstream to cope with the ever-increasing demand for the above target molecules. In downstream processing, LC still represents the most powerful technique for achieving high yield and high purities of these molecules. In most cases, however, the separation technology relies on conventional particle-based technology, which has been optimized for the purification of smaller molecules. New technologies are, therefore, needed in order to push the downstream processing ahead and into the direction that will provide robust, productive, and easy to implement methods for the production of novel therapeutics. New technologies include the renaissance of membranes, various improvements of existing technologies, but also the introduction of a novel concept – the continuous bed or monolithic stationary phases. Among different introduced products, Convective Interaction Media short monolithic columns (SMC) that are based on methacrylate monoliths exhibit some interesting features that make them attractive for these tasks. SMC can be initially used for fast method development on the laboratory scale and subsequently efficiently transferred to preparative and even more importantly to industrial scale. A brief historical overview of methacrylate monoliths is presented, followed by a short presentation of theoretical considerations that had led to the development of SMC. The design of these columns, as well as their scale-up to large units, together with the methods for transferring gradient separations from one scale to another are addressed. Noninvasive methods that have been developed for the physical characterization of various batches of SMC, which fulfill the regulatory requirements for cGMP production, are discussed. The applications of SMC for the separation and purification of large biomolecules, which demonstrate the full potential of this novel technology for an efficient downstream processing of biomolecules, are also presented.

Purchase full article

Full view

A. Podgornik, A. Štrancar

Biotechnology Annual Review, 11 (2005) 281-333

Modern downstream processing requires fast and highly effective methods to obtain large quantities of highly pure substances. Commonly applied method for this purpose is chromatography. However, its main drawback is its throughput since purification, especially of large molecules, requires long process time. To overcome this problem several new stationary phases were introduced, among which short layer monoliths show superior properties for many applications. The purpose of this review is to give an overview about short methacrylate monolithic columns commercialised under the trademark Convective Interaction Media® (CIM). Their unique properties are described from different perspectives, explaining reasons for their application on various areas. Approaches to prepare large volume methacrylate monolithic column are discussed and optimal solutions are given. Different examples of CIM monolithic column implementation are summarised in the last part of the article to give the reader an idea about their advantages.

Purchase full article

Full view

A. Jungbauer

Journal of Chromatography A, 1065 (2005) 3–12

Bioseparation processes are dominated by chromatographic steps. Even primary recovery is sometimes accomplished by chromatographic separation, using a fluidized bed instead of a fixed bed. In this review, the action principles, features of chromatography media regarding physical and chemical properties will be described. An attempt will be made to establish categories of different media. Characteristics for bioseparation are the large pores and particle sizes. To achieve sufficient capacity for ultralarge molecules, such as plasmids or nanoparticles, such as viruses monoliths are the media of choice. In these media, the mass transport is accomplished by convection, and thus, the low diffusivity can be overcome. Common to all modern chromatography media is the fast operation. There are examples where a residence time of less then 3 min, is sufficient to reach the full potential of the adsorbent.

Purchase full article

Full view

P. Krajnc, N. Leber, D. Štefanec, S. Kontrec, A. Podgornik

Journal of Chromatography A, 1065 (2005) 69-73(2005) 69 - 73

Poly(glycidyl methacrylate-co-ethyleneglycol dimethacrylate) monolithic supports were prepared by radical polymerisation of the continuous phase of water in oil high internal phase emulsions. Morphology of monolithic materials was studied by scanning electron microscopy and mercury intrusion porosimetry. The ratio of phase volume and the degree of crosslinking influenced the void size and pore size distribution of resulting polymers. Void sizes between 1 and 10 μm were observed and average pore sizes around 100 nm. Polymers with 60, 75, 80 and 90% pore volume were prepared and even samples with highest pore volume showed good mechanical stability. They were modified to bear weak-anion exchange groups and tested on the separation of standard protein mixture containing myoglobin, conalbumine and trypsin inhibitor. Good separation was obtained in a very short time similar to the separation obtained by commercial methacrylate monoliths. However, higher dispersion was observed. Bovine serum albumin dynamic binding capacity for monolith with 90% porosity was close to 9 mg/ml.

Purchase full article

Full view

N. Lendero, J. Vidič, P. Brne, A. Podgornik, A. Štrancar

Journal of Chromatography A, 1065 (2005) 29-38(2005) 29 - 38

The objective of this study was to develop a fast, simple, non-destructive, non-toxic and low-priced method for determining the amount of ionic groups on resins, since the conventional titration method fails to give proper results on methacrylate monoliths. After the column had been pre-saturated with a high concentration buffer solution, a low concentration buffer solution of the same pH value was pumped through the column. Measuring pH and absorbance, the profiles with a shape of typical break-through curve were obtained. It was shown that the time of the pH transient, which appeared under such conditions, could be used as a measure of the total ionic capacity of ion-exchange monolithic columns. The effect of the column length, linear velocity and varying concentrations of buffer solutions on the time of the pH transient was examined. The method was shown to be suitable for determining the amount of ionic groups on both anion and cation monolithic columns. In addition, it could also be applied to particle bed columns. The time of the pH transient and the protein dynamic binding capacity were also compared and it was concluded that for a given monolith the protein capacity can be derived from the data obtained by the new method.

Purchase full article

Full view

I. Mihelič, D. Nemec, A. Podgornik, T. Koloini

Journal of Chromatography A, 1065 (2005) 59-67(2005) 59 - 67

Pressure drop analysis in commercial CIM disk monolithic columns is presented. Experimental measurements of pressure drop are compared to hydrodynamic models usually employed for prediction of pressure drop in packed beds, e.g. free surface model and capillary model applying hydraulic radius concept. However, the comparison between pressure drop in monolith and adequate packed bed give unexpected results. Pressure drop in a CIM disk monolithic column is approximately 50% lower than in an adequate packed bed of spheres having the same hydraulic radius as CIM disk monolith; meaning they both have the same porosity and the same specific surface area. This phenomenon seems to be a consequence of the monolithic porous structure which is quite different in terms of the pore size distribution and parallel pore nonuniformity compared to the one in conventional packed beds. The number of self-similar levels for the CIM monoliths was estimated to be between 1.03 and 2.75.

Purchase full article

Full view

T. B. Tennikova, J. Reusch

Journal of Chromatography A, 1065 (2005) 13-17(2005) 13 - 17

The history of the development of short monolithic beds is described.

Purchase full article

Full view

J. Vidić, A. Podgornik, A. Štrancar

Journal of Chromatography A, 1065 (2005) 51-58(2005) 51-58

The influence of glass surface modification in order to determine strength of the monolith attachment was studied. Modification consists of pre-treatment of the glass with chemicals or boiling in deionized water, silanization and drying has been investigated on different types of glass. Amount of silane groups was determined by measurement of the contact angle between the glass surface and water drop. The highest values were found for soda–lime glass. Strength of the monolith attachment was established by pumping ethanol through the monolithic capillaries and measuring the pressure drop at which monolith was dislodged. Surprisingly, it was found that the critical part of the glass surface modification procedure is glass pre-treatment. Good results were obtained with glass boiled in water for 2.5 h or more.

Purchase full article

Full view

S. Yamamoto, A. Kita

Journal of Chromatography A, 1065 (2005) 45-50(2005) 45-50

Although linear salt gradient elution ion-exchange chromatography (IEC) of proteins is commonly carried out with relatively short columns, it is still not clear how the column length affects the separation performance and the economics of the process. The separation performance can be adjusted by changing a combination of the column length, the gradient slope and the flow velocity. The same resolution can be obtained with a given column length with different combinations of the gradient slope and the flow velocity. This results in different separation time and elution volume at the same resolution. Based on our previous model, a method for determining the separation time and the elution volume relationship for the same resolution (iso-resolution curve) was developed. The effect of the column length and the mass transfer rate on the iso-resolution curve was examined. A long column and/or high mass transfer rate results in lesser elution volume. The resolution data with porous bead packed columns and monolithic columns were in good agreement with the calculated iso-resolution curves. Although the elution volume can be reduced with increasing column length, the pressure drop limits govern the optimum conditions.

Purchase full article

Full view

K. Isobe, Y. Kawakami

Journal of Chromatography A, 1065 (2005) 129-134

Chromatography conditions for two types of convection interaction media (CIM) tube monolithic column, DEAE-8 and C4-8, were investigated using three enzymes from different microorganisms. The enzymes were adsorbed on a CIM DEAE-8 tube column under the same conditions as conventional DEAE columns. The CIM C4-8 tube column required a high concentration of ammonium sulfate compared to the conventional C4 column for adsorbing the enzymes. The separation of enzymes on the CIM tube column chromatography was not affected at flow rates between 0.15 and 1.25 volumes of the column per min. Both columns were successfully applied to the purification of enzymes from crude enzyme solution. Thus, both CIM tube monolithic columns proved useful in greatly reducing the purification time, and could be used at any stage of enzyme purification.

Purchase full article

Full view

I. Vovk, B. Simonovska, M. Benčina

Journal of Chromatography A, 1065 (2005) 121-128

One of the main forms of tomato pectin methylesterase (PME; EC 3.1.1.11) that is applicable to the food industry was isolated from fresh tomato fruit. The extraction of the PME isoenzymes involved washing the fresh tomato flesh with water in order to remove sugars and than solubilizing the enzymes with a diluted HCl solution at pH 1.6. The extract was then neutralized to pH 7.4 using buffer solution. After filtration, the solution was directly fractioned using Convective Interaction Media (CIM®) short monolithic disk column bearing sulfonyl (SO3) groups and using a linear gradient from 0 to 700 mM NaCl. The injection volume was 3 ml and the diameter of the column was 12 mm and length 3 mm. The isolated fractions were monitored for protein content and PME activity. The fraction with the targeted enzyme, which showed NaCl independent activity, was further purified and concentrated by ultrafiltration and finally purified by a second semi-preparative cation-exchange chromatography step using a CIM carboxymethyl (CM) disk monolithic column consisting of two disks and applying a step gradient. From 1 kg of fresh tomato fruits, 7.5 mg of purified PME with molecular mass estimated to be 26 000 by sodium dodecyl sulfate–polyacrylamide gel electrophoresis (SDS–PAGE) was obtained. A fraction with mixed PME and polygalacturonase activity was also obtained. Compared to the published procedures for the isolation and purification of PME from plant materials, this new procedure is much faster and more efficient. The potential application of CIM disk short monolithic columns in the analysis and semi-preparative extraction and isolation of the PME isoenzyme is presented.

Purchase full article

Full view

G. A. Platonova, T. B. Tennikova

Journal of Chromatography A, 1065 (2005) 75–81(2005) 75–81

High-performance monolithic disk affinity chromatography was applied to the investigation of formation of complexes between (1) complementary polyriboadenylic and polyribouridylic acids, e.g. poly(A) and poly(U), respectively, (2) poly(A) and synthetic polycation poly(allylamine), pAA. Polyriboadenylic acid and poly(allylamine) were immobilized on macroporous disks (CIM disks). Quantitative parameters of affinity interactions between macromolecules were established using frontal analysis at different flow rates.

Purchase full article

Full view

Y.-P. Lim, D. Josić, H. Callanan, J. Brown, D. C. Hixson

Journal of Chromatography A, 1065 (2005) 39–43(2005) 39–43

Epoxy-activated monolithic CIM disks seem to be excellent supports for immobilization of protein ligands. The potential use of enzymes, immobilized on monolithic disks for rapid preparative cleavage proteins in solution was investigated. Digestion of complex plasma proteins was demonstrated by using inter-alpha inhibitors with elastase, immobilized on epoxy-activated CIM disks. Recently, a monoclonal antibody against human inter-alpha inhibitor proteins (MAb 69.31) was developed. MAb 69.31 blocks the inhibitory activity of inter-alpha inhibitor proteins to serine proteases. These results suggest that the epitope defined by this antibody is located within or proximal to the active site of the inhibitor molecule. This antibody, immobilized on monolithic disk, was used for very rapid isolation of inter-alpha proteins. The isolated complex protein was used for enzymatic digestion and isolation of cleavage products, especially from inter-alpha inhibitor light chain to elucidate precisely the target sequence for MAb 69.31 by N-terminal amino acid sequencing. Bovine pancreatic elastase immobilized on monolithic disk cleaves inter-alpha inhibitor protein complex into small fragments which are still reactive with MAb 69.31. One of these proteolytic fragments was isolated and partially sequenced. It could be shown that this sequence is located at the beginning of two proteinase inhibitor domains of the inter-alpha inhibitor light chain (bikunin). Elastase immobilized on monolithic disk offers a simple and rapid method for preparative isolation of protease cleavage fragments. The immobilized enzyme is stable and still active after repeated runs. A partial or complete digestion can be achieved by varying the flow rate.

Purchase full article

Call

Send SMS

Add to Skype

You'll need Skype CreditFree via Skype

Full view

D. Forčić, K. Branovič Čakanič, J. Ivančič, R. Jug, M. Barut, A. Štrancar, R. Mazuran

Analytical Biochemistry 336 (2005) 273-278

Analysis of crude samples from biotechnological processes is often required to demonstrate that residual host cell impurities are reduced or eliminated during purification. Current knowledge suggests that a continuous-cell-line DNA can be considered a cellular contaminant rather than a significant risk factor requiring removal to extremely low levels. Anion-exchange chromatography is one of the most important methods used in the downstream processing and analysis of different biomolecules. In this article, an application using Convective Interaction Media monolithic columns to improve the detection of residual cellular DNA is described.

Purchase full article

Full view

S. Jerman, A. Podgornik, K. Cankar, N. Čadež, M. Skrt, J. Žel, P. Raspor

Journal of Chromatography A 1065 (2005) 107-113

The availability of sufficient quantities of DNA of adequate quality is crucial in polymerase chain reaction (PCR)-based methods for genetically modified food detection. In this work, the suitability of anion-exchange CIM (Convective Interaction Media; Sartorius BIA Separations, Ljubljana, Slovenia) monolithic columns for isolation of DNA from food was studied. Maize and its derivates corn meal and thermally pre-treated corn meal were chosen as model food. Two commercially available CIM disk columns were tested: DEAE (diethylaminoethyl) and QA (quaternary amine). Preliminary separations were performed with standard solution of salmon DNA at different pH values and different NaCl concentrations in mobile phase. DEAE groups and pH 8 were chosen for further isolations of DNA from a complex matrix—food extract. The quality and quantity of isolated DNA were tested on agarose gel electrophoresis, with UV-scanning spectrophotometry, and by amplification with real-time PCR. DNA isolated in this way was of suitable quality for further PCR analyses. The described method is also applicable for DNA isolation from processed foods with decreased DNA content. Furthermore, it is more effective and less time-consuming in comparison with the existing proposed methods for isolation of DNA from plant-derived foods.

Purchase full article

Full view

D. Forčić, K. Branović-Čakanić, J. Ivančić, R. Jug, M. Barut, A. Štrancar

Journal of Chromatography A 1065 (2005) 115-120

The isolation and purification of nucleic acids is essential for many procedures in molecular biology. After showing that bacterial and eukaryotic genomic DNA can be specifically bound to the CIM DEAE monolithic column, this characteristic was exploited in development of a simple and fast chromatographic procedure for isolation and purification of genomic DNA from cell lysates that does not include the usage of toxic organic solutions. The purity and the quality of the isolate as well as the duration of the procedure was similar to other chromatographic methods used today for isolation of genomic DNA, but the initial sample volume was not restricted.

Purchase full article

Full view

J. Urthaler, R. Schlegl, A. Podgornik, A. Štrancar, A. Jungbauer, R. Necina

Journal of Chromatography A 1065 (2005) 93-106

The demand of high-purity plasmid DNA (pDNA) for gene-therapy and genetic vaccination is still increasing. For the large scale production of pharmaceutical grade plasmids generic and economic purification processes are needed. Most of the current processes for pDNA production use at least one chromatography step, which always constitutes as the key-step in the purification sequence. Monolithic chromatographic supports are an alternative to conventional supports due to their excellent mass transfer properties and their high binding capacity for pDNA. Anion-exchange chromatography is the most popular chromatography method for plasmid separation, since polynucleotides are negatively charged independent of the buffer conditions. For the implementation of a monolith-based anion exchange step into a pDNA purification process detailed screening experiments were performed. These studies included supports, ligand-types and ligand-densities and optimization of resolution and productivity. For this purpose model plasmids with a size of 4.3 and 6.9 kilo base pairs (kbp) were used. It could be shown, that up-scaling to the production scale using 800 ml CIM Convective Interaction Media radial flow monoliths is possible under low pressure conditions. CIM DEAE was successfully implemented as intermediate step of the cGMP pDNA manufacturing process. Starting from 200 l fermentation aliquots pilot scale purification runs were performed in order to prove scale-up and to predict further up-scaling to 8 l tube monolithic columns. The analytical results obtained from these runs confirmed suitability for pharmaceutical applications.

Purchase full article

Full view

M. Peterka, P. Kramberger, A. Štrancar

WANG, Perry G. (ur.). Monolithic chromatography and its modern applications. St Albans: ILM publications, 2010, pg. 489-508

Downstream processing (DSP) for purification can become a significant bottleneck in the production of novel biotherapeutics, such as viral vectors and vaccines (viral or DNA). Although different techniques can be used for the purification of large molecules and particles, liquid chromatography is the preferred method as it achieves the purity required by regulatory agencies. Despite the popularity of conventional chromatographic media, the diffusional mass transfer of large molecules and relatively small pore size remain limiting factors for the efficient separation of large biomolecules and particles. Methacrylate monoliths are a single-piece chromatographic support that consists of a highly porous material with an interconnected network of channels. The transport mechanism is predominantly based on convection, which allows rapid mass transfer between the mobile and stationary phase and so results in short separation times. Additionally, most of the active sites are located in the open, large channel structure and are therefore easily accessible, which results in a high DBC (DBC) for large molecules and viral particles. These characteristics make methacrylate monoliths an ideal chromatographic support for the separation and purification of extremely large molecules, such as large proteins, different types of DNA and virus particles.

Full view