On May 12th, the biaseparations.com website will be retired and migrated tosartorius.com.Learn moreabout our combined offering today!
2020

by Simon Staubach, Pete Gagnon, Katja Vrabec, Tjaša Lojpur, Sebastijan Peljhan, Bernd Giebel and Aleš Štrancar

BioProcess International, 2020

Abstract:

The traditional classification of extracellular vesicles (EVs) includes three types: exosomes, microvesicles, and apoptotic vesicles. Each type arises from a distinct origin and exhibits distinct characteristics. The problem is that their size ranges overlap and that the major surface proteins presented by exosomes also are present on the surfaces of microvesicles and apoptotic bodies. This makes it a challenge for process developers to identify the vesicle fraction that best serves a particular exosome therapy. Anion-exchange chromatography (AEC) can fractionate EVs into populations of different composition. This article highlights the complementarity of two analytical methods for characterizing distinctions among EV populations separated by AEC: imaging flow cytometry (IFCM) and size-exclusion chromatography.

Download full eBook

Full view

by Maribel Rios, Aleš Štrancar, J. Michael Hatfield and Pete Gagnon

BioProcess International, 2020

Abstract:

Adenoassociated viral (AAV) vectors have become synonymous with gene therapy delivery. However, because they are produced in such small quantities and because their upstream processes carry comparatively large amounts of host-cell DNA and other impurities, AAV purification can be challenging. Several researchers have applied different chromatographic strategies, but no universal method has been adopted in the biopharmaceutical industry.

This eBook features a discussion among several industry experts that explores challenges specific to AAV purification, shedding light on whether current strategies and separation technologies are up to the task. The conversation traverses issues relating to material handling at the upstream–downstream interface, removal of host-cell DNA, chromatographic separation of empty and full capsids, and a lack of fast and robust in-process analytics for downstream processes. Participants also explore whether the rise of AAV-based treatments will require downstream scientists to shift away from the antibody-centered conceptions of chromatography that have grown alongside the biotherapeutics industry.

Dowload full eBook

Full view

E. Multia, T. Liangsupree, M. Jussila, J. Ruiz-Jimenez, M. Kemell and M. Riekkola

Analytical Chemistry, 2020

Abstract:

An automated on-line isolation and fractionation system including controlling software was developed for selected nanosized biomacromolecules from human plasma by on-line coupled immunoaffinity chromatography asymmetric flow field-flow fractionation (IAC-AsFlFFF). The on-line system was versatile, only different monoclonal antibodies, anti-apolipoprotein B-100, anti-CD9, or anti-CD61, were immobilized on monolithic disk columns for isolation of lipoproteins and extracellular vesicles (EVs). The platelet-derived CD61-positive EVs and CD9-positive EVs, isolated by IAC, were further fractionated by AsFlFFF to their sizebased subpopulations (e.g., exomeres and exosomes) for further analysis. Field-emission scanning electron microscopy elucidated the morphology of the subpopulations, and 20 free amino acids and glucose in EV subpopulations were identified and quantified in the ng/mL range using hydrophilic interaction liquid chromatography-tandem mass spectrometry (HILIC-MS/MS). The study revealed that there were significant differences between EV origin and size-based subpopulations. The on-line coupled IAC-AsFlFFF system was successfully programmed for reliable execution of 10 sequential isolation and fractionation cycles (37−80 min per cycle) with minimal operator involvement, minimal sample losses, and contamination. The relative standard deviations (RSD) between the cycles for human plasma samples were 0.84−6.6%.

Attachments

Full view

M. Morani, T.Duc Mai, Z. Krupova, P. Defrenaix, E. Multia, M. Riekkola, M. Taverna

Analytica Chimica Acta 1128 (2020) 45-51

Abstract

This work reports on the development of the first capillary electrophoresis methodology for the elucidation of extracellular vesicles’ (EVs) electrokinetic distributions. The approach is based on capillary electrophoresis coupled with laser-induced fluorescent (LIF) detection for the identification and quantification of EVs after their isolation. Sensitive detection of these nanometric entities was possible thanks to an ‘inorganic-species-free’ background electrolyte. This electrolyte was made up of weakly charged molecules at very high concentrations to stabilize EVs, and an intra-membrane labelling approach was used to prevent EV morphology modification. The limit of detection for EVs achieved using the developed CE-LIF method method reached 8 × 10⁹ EVs/mL, whereas the calibration curve was acquired from 1.22 × 10¹⁰ to 1.20 × 10¹¹ EVs/mL. The CE-LIF approach was applied to provide the electrokinetic distributions of various EVs of animal and human origins, and visualize different EV subpopulations from our recently developed high-yield EV isolation method.

Purchase full article

Full view

Pete Gagnon, Katja Vrabec, Tjaša Lojpur, and Aleš Štrancar

BioProcess International, 18 (4) April 2020

Abstract

Exosomes are a subject of rapidly growing therapeutic interest in the biopharmaceutical industry for two principal reasons. The first reason is that they are the primary communicators of instructions from source cells to target cells. Exosome surface features define their destination. They recognize complementary features on target cells, dock with them, and deliver their programmed instructions in the form of microRNA. The second reason is that exosomes are immunologically silent. As normal human cell products, and by contrast with gene therapy vectors such as virus particles, exosomes bypass the issue of triggering an immune response that might interfere with therapy.

Source cells include stem cells, which is why exosomes are of particular interest in the field of regenerative medicine. Recent research documenting the ability of exosomes to reverse the effects of severe strokes highlights their potential. It also underlines the need for scalable purification technology to advance these products through clinical trials and on to licensed manufacture. A platform approach was a major factor in the initial and continuing success of monoclonal antibodies. Exosomes likewise represent an extended family of individual products with similar properties. It stands to reason that a platform approach will prove equally valuable for exosomes. In this article we describe initial efforts toward that goal.

Contact us and request full article

Full view

2019

Wang Chunlei, Mulagapati Sri Hari Raju, Chen Zhongying, Du Jing, Zhao Xiaohui, Xi Guoling, Chen Liyan, Linke Thomas, Gao Cuihua, Schmelzer Albert, Liu Dengfeng

Molecular Therapy  Methods & Clinical Development, Volume 15, September 26 2019, Pages 257-263

Abstract

Adeno-associated virus (AAV) vectors are clinically proven gene delivery vehicles that are attracting an increasing amount of attention. Non-genome-containing empty AAV capsids are by-products during AAV production that have been reported to potentially impact AAV product safety and efficacy. Therefore, the presence and amount of empty AAV capsids need to be characterized during process development. Multiple methods have been reported to characterize empty AAV capsid levels, including transmission electron microscopy (TEM), analytical ultracentrifugation (AUC), charge detection mass spectrometry (CDMS), UV spectrophotometry, and measuring capsid and genome copies by ELISA and qPCR. However, these methods may lack adequate accuracy and precision or be challenging to transfer to a quality control (QC) lab due to the difficulty of implementation. In this study, we used AAV serotype 6.2 (AAV6.2) as an example to show the development of a QC-friendly anion exchange chromatography (AEX) assay for the determination of empty and full capsid percentages. The reported assay requires several microliters of material with a minimum titer of 5 × 1011 vg/mL, and it can detect the presence of as low as 2.9% empty capsids in AAV6.2 samples. Additionally, the method is easy to deploy, can be automated, and has been successfully implemented to support testing of various in-process and release samples.

Read full article

Keywords: AAV, AAV6.2, Chromatography, Anion exchange chromatography (AEC), Empty capsids, AUC, High-throughput

Full view

Sofiya Fedosyuk, Thomas Merritt, Marco Polo Peralta-Alvarez, Susan J. Morris, Ada Lam, Nicolas Laroudie, Anilkumar Kangokar, Daniel Wright, George M. Warimwe, Phillip Angell-Manning, Adam J. Ritchie, Sarah C. Gilbert, Alex Xenopoulos, Anissa Boumlic, Alexander D. Douglas

Vaccine (2019).
Published online 30 April 2019.

A variety of Good Manufacturing Practice (GMP) compliant processes have been reported for production of non-replicating  adenovirus vectors, but important challenges remain. There is a need for rapid production platforms for small GMP batches of non-replicating adenovirus vectors for early-phase vaccine trials, particularly in preparation for response to emerging pathogen outbreaks. Such platforms must be robust to variation in the transgene, and ideally also capable of producing adenoviruses of more than one serotype. It is also highly desirable for such processes to be readily implemented in new facilities using  commercially available single-use materials, avoiding the need for development of bespoke tools or cleaning validation, and for them to be readily scalable for later-stage studies.
Here we report the development of such a process, using single-use stirred-tank bioreactors, a transgene-repressing HEK293 cell – promoter combination, and fully single-use filtration and ion exchange components. We demonstrate applicability of the process to candidate vaccines against rabies, malaria and Rift Valley fever, each based on a different adenovirus serotype.

Keywords: Simian adenovirus, GMP, Clinical trials, Single-use, Biomanufacturing, Bioreactor, Purification

Read full article

Full view

Evgen Multia, Crystal Jing Ying Tear, Mari Palviainen, Pia Siljander, Marja-Liisa Riekkola

Analytica Chimica Acta (2019).
Published online 2019 Sep 11.

A new, fast and selective immunoaffinity chromatographic method including a methacrylate-based convective interaction media (CIM®) disk monolithic column, immobilized with anti-human CD61 antibody, was developed for the isolation of CD61-containing platelet-derived extracellular vesicles (EVs) from plasma. The isolated EVs were detected and size characterized by asymmetrical flow field-flow fractionation (AsFlFFF) with multi-angle light-scattering (MALS) and dynamic light-scattering (DLS) detection, and further confirmed by nanoparticle tracking analysis (NTA) and transmission electron microscopy (TEM). The isolation procedure took only 19 min and the time can be even further decreased by increasing the flow rate. The same immunoaffinity chromatographic procedure, following AsFlFFF allowed also the isolation and characterization of platelet-derived EVs from plasma in under 60 min. Since it is possible to regenerate the anti-CD61 disk for multiple uses, the methodology developed in this study provides a viable substitution and addition to the conventional EV isolation procedures.

Keywords: Immunoaffinity chromatography, Isolation, Monolithic disk column, Extracellular vesicles, Platelet-derived vesicles, CD61

Read full article

Full view

Dr. Xiaotong Fu, Dr. Wei-Chiang  Chen, C. Argento, R. Dickerson, P. Clarner, V. Bhatt, G. Bou-Assaf, Dr. M. Bakhshayeshi, Dr. Xiaohui Lu, Dr. S. Bergelson, Dr. J. Pieracci

Human Gene Therapy (2019)

Recombinant adeno-associated virus (rAAV)-mediated gene therapy is a fast-evolving field in the biotechnology industry. One of the major challenges in developing a purification process for AAV gene therapy is establishing an effective yet scalable method to remove empty capsids, or viral vectors lacking the therapeutic gene, from full capsids—viral product containing the therapeutic sequence. Several analytical methods that can quantify the empty-to-full capsid ratio have been reported in the literature. However, as samples can vary widely in viral titer, buffer matrix, and the relative level of empty capsids, understanding the specifications and limitations of different analytical methods is critical to providing appropriate support to facilitate process development. In this study, we developed a novel anion-exchange high-performance liquid chromatography (AEX-HPLC) assay to determine the empty-to-full capsid ratio of rAAV samples. The newly developed method demonstrated good comparability to both the transmission electron microscopy (TEM) and analytical ultracentrifugation (AUC) methods used in empty-to-full capsid ratio quantification, yet providing much higher assay throughput and reducing the minimum sample concentration requirement to 2.7E11 viral genomes (vg)/ml.

Purchase full article

Full view

K. Trabelsi, M. Ben Zakour, H. Kallel

Vaccine (2019)

Rabies is a viral zoonosis caused by negative-stranded RNA viruses of the Lyssavirus genus. It can affect all mammals including humans. Dogs are the main source of human rabies deaths, contributing up to 99% of all rabies transmissions to humans. Vaccination against rabies is still the sole efficient way to fight against the disease.
Cell culture vaccines are recommended by World Health Organization (WHO) for pre and post exposure prophylaxis; among them Vero cell rabies vaccines which are used worldwide. In this work we studied the purification of inactivated rabies virus produced in Vero cells grown in animal component free conditions, using different methods. Cells were grown in VP-SFM medium in stirred bioreactor, then infected at an MOI of 0.05 with the LP2061 rabies virus strain. Collected harvests were purified by zonal centrifugation, and by chromatography supports, namely the Capto Core 700 and the monolithic CIM-QA column. Generated data were compared in terms of residual DNA level, host cell proteins (HCP) level and the overall recovery yield.
 

Purchase full article

Full view

This discussion introduces new analytical approaches that enable in-line chromatographic detection of exosomes. One approach can discriminate extracellular vesicles from nonvesicle contaminants, and one potentially can discriminate exosomes from other vesicles. Examples illustrate how they enable development of more effective and better documented purification methods. The special qualifications of monolithic chromatography media for exosome purification are discussed. New process tools designed to accommodate some of the special challenges of exosome purification are introduced.

Feel free to download the eBook by clicking on the link to attachment below.

Attachments

Full view

2018

M. Tajnik Sbaizero, M. Wolschek, M. Reiter, T. Muster, Pete Gagnon and Aleš Štrancar

BioProcess International, 15 October 2018

Influenza is a global respiratory disease with an estimated mortality of up to a half million people per year. The majority of traditional influenza vaccines are still produced in eggs. Downstream processing typically consists of clarification by centrifugation, concentration by ultrafiltration, and purification by ultracentrifugation. Recombinant vaccines are most often purified by chromatography. Chromatographic purification of viruses already has achieved major improvements in recovery and scalability, but it also is important because it enables virus purification to keep pace with important regulatory and manufacturing trends across the field of biopharmaceuticals. One of those trends is process intensification, referring to development of processes that harmonize integration of fewer and more capable steps to achieve higher productivity and reproducibility as well as reduce manufacturing costs.
In this report we describe processes for purification of influenza A and influenza B, both lacking TFF steps, and both using a single chromatography step with a cation exchange monolith on a single-use basis. The choice of process buffers enables final formulation by simple dilution of the product pool. DNA digestion requires two hours. Capture, purification, and formulation are achieved within four hours. Host-cell DNA and host-cell protein (HCP) are reduced more than 99%, and final virus recovery is 80%.

Download full article

Full view

Laura M. Fischer, Michael W. Wolff, Udo Reichl, Vaccine 2017 July 17

The continuously increasing demand for potent and safe vaccines and the intensifying economic pressure on health care systems underlines the need for further optimization of vaccine manufacturing. Here, we focus on downstream processing of human influenza vaccines, investigating the purification of serum free cell culture-derived influenza virus (A/PR/8/34 H1N1) using continuous chromatography. Therefore, quaternary amine anion exchange monoliths (CIM QA) were characterized for their capacity to capture virus particles from animal cells cultivated in different media and their ability to separate virions from contaminating host cell proteins and DNA. The continuous chromatography was implemented as simulated moving bed chromatography (SMB) in a three zone open loop configuration with a detached high salt zone for regeneration.
SMBs exploiting 10% and 50% of the monoliths’ dynamic binding capacity, respectively, allowed the depletion of >98% of the DNA and >52% of the total protein. Based on the hemagglutination assay (HA assay), the virus yield was higher at 10% capacity use (89% vs. 45%). Both SMB  separations resulted in a ratio of total protein to hemagglutinin antigen (based on single radial diffusion assay, SRID assay) below the required levels for manufacturing of human vaccines (less than 100 mg of protein per virus strain per dose). The level of contaminating DNA was five-times lower for the 10% loading, but still exceeded the required limit for human vaccines. A subsequent Benzonase treatment step, however, reduced the DNA contamination below 10 ng per dose. Coupled to continuous cultivations for virus propagation, the establishment of integrated processes for fully continuous production of vaccines seems to be feasible.

Download full article

Full view

Tsutomu Arakawa, Pete Gagnon

Journal of Pharmaceutical Sciences 107 (2018) 2297-2305

The concept of cosolvent exclusion was developed by a group of Timasheff's laboratory in 1970-1990 and is currently used widely to explain the effects of a variety of cosolvents on the stability and solubility of macromolecules. Not surprisingly, these concepts have had substantial influence in the fields of formulation, protein folding and unfolding, but they have perhaps more surprisingly found their way into the field of chromatography. A variety of excluded cosolvents have been used to enhance binding and resolution of proteins and other macromolecules in ion exchange, hydroxyapatite, affinity, and hydrophobic interaction chromatography. These cosolvents include salting-out salts, amino acids and polymers, and frequently polyethylene glycol (PEG). A new mode of chromatography, termed “steric exclusion chromatography,” was recently introduced. It employs hydroxylated solid phase surfaces. Steric exclusion of the PEG stabilizes the association of macromolecules with the solid phase. Elution is achieved by reducing the PEG concentration. Magnetic particles are also used in this chromatography. This review summarizes the concepts of preferential cosolvent exclusion and its applications in column chromatography.

Purchase full article or request a copy at sales@biaseparations.com

Full view

2017

V.Rajamanickam, D.Wurm, C.Slouka, C.Herwig, O.Spadiut

Anal Bioanal Chem (2016)

The bacterium Escherichia coli is a well-studied recombinant host organism with a plethora of applications in biotechnology. Highly valuable biopharmaceuticals, such as antibody fragments and growth factors, are currently being produced in E. coli. However, the high metabolic burden during recombinant protein production can lead to cell death, consequent lysis, and undesired product loss. Thus, fast and precise analyzers to monitor E. coli bioprocesses and to retrieve key process information, such as the optimal time point of harvest, are needed. However, such reliable monitoring tools are still scarce to date. In this study, we cultivated an E. coli strain producing a recombinant single-chain antibody fragment in the cytoplasm. In bioreactor cultivations, we purposely triggered cell lysis by pH ramps. We developed a novel toolbox using UV chromatograms as fingerprints and chemometric techniques to monitor these lysis events and used flow cytometry (FCM) as reference method to quantify viability offline. Summarizing, we were able to show that a novel toolbox comprising HPLC chromatogram fingerprinting and data science tools allowed the identification of E. coli lysis in a fast and reliable manner. We are convinced that this toolbox will not only facilitate E. coli bioprocess monitoring but will also allow enhanced process control in the future

Purchase full article

Full view

Alicia T Lucero, Sergio A Mercado, Anamaría C Sánchez,Carolina A Contador, Barbara A Andrews and Juan A Asenjo, Journal of chemical technology and biotechnology, (2017)

BACKGROUND: Gene therapy is a potent alternative for long-lasting inhibition of alcohol consumption. This study compares the purification of a recombinant adenoviral vector serotype 5 (rAdV5) for use in gene therapy against alcoholism using two anion-exchange methods.

RESULTS: Two anion-exchange chromatography methods using fast protein liquid chromatography were compared using a packed-bed column (Q-Sepharose™ XL) and two monolithic columns (CIM™ QA-1 and CIM™ DEAE-1). An improved and reproducible separation of recombinant adenovirus type 5 from cell lysate contaminants was achieved using the two strong anion-exchange columns in a two-step gradient chromatography. Higher adenovirus yields were achieved using the CIM QA-1 tube monolithic column at sample volumes of both 1 and 10 mL compared with the Q-Sepharose XL column. At higher flow rates, the CIM QA-1 tube monolithic column achieved better separation of the target fraction. Process recovery was improved from 28% using the Q-Sepharose XL column to 34% with the CIM QA-1 tube monolithic column quantified as vector genome. Analysis by SDS-PAGE demonstrated a purity of 70% for purified adenovirus using the CIM QA-1 tube monolithic column.

CONCLUSION: This study indicated that the use of a CIM QA-1 tube monolithic column is a better alternative than Q-Sepharose XL, and CIM DEAE-1 tube monolithic columns for the primary purification process of rAdV5 carrying the human aldehyde dehydrogenase-2 antisense gene. This purification strategy has been used as a basis to scale-up a GLP process for the production of material at the National Research Council of Canada to be used in preclinical trials of this gene therapy against alcoholism

Download full article

Full view

Sebastijan Peljhan, Tina Jakop, Dunja Šček, Vid Skvarča, Blaž Goričar, Romina Žabar, Nina Mencin. Electrophoresis 2017 July 20

The plasma-derived IgG used either for diagnostic purpose or intravenous application (in form of IVIG) in various medical therapies is certainly gaining more and more attention on annual basis. Different manufacturing processes are used to isolate immunoglobulins from human plasma. However, a quest for alternative paths in IgG isolation not only requires development of the most efficient isolation process, but also a rapid and reliable analytics to track the purification. Fast and reliable fingerprint based method for characterization of IgG prepared from Cohn I+II+III paste is presented in this paper. The fingerprint method bases on partial separation of proteins in linear gradient on CIMacTM quaternary amine, strong anion exchange group (QA) 0.1 mL column. Partial separation of proteins does not allow simple quantitative analysis of the samples during the IgG isolation from Cohn I+II+III fraction paste, but very accurate qualitative information about the composition of the sample can be obtained in less than 5 min. From the differences in the chromatograms of various samples, the ratio between IgG and impurities in each sample can be easily assessed. The method is suitable for input material control, in-line monitoring of the downstream processing, final control of the products, as well as in stability studies and enables taking fast and accurate decisions during fractionation process.

 Purchase full article.

Full view

David Vincent, Petra Kramberger, Rosana Hudej, Aleš Štrancar, Yaohe Wang,Yuhong Zhou, Ajoy Velayudhan

The purification of large viruses remains an important field of research and development. The development of efficient purification trains is limited by limited analytical methods, as well as by the complexity of large viruses, as well as the high variability in starting material from cell culture. Vaccinia virus holds great potential as an oncolytic and immunotherapeutic vaccine against a broad spectrum of cancers. In this work, monolith-based capture and polishing chromatographic steps for vaccinia virus Lister strain has been developed. Virus produced in CV-1 cells was harvested and passed through a 0.8μm pre-filter before loading onto CIEX, AIEX and HIC CIM monoliths. Without the need for nuclease treatment, up to 99% of the total DNA loaded can be removed from the vaccinia feed stream by the CIM OH monolith, which also reduces the total protein concentration in the product pool to LLOQ levels, and achieves infectious virus recoveries of 90%. Binding capacities of greater than 1x109 pfu of vaccinia per mL of matrix were obtained on both CIM SO3 and CIM OH monoliths. Multiple orthogonal analytical methods have been used to develop process knowledge and understanding.

Attachments

Full view

Antonio M. Munoz, Paul Yourik, Vaishnavi Rajagopal, Jagpreet S. Nanda, Jon R. Lorsch, Sarah E. Walker

RNA Biology, 2017, VOL. 14, NO. 2, 188–196

In vitro studies of translation provide critical mechanistic details, yet purification of large amounts of highly active eukaryotic ribosomes remains a challenge for biochemists and structural biologists. Here, we present an optimized method for preparation of highly active yeast ribosomes that could easily be adapted for purification of ribosomes from other species. The use of a nitrogen mill for cell lysis coupled with chromatographic purification of the ribosomes results in 10-fold-increased yield and less variability compared with the traditional approach, which relies on sedimentation through sucrose cushions. We demonstrate that these ribosomes are equivalent to those made using the traditional method in a host of in vitro assays, and that utilization of this new method will consistently produce high yields of active yeast ribosomes.

Attachments

Full view

2016

P. Stepperta, D. Burgstallera, M. Klausbergera, E. Bergerb, P.P. Aguilara, T.A. Schneiderb, P. Krambergerc, A. Toverd,  K. Nöbauere, E. Razzazi-Fazelie, A. Jungbauer, Journal of Chromatography A, 1455 (2016)

Enveloped virus-like particles (VLPs) are increasingly used as vaccines and immunotherapeutics. Frequently, very time consuming density gradient centrifugation techniques are used for purification ofVLPs. However, the progress towards optimized large-scale VLP production increased the demand for fast, cost efficient and scaleable purification processes. We developed a chromatographic procedure for purification of HIV-1 gag VLPs produced in CHOcells. The clarified and filtered cell culture supernatant was directly processed on an anion-exchange monolith. The majority of host cell impurities passed throughthe column, whereas the VLPs were eluted by a linear or step salt gradient; the major fraction of DNA waseluted prior to VLPs and particles in the range of 100–200nm in diameter could be separated into two fractions. The earlier eluted fraction was enriched with extracellular particles associated to exosomes or microvesicles, whereas the late eluting fractions contained the majority of most pure HIV-1 gag VLPs. DNA content in the exosome-containing fraction could not be reduced by Benzonase treatment which indicated that the DNA was encapsulated. Many exosome markers were identified by proteomic analysisin this fraction. We present a laboratory method that could serve as a basis for rapid downstream processing of enveloped VLPs. Up to 2000 doses, each containing 1×109 particles, could be processed witha 1mL monolith within 47 min. The method compared to density gradient centrifugation has a 220-fold improvement in productivity.

Download full article

Full view