On May 12th, the biaseparations.com website will be retired and migrated tosartorius.com.Learn moreabout our combined offering today!
2020

E. Multia, T. Liangsupree, M. Jussila, J. Ruiz-Jimenez, M. Kemell and M. Riekkola

Analytical Chemistry, 2020

Abstract:

An automated on-line isolation and fractionation system including controlling software was developed for selected nanosized biomacromolecules from human plasma by on-line coupled immunoaffinity chromatography asymmetric flow field-flow fractionation (IAC-AsFlFFF). The on-line system was versatile, only different monoclonal antibodies, anti-apolipoprotein B-100, anti-CD9, or anti-CD61, were immobilized on monolithic disk columns for isolation of lipoproteins and extracellular vesicles (EVs). The platelet-derived CD61-positive EVs and CD9-positive EVs, isolated by IAC, were further fractionated by AsFlFFF to their sizebased subpopulations (e.g., exomeres and exosomes) for further analysis. Field-emission scanning electron microscopy elucidated the morphology of the subpopulations, and 20 free amino acids and glucose in EV subpopulations were identified and quantified in the ng/mL range using hydrophilic interaction liquid chromatography-tandem mass spectrometry (HILIC-MS/MS). The study revealed that there were significant differences between EV origin and size-based subpopulations. The on-line coupled IAC-AsFlFFF system was successfully programmed for reliable execution of 10 sequential isolation and fractionation cycles (37−80 min per cycle) with minimal operator involvement, minimal sample losses, and contamination. The relative standard deviations (RSD) between the cycles for human plasma samples were 0.84−6.6%.

Attachments

Full view

P. Gagnon, B. Goričar, Š. Peršič, U. Černigoj, A. Štrancar

Cell & Gene Therapy Insights 2020; 6(7), 1035–1046

Abstract:

One of the barriers to development of industrial purification platforms for large mRNA has been an inadequate selection of high-performing capture-purification tools. Hybridization-affinity uses a polythymidine (Oligo dT) ligand to base-pair with the polyadenine tail of mRNA. It can be used for capture but it cannot discriminate dsRNA (double-stranded) from ssRNA (single-stranded) and it supports only brief cleaning with 100 mM sodium hydroxide. Traditional anion exchangers elute only mRNA smaller than about 500 bases unless the columns are heated to 50–70°C. Hydrophobic interaction chromatography (HIC) and reverse phase chromatography (RPC) separate ssRNA from dsRNA and short transcripts, but their sensitivity to fouling by proteins and aggregates makes them better suited for polishing than for capture. Better capture options are needed to meet the needs of large clinical trials, scale-up, and manufacture of vaccines. Beyond that, a new spectrum of gene therapy treatments await. This article introduces two new capture options that both eliminate dsRNA, DNA, and proteins in a wash step, then provide high-resolution polishing of ssRNA in an elution gradient at ambient temperature. One represents a new class of anion exchangers. The other exploits hydrogen bonding. Both support prolonged exposure to 1 M sodium hydroxide. Easy transition to either HIC or RPC provides high-resolution orthogonal polishing.

Download full article

Full view

M. Morani, T.Duc Mai, Z. Krupova, P. Defrenaix, E. Multia, M. Riekkola, M. Taverna

Analytica Chimica Acta 1128 (2020) 45-51

Abstract

This work reports on the development of the first capillary electrophoresis methodology for the elucidation of extracellular vesicles’ (EVs) electrokinetic distributions. The approach is based on capillary electrophoresis coupled with laser-induced fluorescent (LIF) detection for the identification and quantification of EVs after their isolation. Sensitive detection of these nanometric entities was possible thanks to an ‘inorganic-species-free’ background electrolyte. This electrolyte was made up of weakly charged molecules at very high concentrations to stabilize EVs, and an intra-membrane labelling approach was used to prevent EV morphology modification. The limit of detection for EVs achieved using the developed CE-LIF method method reached 8 × 10⁹ EVs/mL, whereas the calibration curve was acquired from 1.22 × 10¹⁰ to 1.20 × 10¹¹ EVs/mL. The CE-LIF approach was applied to provide the electrokinetic distributions of various EVs of animal and human origins, and visualize different EV subpopulations from our recently developed high-yield EV isolation method.

Purchase full article

Full view

Pete Gagnon, Katja Vrabec, Tjaša Lojpur, and Aleš Štrancar

BioProcess International, 18 (4) April 2020

Abstract

Exosomes are a subject of rapidly growing therapeutic interest in the biopharmaceutical industry for two principal reasons. The first reason is that they are the primary communicators of instructions from source cells to target cells. Exosome surface features define their destination. They recognize complementary features on target cells, dock with them, and deliver their programmed instructions in the form of microRNA. The second reason is that exosomes are immunologically silent. As normal human cell products, and by contrast with gene therapy vectors such as virus particles, exosomes bypass the issue of triggering an immune response that might interfere with therapy.

Source cells include stem cells, which is why exosomes are of particular interest in the field of regenerative medicine. Recent research documenting the ability of exosomes to reverse the effects of severe strokes highlights their potential. It also underlines the need for scalable purification technology to advance these products through clinical trials and on to licensed manufacture. A platform approach was a major factor in the initial and continuing success of monoclonal antibodies. Exosomes likewise represent an extended family of individual products with similar properties. It stands to reason that a platform approach will prove equally valuable for exosomes. In this article we describe initial efforts toward that goal.

Contact us and request full article

Full view

Hietala V, Horsma-Heikkinen J, Carron A, Skurnik M, Kiljunen S.

Frontiers in microbiology vol. 10 1674. 23 Jul. 2019

Abstract

The production of phages for therapeutic purposes demands fast, efficient and scalable purification procedures. Phage lysates have a wide range of impurities, of which endotoxins of gram-negative bacteria and protein toxins produced by many pathogenic bacterial species are harmful to humans. The highest allowed endotoxin concentration for parenterally applied medicines is 5 EU/kg/h. The aim of this study was to evaluate the feasibility of different purification methods in endotoxin and protein toxin removal in the production of phage preparations for clinical use. In the purification assays, we utilized three phages: Escherichia phage vB_EcoM_fHoEco02, Acinetobacter phage vB_ApiM_fHyAci03, and Staphylococcus phage vB_SauM_fRuSau02. The purification methods tested in the study were precipitation with polyethylene glycol, ultracentrifugation, ultrafiltration, anion exchange chromatography, octanol extraction, two different endotoxin removal columns, and different combinations thereof. The efficiency of the applied purification protocols was evaluated by measuring phage titer and either endotoxins or staphylococcal enterotoxins A and C (SEA and SEC, respectively) from samples taken from different purification steps. The most efficient procedure in endotoxin removal was the combination of ultrafiltration and EndoTrap HD affinity column, which was able to reduce the endotoxin-to-phage ratio of vB_EcoM_fHoEco02 lysate from 3.5 × 104 Endotoxin Units (EU)/109 plaque forming units (PFU) to 0.09 EU/109 PFU. The combination of ultrafiltration and anion exchange chromatography resulted in ratio 96 EU/109 PFU, and the addition of octanol extraction step into this procedure still reduced this ratio threefold. The other methods tested either resulted to less efficient endotoxin removal or required the use of harmful chemicals that should be avoided when producing phage preparations for medical use. Ultrafiltration with 100,000 MWCO efficiently removed enterotoxins from vB_SauM_fRuSau02 lysate (from 1.3 to 0.06 ng SEA/109 PFU), and anion exchange chromatography reduced the enterotoxin concentration below 0.25 ng/ml, the detection limit of the assay.

Keywords: antibiotic resistance, bacteriophage, phage therapy, endotoxin, enterotoxin

Read full article

Full view

2019

Evgen Multia, Crystal Jing Ying Tear, Mari Palviainen, Pia Siljander, Marja-Liisa Riekkola

Analytica Chimica Acta (2019).
Published online 2019 Sep 11.

A new, fast and selective immunoaffinity chromatographic method including a methacrylate-based convective interaction media (CIM®) disk monolithic column, immobilized with anti-human CD61 antibody, was developed for the isolation of CD61-containing platelet-derived extracellular vesicles (EVs) from plasma. The isolated EVs were detected and size characterized by asymmetrical flow field-flow fractionation (AsFlFFF) with multi-angle light-scattering (MALS) and dynamic light-scattering (DLS) detection, and further confirmed by nanoparticle tracking analysis (NTA) and transmission electron microscopy (TEM). The isolation procedure took only 19 min and the time can be even further decreased by increasing the flow rate. The same immunoaffinity chromatographic procedure, following AsFlFFF allowed also the isolation and characterization of platelet-derived EVs from plasma in under 60 min. Since it is possible to regenerate the anti-CD61 disk for multiple uses, the methodology developed in this study provides a viable substitution and addition to the conventional EV isolation procedures.

Keywords: Immunoaffinity chromatography, Isolation, Monolithic disk column, Extracellular vesicles, Platelet-derived vesicles, CD61

Read full article

Full view

This discussion introduces new analytical approaches that enable in-line chromatographic detection of exosomes. One approach can discriminate extracellular vesicles from nonvesicle contaminants, and one potentially can discriminate exosomes from other vesicles. Examples illustrate how they enable development of more effective and better documented purification methods. The special qualifications of monolithic chromatography media for exosome purification are discussed. New process tools designed to accommodate some of the special challenges of exosome purification are introduced.

Feel free to download the eBook by clicking on the link to attachment below.

Attachments

Full view

2015

J-P Pirnay et al.

Pharm Res, Springer, 14 Jan 2015

The worldwide antibiotic crisis has led to a renewed interest in phage therapy. Since time immemorial phages control bacterial populations on Earth. Potent lytic phages against bacterial pathogens can be isolated from the environment or selected from a collection in a matter of days. In addition, phages have the capacity to rapidly overcome bacterial resistances, which will inevitably emerge.
To maximally exploit these advantage phages have over conventional drugs such as antibiotics, it is important that sustainable phage products are not submitted to the conventional long medicinal product development and licensing pathway. There is a need for an adapted framework, including realistic production and quality and safety requirements, that allows a timely supplying of phage therapy products for 'personalized therapy' or for public health or medical emergencies.
This paper enumerates all phage therapy product related quality and safety risks known to the authors, as well as the tests that can be performed to minimize these risks, only to the extent needed to protect the patients and to allow and advance responsible phage therapy and research.

Download full article

Full view

2013

E. A. Ponomareva, M. V. Volokitina, D. O. Vinokhodov, E. G. Vlakh, T. B. Tennikova

Anal Bioanal Chem (2013) 405:2195–2206

Immobilized enzyme reactors (IMERs) produced by the covalent attachment of ribonuclease A to macroporous
methacrylate-based monolithic supports using different experimental approaches are discussed and compared. Enzyme immobilization was carried out by direct covalent binding, as well as through attachment via a polymer spacer. The kinetic properties of an IMER operating in either recirculation mode or zonal elution mode were studied. Additionally, the effect of flow rate on the bioconversion efficiency of each IMER sample was examined.

Purchase full article

Full view

M. V. Volokitina, E. G. Vlakh, G. A. Platonova, D. O. Vinokhodov, T. B. Tennikova
J. Sep. Sci. 2013, 36, 2793-2805

Two ribonuclease A bioreactors based on lab-made macroporous monolithic columns and intended for polynucleotide degradation were prepared using in situ free-radical polymerization. Different methods of enzyme immobilization were applied. In the first case, the biocatalyst molecule was attached to the solid surface via direct covalent binding, while in the second bioreactor the flexible-chain synthetic polymer was used as an intermediate spacer. The effect of temperature, substrate flow rate, and loaded sample volume on the biocatalytic efficiency of the immobilized enzyme was examined. The kinetic parameters of the enzymatic degradation of synthetic polycytidylic acid were calculated and compared to those found for hydrolysis with soluble ribonuclease A. The monitoring of substrate splitting was carried out by means of fast anion-exchange HPLC on an ultra-short monolithic column (disk) using off- and on-line analytical approaches.

Purchase full article

Full view

2012

E. S. Sinitsyna, J. G. Walter, E. G. Vlakh, F. Stahl, C. Kasper, T. B. Tennikova
Talanta 93 (2012) 139-146

Macroporous monoliths with different surface functionalization (reactive groups) were utilized as platforms for DNA analysis in microarray format. The slides based on a copolymer glycidyl methacrylate-co- ethylene dimethacrylate (GMA-EDMA) have been chosen as well known and thoroughly studied standard. In particular, this material has been used at optimization of DNA microanalytical procedure.

The concentration and pH of spotting solution, immobilization temperature and time, blocking agent and coupling reaction duration were selected as varied parameters. The efficiency of analysis performed on 3-D monolithic platforms was compared to that established for commercially available glass slides. As a practical example, a diagnostic test for detection of CFTR gene mutation was carried out. Additionally, the part of presented work was devoted to preparation of aptamer-based test-system that allowed successful and highly sensitive detection both of DNA and protein.

Purchase full article

Full view

2010

F. Mancini, V. Andrisano

Journal of Pharmaceutical and Biomedical Analysis 52 (2010) 355-361

A novel liquid chromatographic method has been developed for use in throughput screening of new inhibitors of human recombinant β-amyloid precursor protein cleaving enzyme (hrBACE1). The approach is based on the use of an immobilized enzyme reactor (IMER) containing the target enzyme (hrBACE1–IMER) and uses fluorescence detection. The bioreactor was prepared by immobilizing hrBACE1 on an ethylendiamine (EDA) monolithic disk (CIM) and a fluorogenic peptide (M-2420) containing the β-secretase site of the Swedish mutation of amyloid precursor protein (APP) was used as substrate. After injection into the hrBACE1–IMER system, M-2420 was enzymatically cleaved, giving rise to a fluorescent methoxycoumaryl-fragment (Rt = 1.6 min), which was separated from the substrate and selectively detected at λexc = 320 and λem = 420 nm. Product and substrate were characterized by using a post monolithic C18 stationary phase coupled to an ion trap mass analyser. A calibration curve was constructed to determine the immobilized hrBACE1–IMER rate of catalysis and kinetic constants. Specificity of the enzymatic cleavage was confirmed by injecting the substrate on a blank CIM-EDA.

The proposed method was validated by the determination of the inhibitory potency of five reference compounds with activities ranked over four order of magnitude (four peptidic inhibitors and a green tea polyphenol, (−)gallocatechin gallate). The obtained results were found in agreement with the data reported in literature, confirming the validity and the applicability of the hrBACE1–IMER as a tool for the fast screening of unknown inhibitors (more than 6 compounds per hour). Moreover, the hrBACE1–IMER showed high stability during the analysis, permitting its use for more than three months without affecting enzyme activity.

Purchase full article

Full view

2007

M. Benčina, J. Babič, A. Podgornik

Journal of Chromatography A, 1144 (2007) 135–142

In gene therapy and DNA vaccination, RNA removal from DNA preparations is vital and is typically achieved by the addition of ribonuclease into the sample. Removal of ribonuclease from DNA samples requires an additional purification step. An alternative is the implementation of immobilized ribonuclease. In our work, ribonuclease was covalently coupled onto the surface of methacrylate monoliths via epoxy or imidazole carbamate groups. Various immobilization conditions were tested by changing immobilization pH. Ribonuclease immobilized on the monolith via imidazole carbamate groups at pH 9 was found to be six times more active than the ribonuclease immobilized on the monolith via epoxy groups. Under optimal immobilization conditions the Michaelis–Menten constant, Km, for cytidine-2,3-cyclic monophosphate, and turnover number, k3 were 0.52 mM and 4.6 s-1, respectively, and mirrored properties of free enzyme. Enzyme reactor was found to efficiently eliminate RNA contaminants from DNA samples. It was active for several weeks of operation and processed 300 column volumes of sample. Required residence time to eliminate RNA was estimated to be around 0.5 min enabling flow rates above 1 column volume per min.

Purchase full article

Full view

2005

G. A. Platonova, T. B. Tennikova

Journal of Chromatography A, 1065 (2005) 75–81(2005) 75–81

High-performance monolithic disk affinity chromatography was applied to the investigation of formation of complexes between (1) complementary polyriboadenylic and polyribouridylic acids, e.g. poly(A) and poly(U), respectively, (2) poly(A) and synthetic polycation poly(allylamine), pAA. Polyriboadenylic acid and poly(allylamine) were immobilized on macroporous disks (CIM disks). Quantitative parameters of affinity interactions between macromolecules were established using frontal analysis at different flow rates.

Purchase full article

Full view

M. Benčina, K. Benčina, A. Štrancar, A. Podgornik

Journal of Chromatography A, 1065 (2005) 83–91(2005) 83–91

A deoxyribonuclease bioreactor was prepared by immobilization of deoxyribonuclease I through epoxy groups inherently present on poly (glycidyl methacrylate-co-ethylene dimethacrylate) monoliths. Columns with various levels of DNase activity were prepared varying immobilization temperature, pH, time and method. The apparent Michaelis–Menten constant, Kmapp, and turnover number, k3app, for immobilized DNase determined by on-line frontal analysis method were, respectively, 0.28 g of DNA l-1 and 16 dA260nm min-1 mg-1 of immobilized DNase. The highest activity of immobilized DNase was detected at 1 mM calcium ions concentration and mirrored properties of free enzyme; however, reaction temperature in the range from 25 to 37 °C has no significant effect on activity of immobilized DNase in contrary to free enzyme. The CIM DNase bioreactor was used for elimination of DNA contaminants in RNA samples prior to reverse transcription followed by PCR.

Purchase full article

Call

Send SMS

Add to Skype

You'll need Skype CreditFree via Skype

Full view