On May 12th, the biaseparations.com website will be retired and migrated tosartorius.com.Learn moreabout our combined offering today!
2020

U. Černigoj, A. Štrancar

DNA Vaccines. Methods in Molecular Biology, vol 2197, pp 167-192

Abstract

Purification of high-quality plasmid DNA in large quantities is a crucial step in its production for therapeutic use and is usually conducted by different chromatographic techniques. Large-scale preparations require the optimization of yield and homogeneity, while maximizing removal of contaminants and preserving molecular integrity. The advantages of Convective Interaction Media® (CIM®) monolith stationary phases, including low backpressure, fast separation of macromolecules, and flow-rate-independent resolution qualified them to be used effectively in separation of plasmid DNA on laboratory as well as on large scale. A development and scale-up of plasmid DNA downstream process based on chromatographic monoliths is described and discussed below. Special emphasis is put on the introduction of process analytical technology principles and tools for optimization and control of a downstream process.

Buy protocol

Full view

P. Gagnon, B. Goričar, Š. Peršič, U. Černigoj, A. Štrancar

Cell & Gene Therapy Insights 2020; 6(7), 1035–1046

Abstract:

One of the barriers to development of industrial purification platforms for large mRNA has been an inadequate selection of high-performing capture-purification tools. Hybridization-affinity uses a polythymidine (Oligo dT) ligand to base-pair with the polyadenine tail of mRNA. It can be used for capture but it cannot discriminate dsRNA (double-stranded) from ssRNA (single-stranded) and it supports only brief cleaning with 100 mM sodium hydroxide. Traditional anion exchangers elute only mRNA smaller than about 500 bases unless the columns are heated to 50–70°C. Hydrophobic interaction chromatography (HIC) and reverse phase chromatography (RPC) separate ssRNA from dsRNA and short transcripts, but their sensitivity to fouling by proteins and aggregates makes them better suited for polishing than for capture. Better capture options are needed to meet the needs of large clinical trials, scale-up, and manufacture of vaccines. Beyond that, a new spectrum of gene therapy treatments await. This article introduces two new capture options that both eliminate dsRNA, DNA, and proteins in a wash step, then provide high-resolution polishing of ssRNA in an elution gradient at ambient temperature. One represents a new class of anion exchangers. The other exploits hydrogen bonding. Both support prolonged exposure to 1 M sodium hydroxide. Easy transition to either HIC or RPC provides high-resolution orthogonal polishing.

Download full article

Full view

M. Morani, T.Duc Mai, Z. Krupova, P. Defrenaix, E. Multia, M. Riekkola, M. Taverna

Analytica Chimica Acta 1128 (2020) 45-51

Abstract

This work reports on the development of the first capillary electrophoresis methodology for the elucidation of extracellular vesicles’ (EVs) electrokinetic distributions. The approach is based on capillary electrophoresis coupled with laser-induced fluorescent (LIF) detection for the identification and quantification of EVs after their isolation. Sensitive detection of these nanometric entities was possible thanks to an ‘inorganic-species-free’ background electrolyte. This electrolyte was made up of weakly charged molecules at very high concentrations to stabilize EVs, and an intra-membrane labelling approach was used to prevent EV morphology modification. The limit of detection for EVs achieved using the developed CE-LIF method method reached 8 × 10⁹ EVs/mL, whereas the calibration curve was acquired from 1.22 × 10¹⁰ to 1.20 × 10¹¹ EVs/mL. The CE-LIF approach was applied to provide the electrokinetic distributions of various EVs of animal and human origins, and visualize different EV subpopulations from our recently developed high-yield EV isolation method.

Purchase full article

Full view

Pete Gagnon, Katja Vrabec, Tjaša Lojpur, and Aleš Štrancar

BioProcess International, 18 (4) April 2020

Abstract

Exosomes are a subject of rapidly growing therapeutic interest in the biopharmaceutical industry for two principal reasons. The first reason is that they are the primary communicators of instructions from source cells to target cells. Exosome surface features define their destination. They recognize complementary features on target cells, dock with them, and deliver their programmed instructions in the form of microRNA. The second reason is that exosomes are immunologically silent. As normal human cell products, and by contrast with gene therapy vectors such as virus particles, exosomes bypass the issue of triggering an immune response that might interfere with therapy.

Source cells include stem cells, which is why exosomes are of particular interest in the field of regenerative medicine. Recent research documenting the ability of exosomes to reverse the effects of severe strokes highlights their potential. It also underlines the need for scalable purification technology to advance these products through clinical trials and on to licensed manufacture. A platform approach was a major factor in the initial and continuing success of monoclonal antibodies. Exosomes likewise represent an extended family of individual products with similar properties. It stands to reason that a platform approach will prove equally valuable for exosomes. In this article we describe initial efforts toward that goal.

Contact us and request full article

Full view

2019

Wang Chunlei, Mulagapati Sri Hari Raju, Chen Zhongying, Du Jing, Zhao Xiaohui, Xi Guoling, Chen Liyan, Linke Thomas, Gao Cuihua, Schmelzer Albert, Liu Dengfeng

Molecular Therapy  Methods & Clinical Development, Volume 15, September 26 2019, Pages 257-263

Abstract

Adeno-associated virus (AAV) vectors are clinically proven gene delivery vehicles that are attracting an increasing amount of attention. Non-genome-containing empty AAV capsids are by-products during AAV production that have been reported to potentially impact AAV product safety and efficacy. Therefore, the presence and amount of empty AAV capsids need to be characterized during process development. Multiple methods have been reported to characterize empty AAV capsid levels, including transmission electron microscopy (TEM), analytical ultracentrifugation (AUC), charge detection mass spectrometry (CDMS), UV spectrophotometry, and measuring capsid and genome copies by ELISA and qPCR. However, these methods may lack adequate accuracy and precision or be challenging to transfer to a quality control (QC) lab due to the difficulty of implementation. In this study, we used AAV serotype 6.2 (AAV6.2) as an example to show the development of a QC-friendly anion exchange chromatography (AEX) assay for the determination of empty and full capsid percentages. The reported assay requires several microliters of material with a minimum titer of 5 × 1011 vg/mL, and it can detect the presence of as low as 2.9% empty capsids in AAV6.2 samples. Additionally, the method is easy to deploy, can be automated, and has been successfully implemented to support testing of various in-process and release samples.

Read full article

Keywords: AAV, AAV6.2, Chromatography, Anion exchange chromatography (AEC), Empty capsids, AUC, High-throughput

Full view

Sofiya Fedosyuk, Thomas Merritt, Marco Polo Peralta-Alvarez, Susan J. Morris, Ada Lam, Nicolas Laroudie, Anilkumar Kangokar, Daniel Wright, George M. Warimwe, Phillip Angell-Manning, Adam J. Ritchie, Sarah C. Gilbert, Alex Xenopoulos, Anissa Boumlic, Alexander D. Douglas

Vaccine (2019).
Published online 30 April 2019.

A variety of Good Manufacturing Practice (GMP) compliant processes have been reported for production of non-replicating  adenovirus vectors, but important challenges remain. There is a need for rapid production platforms for small GMP batches of non-replicating adenovirus vectors for early-phase vaccine trials, particularly in preparation for response to emerging pathogen outbreaks. Such platforms must be robust to variation in the transgene, and ideally also capable of producing adenoviruses of more than one serotype. It is also highly desirable for such processes to be readily implemented in new facilities using  commercially available single-use materials, avoiding the need for development of bespoke tools or cleaning validation, and for them to be readily scalable for later-stage studies.
Here we report the development of such a process, using single-use stirred-tank bioreactors, a transgene-repressing HEK293 cell – promoter combination, and fully single-use filtration and ion exchange components. We demonstrate applicability of the process to candidate vaccines against rabies, malaria and Rift Valley fever, each based on a different adenovirus serotype.

Keywords: Simian adenovirus, GMP, Clinical trials, Single-use, Biomanufacturing, Bioreactor, Purification

Read full article

Full view

Evgen Multia, Crystal Jing Ying Tear, Mari Palviainen, Pia Siljander, Marja-Liisa Riekkola

Analytica Chimica Acta (2019).
Published online 2019 Sep 11.

A new, fast and selective immunoaffinity chromatographic method including a methacrylate-based convective interaction media (CIM®) disk monolithic column, immobilized with anti-human CD61 antibody, was developed for the isolation of CD61-containing platelet-derived extracellular vesicles (EVs) from plasma. The isolated EVs were detected and size characterized by asymmetrical flow field-flow fractionation (AsFlFFF) with multi-angle light-scattering (MALS) and dynamic light-scattering (DLS) detection, and further confirmed by nanoparticle tracking analysis (NTA) and transmission electron microscopy (TEM). The isolation procedure took only 19 min and the time can be even further decreased by increasing the flow rate. The same immunoaffinity chromatographic procedure, following AsFlFFF allowed also the isolation and characterization of platelet-derived EVs from plasma in under 60 min. Since it is possible to regenerate the anti-CD61 disk for multiple uses, the methodology developed in this study provides a viable substitution and addition to the conventional EV isolation procedures.

Keywords: Immunoaffinity chromatography, Isolation, Monolithic disk column, Extracellular vesicles, Platelet-derived vesicles, CD61

Read full article

Full view

Dr. Xiaotong Fu, Dr. Wei-Chiang  Chen, C. Argento, R. Dickerson, P. Clarner, V. Bhatt, G. Bou-Assaf, Dr. M. Bakhshayeshi, Dr. Xiaohui Lu, Dr. S. Bergelson, Dr. J. Pieracci

Human Gene Therapy (2019)

Recombinant adeno-associated virus (rAAV)-mediated gene therapy is a fast-evolving field in the biotechnology industry. One of the major challenges in developing a purification process for AAV gene therapy is establishing an effective yet scalable method to remove empty capsids, or viral vectors lacking the therapeutic gene, from full capsids—viral product containing the therapeutic sequence. Several analytical methods that can quantify the empty-to-full capsid ratio have been reported in the literature. However, as samples can vary widely in viral titer, buffer matrix, and the relative level of empty capsids, understanding the specifications and limitations of different analytical methods is critical to providing appropriate support to facilitate process development. In this study, we developed a novel anion-exchange high-performance liquid chromatography (AEX-HPLC) assay to determine the empty-to-full capsid ratio of rAAV samples. The newly developed method demonstrated good comparability to both the transmission electron microscopy (TEM) and analytical ultracentrifugation (AUC) methods used in empty-to-full capsid ratio quantification, yet providing much higher assay throughput and reducing the minimum sample concentration requirement to 2.7E11 viral genomes (vg)/ml.

Purchase full article

Full view

K. Trabelsi, M. Ben Zakour, H. Kallel

Vaccine (2019)

Rabies is a viral zoonosis caused by negative-stranded RNA viruses of the Lyssavirus genus. It can affect all mammals including humans. Dogs are the main source of human rabies deaths, contributing up to 99% of all rabies transmissions to humans. Vaccination against rabies is still the sole efficient way to fight against the disease.
Cell culture vaccines are recommended by World Health Organization (WHO) for pre and post exposure prophylaxis; among them Vero cell rabies vaccines which are used worldwide. In this work we studied the purification of inactivated rabies virus produced in Vero cells grown in animal component free conditions, using different methods. Cells were grown in VP-SFM medium in stirred bioreactor, then infected at an MOI of 0.05 with the LP2061 rabies virus strain. Collected harvests were purified by zonal centrifugation, and by chromatography supports, namely the Capto Core 700 and the monolithic CIM-QA column. Generated data were compared in terms of residual DNA level, host cell proteins (HCP) level and the overall recovery yield.
 

Purchase full article

Full view

This discussion introduces new analytical approaches that enable in-line chromatographic detection of exosomes. One approach can discriminate extracellular vesicles from nonvesicle contaminants, and one potentially can discriminate exosomes from other vesicles. Examples illustrate how they enable development of more effective and better documented purification methods. The special qualifications of monolithic chromatography media for exosome purification are discussed. New process tools designed to accommodate some of the special challenges of exosome purification are introduced.

Feel free to download the eBook by clicking on the link to attachment below.

Attachments

Full view

2018

M. Tajnik Sbaizero, M. Wolschek, M. Reiter, T. Muster, Pete Gagnon and Aleš Štrancar

BioProcess International, 15 October 2018

Influenza is a global respiratory disease with an estimated mortality of up to a half million people per year. The majority of traditional influenza vaccines are still produced in eggs. Downstream processing typically consists of clarification by centrifugation, concentration by ultrafiltration, and purification by ultracentrifugation. Recombinant vaccines are most often purified by chromatography. Chromatographic purification of viruses already has achieved major improvements in recovery and scalability, but it also is important because it enables virus purification to keep pace with important regulatory and manufacturing trends across the field of biopharmaceuticals. One of those trends is process intensification, referring to development of processes that harmonize integration of fewer and more capable steps to achieve higher productivity and reproducibility as well as reduce manufacturing costs.
In this report we describe processes for purification of influenza A and influenza B, both lacking TFF steps, and both using a single chromatography step with a cation exchange monolith on a single-use basis. The choice of process buffers enables final formulation by simple dilution of the product pool. DNA digestion requires two hours. Capture, purification, and formulation are achieved within four hours. Host-cell DNA and host-cell protein (HCP) are reduced more than 99%, and final virus recovery is 80%.

Download full article

Full view

Laura M. Fischer, Michael W. Wolff, Udo Reichl, Vaccine 2017 July 17

The continuously increasing demand for potent and safe vaccines and the intensifying economic pressure on health care systems underlines the need for further optimization of vaccine manufacturing. Here, we focus on downstream processing of human influenza vaccines, investigating the purification of serum free cell culture-derived influenza virus (A/PR/8/34 H1N1) using continuous chromatography. Therefore, quaternary amine anion exchange monoliths (CIM QA) were characterized for their capacity to capture virus particles from animal cells cultivated in different media and their ability to separate virions from contaminating host cell proteins and DNA. The continuous chromatography was implemented as simulated moving bed chromatography (SMB) in a three zone open loop configuration with a detached high salt zone for regeneration.
SMBs exploiting 10% and 50% of the monoliths’ dynamic binding capacity, respectively, allowed the depletion of >98% of the DNA and >52% of the total protein. Based on the hemagglutination assay (HA assay), the virus yield was higher at 10% capacity use (89% vs. 45%). Both SMB  separations resulted in a ratio of total protein to hemagglutinin antigen (based on single radial diffusion assay, SRID assay) below the required levels for manufacturing of human vaccines (less than 100 mg of protein per virus strain per dose). The level of contaminating DNA was five-times lower for the 10% loading, but still exceeded the required limit for human vaccines. A subsequent Benzonase treatment step, however, reduced the DNA contamination below 10 ng per dose. Coupled to continuous cultivations for virus propagation, the establishment of integrated processes for fully continuous production of vaccines seems to be feasible.

Download full article

Full view

Miladys Limonta, Lourdes Zumalacarregui, Urska Vidic, Nika Lendero Krajnc

The main component of the Center for Genetic Engineering and Biotechnology (CIGB) candidate vaccine against Hepatitis C virus (HCV) is the pIDKE2 plasmid. The current designed downstream process for the production of pIDKE2 fulfils all regulatory requirements and renders the required quantities of pharamceutical-grade plasmid DNA (pDNA)with 95% purity. The advantages of this procedure include high plasmid purity and the elimination of undesirable additives. such as toxic organic extractants and animal-derived enzymes. However, yields and consequently the productivity of the process are low. Previous work demonstrated that the most critical step of the process is the reverse phase chromatography, where conventional porous particle resins are used. Therefore, to increase the process productivity alternative technologies such as membranes and chromatographic monoliths were tested as alternative options for this critical step. Here, a comparison between the behaviours of CIM® C4-HLD and Sartobind phenyl matrices was performed.

Attachments

Full view

2017

Alicia T Lucero, Sergio A Mercado, Anamaría C Sánchez,Carolina A Contador, Barbara A Andrews and Juan A Asenjo, Journal of chemical technology and biotechnology, (2017)

BACKGROUND: Gene therapy is a potent alternative for long-lasting inhibition of alcohol consumption. This study compares the purification of a recombinant adenoviral vector serotype 5 (rAdV5) for use in gene therapy against alcoholism using two anion-exchange methods.

RESULTS: Two anion-exchange chromatography methods using fast protein liquid chromatography were compared using a packed-bed column (Q-Sepharose™ XL) and two monolithic columns (CIM™ QA-1 and CIM™ DEAE-1). An improved and reproducible separation of recombinant adenovirus type 5 from cell lysate contaminants was achieved using the two strong anion-exchange columns in a two-step gradient chromatography. Higher adenovirus yields were achieved using the CIM QA-1 tube monolithic column at sample volumes of both 1 and 10 mL compared with the Q-Sepharose XL column. At higher flow rates, the CIM QA-1 tube monolithic column achieved better separation of the target fraction. Process recovery was improved from 28% using the Q-Sepharose XL column to 34% with the CIM QA-1 tube monolithic column quantified as vector genome. Analysis by SDS-PAGE demonstrated a purity of 70% for purified adenovirus using the CIM QA-1 tube monolithic column.

CONCLUSION: This study indicated that the use of a CIM QA-1 tube monolithic column is a better alternative than Q-Sepharose XL, and CIM DEAE-1 tube monolithic columns for the primary purification process of rAdV5 carrying the human aldehyde dehydrogenase-2 antisense gene. This purification strategy has been used as a basis to scale-up a GLP process for the production of material at the National Research Council of Canada to be used in preclinical trials of this gene therapy against alcoholism

Download full article

Full view

David Vincent, Petra Kramberger, Rosana Hudej, Aleš Štrancar, Yaohe Wang,Yuhong Zhou, Ajoy Velayudhan

The purification of large viruses remains an important field of research and development. The development of efficient purification trains is limited by limited analytical methods, as well as by the complexity of large viruses, as well as the high variability in starting material from cell culture. Vaccinia virus holds great potential as an oncolytic and immunotherapeutic vaccine against a broad spectrum of cancers. In this work, monolith-based capture and polishing chromatographic steps for vaccinia virus Lister strain has been developed. Virus produced in CV-1 cells was harvested and passed through a 0.8μm pre-filter before loading onto CIEX, AIEX and HIC CIM monoliths. Without the need for nuclease treatment, up to 99% of the total DNA loaded can be removed from the vaccinia feed stream by the CIM OH monolith, which also reduces the total protein concentration in the product pool to LLOQ levels, and achieves infectious virus recoveries of 90%. Binding capacities of greater than 1x109 pfu of vaccinia per mL of matrix were obtained on both CIM SO3 and CIM OH monoliths. Multiple orthogonal analytical methods have been used to develop process knowledge and understanding.

Attachments

Full view

2016

P. Stepperta, D. Burgstallera, M. Klausbergera, E. Bergerb, P.P. Aguilara, T.A. Schneiderb, P. Krambergerc, A. Toverd,  K. Nöbauere, E. Razzazi-Fazelie, A. Jungbauer, Journal of Chromatography A, 1455 (2016)

Enveloped virus-like particles (VLPs) are increasingly used as vaccines and immunotherapeutics. Frequently, very time consuming density gradient centrifugation techniques are used for purification ofVLPs. However, the progress towards optimized large-scale VLP production increased the demand for fast, cost efficient and scaleable purification processes. We developed a chromatographic procedure for purification of HIV-1 gag VLPs produced in CHOcells. The clarified and filtered cell culture supernatant was directly processed on an anion-exchange monolith. The majority of host cell impurities passed throughthe column, whereas the VLPs were eluted by a linear or step salt gradient; the major fraction of DNA waseluted prior to VLPs and particles in the range of 100–200nm in diameter could be separated into two fractions. The earlier eluted fraction was enriched with extracellular particles associated to exosomes or microvesicles, whereas the late eluting fractions contained the majority of most pure HIV-1 gag VLPs. DNA content in the exosome-containing fraction could not be reduced by Benzonase treatment which indicated that the DNA was encapsulated. Many exosome markers were identified by proteomic analysisin this fraction. We present a laboratory method that could serve as a basis for rapid downstream processing of enveloped VLPs. Up to 2000 doses, each containing 1×109 particles, could be processed witha 1mL monolith within 47 min. The method compared to density gradient centrifugation has a 220-fold improvement in productivity.

Download full article

Full view

2015

J. Transfiguracion, A. P. Manceur, E. Petiot, C. M. Thompson, A. A. Kamen
Vaccine (2014)

The influenza virus continuously undergoes antigenic evolution requiring manufacturing, validation and release of new seasonal vaccine lots to match new circulating strains. Although current production processes are well established for manufacturing seasonal inactivated influenza vaccines, significant limitations have been underlined in the case of pandemic outbreaks. The World Health Organization called for a global pandemic influenza vaccine action plan including the development of new technologies. A rapid and reliable method for the quantification of influenza total particles is crucially needed to support the development, improvement and validation of novel influenza vaccine manufacturing platforms. This work presents the development of an ion exchange-high performance liquid chromatography method for the quantification of influenza virus particles. The method was developed using sucrose cushion purified influenza viruses A and B produced in HEK 293 suspension cell cultures. The virus was eluted in 1.5 M NaCl salt with 20 mM Tris–HCl and 0.01% Zwittergent at pH 8.0. It was detected by native fluorescence and the total analysis time was 13.5 min. A linear response range was established between 1 × 109 and 1 × 1011 virus particle per ml (VP/ml) with a correlation coefficient greater than 0.99. The limit of detection was between 2.07 × 108 and 4.35 × 109 whereas the limit of quantification was between 6.90 × 108 and 1.45 × 1010 VP/ml, respectively. The coefficient of variation of the intra- and inter-day precision of the method was less than 5% and 10%. HPLC data compared well with results obtained by electron microscopy, HA assay and with a virus counter, and was used to monitor virus concentrations in the supernatant obtained directly from the cell culture production vessels. The HPLC influenza virus analytical method can potentially be suitable as an in-process monitoring tool to accelerate the development of processes for the manufacturing of influenza vaccines.

Purchase full article

Full view

A.M. Almeida, J.A. Queiroz, F. Sousa, A. Sousa

Journal of Chromatography B, 978–979 (2015) 145–150

The progress of DNA vaccines is dependent on the development of suitable chromatographic procedures to successfully purify genetic vectors, such as plasmid DNA. Human Papillomavirus is associated with the development of tumours due to the oncogenic power of E6 and E7 proteins, produced by this virus. The supercoiled HPV-16 E6/E7 plasmid-based vaccine was recently purified with the arginine monolith, with 100% of purity, but only 39% of recovery was achieved. Therefore, the present study describes the application of experimental design tools, a newly explored methodology in preparative chromatography, in order to improve the supercoiled plasmid DNA recovery with the arginine monolith, maintaining the high purity degree. In addition, the importance and influence of pH in the pDNA retention to the arginine ligand was also demonstrated. The Composite Central Face design was validated and the recovery of the target molecule was successfully improved from 39% to 83.5%, with an outstanding increase of more than double, while maintaining 100% of purity.

Purchase full article

Full view

J. Ruscic, I. Gutiérrez-Aguirre, M. Tusek Znidaric, S. Kolundzija, A. Slana, M. Barut, M. Ravnikar, M. Krajacic
Journal of Chromatography A, 1388 (2015) 69–78

The emergence of next-generation "deep" sequencing has enabled the study of virus populations with much higher resolutions. This new tool increases the possibility of observing mixed infections caused by combinations of plant viruses, which are likely to occur more frequently than previously thought. The bio-logical impact of co-infecting viruses on their host has yet to be determined and fully understood, and the first step towards reaching this goal is the separation and purification of individual species. Ion-exchange monolith chromatography has been used successfully for the purification and concentration of different viruses, and number of them have been separated from plant homogenate or bacterial and eukaryoticlysate. Thus, the question remained as to whether different virus species present in a single sample could be separated. In this study, anion-exchange chromatography using monolithic supports was optimized for fast and efficient partial purification of three model plant viruses: Turnip yellow mosaic virus, Tomato bushy stunt virus, and Tobacco mosaic virus. The virus species, as well as two virus strains, were separated from each other in a single chromatographic experiment from an artificially mixed sample. Based on A260/280 ratios, we were able to attribute specific peaks to a certain viral morphology/structure (icosa-hedral or rod-shaped). This first separation of individual viruses from an artificially prepared laboratory mixture should encourage new applications of monolithic chromatographic supports in the separation of plant, bacterial, or animal viruses from all kinds of mixed samples.

Download full article

Full view

Zunyang Ke, Yu Wang and Zhongming Li

Anion-exchange chromatography is a key capture step in downstream processing plasmid DNA (pDNA). Separation of pDNA using traditional particle-based anion-exchange supports is usually slow and has a low capacity for pDNA due to steric exclusion effects. Due to convective mass transfer properties, and large flow-through channels for binding large biomolecules, monoliths have been shown to provide a fast and efficient alternative for pDNA purification. This study describes the use of monoliths for purification of a therapeutic pDNA vaccine against multidrug resistant tuberculosis (MDR TB).

Attachments

Full view