2011

C. Burden, J. Jin, A. Podgornik, D. G. Bracewell

Journal of Chromatography B, 880 (2012) 82- 89

Monoliths are an alternative stationary phase format to conventional particle based media for large biomolecules. Conventional resins suffer from limited capacities and flow rates when used for viruses, virus-like particles (VLP) and other nanoplex materials. The monolith structure provides a more open pore structure to improve accessibility for these materials and better mass transport from convective flow and reduced pressure drops. To examine the performance of this format for bioprocessing we selected the challenging capture of a VLP from clarified yeast homogenate. Using a recombinant Saccharomyces cerevisiae host it was found hydrophobic interaction based separation using a hydroxyl derivatised monolith had the best performance. The monolith was then compared to a known beaded resin method, where the dynamic binding capacity was shown to be three-fold superior for the monolith with equivalent 90% recovery of the VLP. To understand the impact of the crude feed material confocal microscopy was used to visualise lipid contaminants, deriving from the homogenised yeast. It was seen that the lipid formed a layer on top of the column, even after regeneration of the column with isopropanol, resulting in increasing pressure drops with the number of operational cycles. Removal of the lipid pre-column significantly reduces the amount and rate of this fouling process. Using Amberlite/XAD-4 beads around 70% of the lipid was removed, with a loss of VLP around 20%. Applying a reduced lipid feed versus an untreated feed further increased the dynamic binding capacity of the monolith from 0.11 mg/mL column to 0.25 mg/mL column.

Read full article

Full view

L. Urbas, B. Lah Jarc, M. Barut, M. Zochowska, J. Chroboczek

Journal of Chromatography A, 1218 (2011) 2451-2459

Adenovirus type 3 dodecahedric virus-like particles (Ad3 VLP) are an interesting delivery vector. They penetrate animal cells in culture very efficiently and up to 300,000 Ad3 VLP can be observed in one cell. The purification of such particles usually consists of several steps. In these work we describe the method development and optimization for the purification of Ad3 VLP using the Convective Interaction Media analytical columns (CIMac). Results obtained with the CIMac were compared to the already established two-step purification protocol for Ad3 VLP based on sucrose density gradient ultracentifugation and the Q-Sepharose ion-exchange column. Pure, concentrated and bioactive VLP were obtained and characterized by several analytical methods. The recovery of the Ad3 VLP was more than 50% and the purified fraction was almost completely depleted of DNA; less than 1% of DNA was present. The purification protocol was shortened from five days to one day and remarkably high penetration efficacy of the CIMac-purified vector was retained. Additionally, CIMac QA analytical column has proven to be applicable for the final and in-process control of various Ad3 VLP samples.

Purchase full article

Full view

M. J. Shin, L. Tan, M. H. Jeong, J.-H. Kim, W.-S. Choe

Journal of Chromatography A, 1218 (2011) 5273-5278

Immobilized metal affinity monolith column as a new class of chromatographic support is shown to be superior to conventional particle-based column as plasmid DNA (pDNA) purification platform. By harnessing the affinity of endotoxin to copper ions in the solution, a majority of endotoxin (90%) was removed from the alkaline cell lysate using CuCl2-induced precipitation. RNA and remaining endotoxin were subsequently removed to below detection limit with minimal loss of pDNA using either monolith or particle-based column. Monolith column has the additional advantage of feed concentration and flowrate-independent dynamic binding capacity for RNA molecules, enabling purification process to be conducted at high feed RNA concentration and flowrate. The use of monolith column gives three fold increased productivity of pDNA as compared to particle-based column, providing a more rapid and economical platform for pDNA purification.

Purchase full article

Full view

2010

F. Smrekar, A. Podgornik, M. Ciringer, S. Kontrec, P. Raspor, A. Štrancar, M. Peterka

Vaccine 28 (2010) 2039–2045

Plasmid DNA (pDNA) used in vaccination and gene therapy has to be highly pure and homogenous, which point out necessity to develop efficient, reproducible and scalable downstream process. Convective Interaction Media (CIM) monolithic chromatographic supports being designed for purification of large molecules and nanoparticles seem to be a matrix of choice for pDNA purification. In present work we describe a pDNA purification process designed on two different CIM monolithic columns, based on anion-exchange (AEX) chromatography and hydrophobic interaction chromatography (HIC) chemistry. HIC monolith enabled separation of supercoiled (sc) pDNA from open circular (oc) pDNA, genomic DNA (gDNA) and endotoxins regardless to flow rates in the range at least up to 380 cm/h. Dynamic binding capacity of new HIC monolith is up to 4 mg of pDNA per milliliter of support. Combination of both chromatographic steps using optimized CaCl2 precipitation enabled production of pure pDNA, satisfying all regulatory requirements. Process was found to be reproducible, scalable, and exhibits high productivity. In addition, in-line monitoring of pDNA purification process is shown, using CIM DEAE disk monolithic columns.

Purchase full article

Full view

N. Lendero Krajnc, F. Smrekar, A. Štrancar, A. Podgornik

Journal of Chromatography A, 1218 (2011) 2413-2424

The objective of this study was to investigate the behavior of large plasmids on the monolithic columns under binding and nonbinding conditions. The pressure drop measurements under nonbinding conditions demonstrated that the flow velocities under which plasmid passing monolith became hindered by the monolithic pore structure depended on the plasmid size as well as on the average monolith pore size; however, they were all very high exceeding the values encountered when applying CIM monolithic columns at their maximal flow rate. The impact of the ligand density and the salt concentration in loading buffer on binding capacity of the monolith for different sized plasmids was examined. For all plasmids the increase of dynamic binding capacity with the increase of salt concentration in the loading solution was observed reaching maximum of 7.1 mg/mL at 0.4 M NaCl for 21 kbp, 12.0 mg/mL at 0.4 M NaCl for 39.4 kbp and 8.4 mg/mL at 0.5 M NaCl for 62.1 kbp. Analysis of the pressure drop data measured on the monolithic column during plasmid loading revealed different patterns of plasmid binding to the surface, showing “car-parking problem” phenomena under certain conditions. In addition, layer thickness of adsorbed plasmid was estimated and at maximal dynamic binding capacity it matched calculated plasmid radius of gyration. Finally, it was found that the adsorbed plasmid layer acts similarly as the grafted layer responding to changes in solution's ionic strength as well as mobile phase flow rate and that the density of plasmid layer depends on the plasmid size and also loading conditions.

Purchase full article

Full view

H. P. Lesch, A. Laitinen, C. Peixoto, T. Vicente, K.-E. Makkonen, L. Laitinen, J. T. Pikkarainen

Gene Therapy advance online publication, 20 January 2011

Lentivirus can be engineered to be a highly potent vector for gene therapy applications. However, generation of clinical grade vectors in enough quantities for therapeutic use is still troublesome and limits the preclinical and clinical experiments. As a first step to solve this unmet need we recently introduced a baculovirus-based production system for lentiviral vector (LV) production using adherent cells. Herein, we have adapted and optimized the production of these vectors to a suspension cell culture system using recombinant baculoviruses delivering all elements required for a safe latest generation LV preparation. High-titer LV stocks were achieved in 293T cells grown in suspension. Produced viruses were accurately characterized and the functionality was also tested in vivo. Produced viruses were compared with viruses produced by calcium phosphate transfection method in adherent cells and polyethylenimine transfection method in suspension cells. Furthermore, a scalable and cost-effective capture purification step was developed based on a diethylaminoethyl monolithic column capable of removing most of the baculoviruses from the LV pool with 65% recovery.

Purchase full article

Full view

I. Gutierrez-Aguirrea, A. Steyer, M. Banjac, P. Kramberger, M. Poljšak-Prijatelj, M. Ravnikar

Journal of Chromatography A, 1218 (2011) 2368-2373

Rotaviruses are the leading cause of gastroenteritis in children and they exist widely in water environments. Ingestion of 10–100 viral particles is enough to initiate disease, what calls for extremely sensitive detection methods. In this study we have confirmed the validity of a recently published method for rotavirus concentration and detection based on the combination of methacrylate monoliths and real-time reverse transcription-quantitative PCR (RT-qPCR). The method was used to concentrate rotaviruses from different tap water and environmental water samples collected in Slovenia within years 2007 and 2009. The performance of virus concentration using monolithic supports was improved in comparison to the one of tangential ultrafiltration upon application of both methods on a range of environmental samples. Several samples were successfully concentrated on-site after successful adaptation of the method to field requirements. In such on-site format, the combination of concentration using CIM and detection using RT-qPCR detected as low as 30 rotavirus particles/ml, spiked in an environmental water sample.

Purchase full article

Full view

L. Urbas, B. Košir, M. Peterka, B. Pihlar, A. Štrancar, M. Barut

Journal of Chromatography A, 1218 (2011) 2432-2437

Monoliths are chromatographic stationary phases, which were specially designed for efficient purification of large biomolecules, like proteins, viruses and DNA. In this work, the small scale monolithic butyl (C4) and styrene-divinyl benzene (SDVB) columns were applied for reversed phase analyses of various degraded influenza viruses. The binding of the HA1 subunit of haemagglutinin to the monolithic columns was confirmed by sodium dodecyl sulphate-polyacrylamide gel electrophoresis (SDS-PAGE) and the Western blot. The working linear range was determined as 1.60 × 1010 viral particles/mL to at least 1.64 × 1011 viral particles/mL, the limit of detection was found to be 2.56 × 109 virus particles/mL and the limit of quantification was 5.12 × 109 virus particles/mL. The analytical HPLC method developed with the H1N1 virus was also applicable for the analytics of the HA1 subunit of H3N2 influenza virus and the influenza B virus.

Purchase full article

Full view

F. Smrekar, M. Ciringer, A. Štrancar, A. Podgornik

Journal of Chromatography A, 1218 (2011) 2438-2444

Binding of three different bacteriophages (phages), namely T7, lambda and M13 on methacrylate monoliths was investigated. Phage M13 exhibited the highest dynamic binding capacity of 4.5 × 1013 pfu/mL while T7 and lambda showed capacity of 1 × 1013 pfu/mL, all corresponding to values of around 1 mg/mL. Interestingly, capacity for lambda phage was increased 5-fold by increasing NaCl concentration in a loaded sample from 0 to 0.2 M while there was a constant capacity decrease for T7 and M13 phages. Under optimal conditions, recovery for all three phages approached 100%. Measurement of a pressure drop increase during loading enabled estimation of adsorbed phage layer thickness. At a maximal capacity it was calculated to be around 50 nm for T7 phage and 60 nm for lambda phage matching closely capside size thus indicating monolayer adsorption while 80 nm layer thickness was estimated for M13 phage showing its orientation along the pore.

Purchase full article

Full view

P. Kramberger, R. C. Honour, R. E. Herman, F. Smrekar, M. Peterka

Journal of Virological Methods 166 (2010) 60–64166 (2010) 60–64

Bacteriophages (phages) are known to be useful in many fields from medicine to agriculture, and for a broad range of applications, including phage therapy and phage display. For some applications, especially in medicine, high purity and viability of phages are required. Methacrylate monoliths (Convective Interaction Media [CIM] monolithic columns), designed for purification of bionanoparticles, were applied for the purification of Staphylococcus aureus phages VDX-10 from bacterial lysate. With a single step purification method, more than 99% of host cell DNA and more than 90% of proteins were removed, with 60% recovery of viable phages. Comparable results were obtained when the purification method was scaled-up from a CIM monolithic disk to a larger CIM monolithic column. Additionally, the dynamic binding capacity of a methacrylate monolith column for S. aureus phages VDX-10 was determined.

Purchase full article

Full view

M. Peterka, P. Kramberger, A. Štrancar

Wang, Perry G. (ur.). Monolithic chromatography and its modern applications. St Albans: ILM publications, 2010, pg. 489-508

Downstream processing (DSP) for purification can become a significant bottleneck in the production of novel biotherapeutics, such as viral vectors and vaccines (viral or DNA). Although different techniques can be used for the purification of large molecules and particles, liquid chromatography is the preferred method as it achieves the purity required by regulatory agencies. Despite the popularity of conventional chromatographic media, the diffusional mass transfer of large molecules and relatively small pore size remain limiting factors for the efficient separation of large biomolecules and particles.

Purchase book

Full view

2009

S. Yamamoto, M. Nakamura, C. Tarmann, A. Jungbauer

Journal of Chromatography A 1216 (2009) 2616-2620

Our previous study has shown that there is a good correlation between the number of charges of DNA (from trimer to 50-mer) and the number of binding sites B in electrostatic interaction chromatography (ion-exchange chromatography, IEC). It was also found that high salt (NaCl) concentration is needed to elute large DNAs (>0.6 M). In this paper we further performed experiments with large DNAs (up to 95-mer polyT and polyA) and charged liposome particles of different sizes (ca. 30, 50 and 100 nm) with a monolithic anion-exchange disk in order to understand the binding and elution mechanism of very large charged biomolecules or particles. The peak salt (NaCl) concentration increased with increasing DNA length. However, above 50-mer DNAs the value did not increase significantly with DNA length (ca. 0.65–0.70 M). For liposome particles of different sizes the peak salt concentration (ca. 0.62 M) was similar and slightly lower than that for large DNAs (ca. 0.65–0.70 M). The binding site values (ca. 25–30) are smaller than those for large DNAs. When arginine was used as a mobile phase modulator, the elution position of polyA and polyT became very close whereas in NaCl gradient elution polyT appeared after polyA eluted. This was mainly due to suppression of hydrophobic interaction by arginine.

Purchase full article

Full view

K. Kovač, I. Gutierrez-Aguirre, M. Banjac, M. Peterka, M. Poljšak-Prijatelj, M. Ravnikar, J. Zimšek Mijovski, A. C. Schultze, P. Raspor

Journal of Virological Methods 162 (2009) 272–275

Human enteric viruses are detected frequently in various types of environmental water samples, such as irrigation water, wastewater, recreational water, ground or subsurface water and even drinking water, constituting a primary source of gastroenteritis or hepatitis outbreaks. Only a few, but still infective number of viral particles are normally present in water samples, therefore an efficient virus concentration procedure is essential prior to molecular detection of the viral nucleic acid. In this study, a novel chromatographic technology, Convective Interaction Media® (CIM) monolithic supports, were optimized and applied to the concentration of hepatitis A virus (HAV) and feline calicivirus (FCV), a surrogate of norovirus (NoV), from water samples. Two-step real-time RT-qPCR was used for quantitation of the virus concentration in the chromatographic fractions. Positively charged CIM QA (quaternary amine) monolithic columns were used for binding of HAV and FCV present in previously inoculated 1.5 l bottled water samples. Column bound viruses were eluted from the monolith using 1 M NaCl to a final volume of 15 ml. Elution volume was concentrated further by ultracentrifugation. When the CIM/ultracentrifugation method was compared with another concentration method employing positively charged membranes and ultrafiltration, the recovery of HAV was improved by approximately 20%.

Purchase full article

Full view

E. I. Trilisky, H. Koku, K. J. Czymmek, A. M. Lenhoff

Journal of Chromatography A, 1216 (2009) 6365–6376

Commercially available polymer-based monolithic and perfusive stationary phases were evaluated for their applicability in chromatography of biologics. Information on bed geometry, including that from electron microscopy (EM), was used to interpret and predict accessible volumes, binding capacities, and pressure drops. For preparative purification of biologics up to at least 7 nm in diameter, monoliths and perfusive resins are inferior to conventional stationary phases due to their low binding capacities (20–30 g/L for BSA). For larger biologics, up to several hundred nanometers in diameter, calculations from EM images predict a potential increase in binding capacity to nearly 100 g/L. The accessible volume for adenovirus calculated from the EM images matched the experimental value. While the pores of perfusive resins are essentially inaccessible to adenovirus under binding conditions, under non-adsorbing conditions the accessible intrabead porosity is almost as large as the interbead porosity. Modeling of breakthrough curves showed that the experimentally observed slow approach to full saturation can be explained by the distribution of pore sizes.

Purchase full article

Full view

M. R. Etzel, W. T. Riordan

Jorunal of Chromatography A 1216 (2009) 2621-2624

Clearance of biological impurities is an essential part of the manufacture of biotechnology-derived products such as monoclonal antibodies (mAbs). Salt is required during manufacture to solubilize the mAb product and stabilize it against aggregation, but salt can be a problem later during impurity clearance operations. In this work, the use of a traditional quaternary amine (Q) monolith, and a new salt-tolerant monolith were evaluated for the clearance of pathogenic impurities including viruses, DNA, and host-cell protein (HCP). The impact of flow rate, salt concentration, and presence of mixtures of impurities in the feed stream were evaluated. Both monoliths cleared DNA to the limit of detection at all salt concentrations, and both cleared virus and HCP equally well at no salt. At intermediate salt, clearance of HCP was greater for the salt-tolerant monolith, and only the salt-tolerant monolith cleared virus at elevated salt. In conclusion, monoliths successfully trapped impurities such as DNA, host-cell protein, and viruses, and at flow rates far greater than traditional chromatography columns packed with beads.

Purchase full article

Full view

R. J. Whitfield, S. E. Battom, M. Barut, D. E. Gilham, P. D. Ball

Journal of Chromatography A, 1216 (2009) 2725-2729

To support effective process development there is a requirement for rapid analytical methods that can identify and quantitate adenoviral particles throughout the manufacturing process, from cellular lysate through to purified adenovirus. An anion-exchange high-performance liquid chromatography method for the analysis of adenovirus type 5 (Ad5) particles has been developed using a novel quaternary amine monolithic column (Bio-Monolith QA, Agilent). The developed method separates intact Ad5 from contaminating proteins and DNA, thus allowing analysis of non-purified samples during process development. Regeneration conditions were incorporated to extend the functional life of the column. Once developed, the method was qualified according to performance criteria of repeatability, intermediate precision and linearity. The linear working range of analysis was established between 7.5 × 108 to at least 2.4 × 1010 viral particles (3 × 1010 to 9.6 × 1011 viral particles/mL), with a correlation coefficient of 0.9992. Relative standard deviations (RSDs) for intra- and inter-day repeatability and precision for retention time and peak area were less than 1 and 2.5%, respectively.

Purchase full article

Full view

M. C. Cheeks, N. Kamal, A. Sorrel, D. Darling, F. Farzaneh, N. K. H. Slater

Journal of Chromatography A, 1216 (2009) 2705–2711

Histidine-tagged lentiviral vectors were separated from crude cell culture supernatant using labscale monolithic adsorbents by immobilized metal affinity chromatography. The capture capacity, concentration factor, purification factor, and elution efficiency of a supermacroporous cryogel monolith were evaluated against the Sartorius BIA Separations convective interaction media (CIM) disc, which is a commercial macroporous monolith. The morphology of the polymeric cryogel material was characterised by scanning electron microscopy. Iminodiacetic acid was used as the metal chelating ligand in both monoliths and the chelating capacity for metal ions was found to be comparable. The CIM-IDA-Ni2+ adsorbent had the greatest capture capacity (6.7 × 108 IU/ml of adsorbent), concentration factor (1.3-fold), and elution efficiency (69%). Advantages of the cryogel monoliths included rapid, low pressure processing as well low levels of protein and DNA in the final purified vector preparations.

Purchase full article

Full view

I. Gutiérrez-Aguirre, M. Banjac, A. Steyer, M. Poljšak-Prijatelj, M. Peterka, A. Štrancar, M. Ravnikar

Journal of Chromatography A, 1216 (2009) 2700–2704

Rotaviruses are the leading cause of diarrhoea in infants around the globe and, under certain conditions they can be present in drinking water sources and systems. Ingestion of 10–100 viral particles is enough to cause disease, emphasizing the need for sensitive diagnostic methods. In this study we have optimized the concentration of rotavirus particles using methacrylate monolithic chromatographic supports. Different surface chemistries and mobile phases were tested. A strong anion exchanger and phosphate buffer (pH 7) resulted in the highest recoveries after elution of the bound virus with 1 M NaCl. Using this approach, rotavirus particles spiked in 1 l volumes of tap or river water were efficiently concentrated. The developed concentration method in combination with a real time quantitative polymerase chain reaction assay detected rotavirus concentrations as low as 100 rotavirus particles/ml.

Purchase full article

Full view

2008

M. Ćurković Perica, I. Šola, L. Urbas, F. Smrekar, M. Krajačić

Journal of Chromatography A 1216 (2009) 2712-2716

A procedure based on Sartorius BIA Separations CIM DEAE anion-exchange chromatography was developed to separate double-stranded (ds) RNA of hypovirus infecting phytopathogenic fungus Cryphonectria parasitica. Using a linear gradient of 25 mM 4-morpholinepropanesulfonic acid (MOPS), pH 7.0 as a binding buffer, and 25 mM MOPS, 1.5 M NaCl, 0.1 mM EDTA, 15% isopropanol (v/v), pH 7.0 as an elution buffer, hypoviral dsRNA was additionally purified from nucleic acid species present in preparations partially purified by standard CF-11 cellulose chromatography. Moreover, crude phenol/chloroform extracts of the fungal tissue were also applied to monolithic supports and CIM DEAE chromatograms revealed clear evidence for hypoviral presence without CF-11 chromatography, nucleic acid precipitation, and electrophoresis.

Purchase full article

Full view

J. Ivancic-Jelecki, M. Brgles, M. Šantak, D. Forčić

Journal of Chromatography A 1216 (2009) 2717-2724

Human plasma is an important medical substance and a raw material for production of various therapeutics. During blood sampling, storage and processing, genomic DNA is released into plasma from nucleated blood cells that are damaged in the course of the procedure. In order to determine the concentration of contaminating DNA in plasma, we developed a method for DNA isolation by using anion-exchange chromatography on a Sartorius BIA Separations CIM (convective interaction media) diethylaminoethyl column. DNA was quantified by SYBR Green based real-time polymerase chain reaction. The concentration of cell-free, non-apoptotic DNA in plasma ranged between 0.06 and 22.5 ng/ml. As substantial volumes of plasma or whole blood are administered directly into the vascular system, a recipient is exposed to high amounts of cell-free DNA, several orders of magnitude higher than the amount found in other biologicals.

Purchase full article