Using Fingerprint HPLC Method to Develop and Control IgG (IVIG) From Cohn (I+II+III) Paste Production Process

The demand for human immunoglobulin is invariably increasing on an annual basis. To satisfy demands, different manufacturing processes are used to isolate immunoglobulins from human plasma. A quest for alternative paths in manufacturing not only requires development of the most economical manufacturing process, but also a rapid method development and development of reliable analytics for manufacturing monitoring. For an efficient improvement of the purification methods as well as for in-process control during manufacturing stage, the usage of reliable and fast analytical techniques are of crucial importance.

Fast and reliable fingerprint-based method for characterization of immunoglobulin G (IgG) prepared from Cohn I+II+III paste in two chromatographic steps is presented. The fingerprint method bases on partial separation of proteins in linear gradient on CIMac QA 0.1 mL column. Partial separation of proteins does not allow simple quantitative analysis of the samples during the IgG production from Cohn I + II + III paste, however, a very accurate qualitative information about the composition of the sample can be obtained in less than 5 minutes.