On May 12th, the biaseparations.com website will be retired and migrated tosartorius.com.Learn moreabout our combined offering today!
2016

Karla Mayolo-Deloisa, Jose Gonzalez-Valdez, and Marco Rito-Palomares
Biotechnol. Prog., 2016, Vol. 00, No. 00

Protein hydrophobicity can be modified after a PEGylation process. However, hydrophobic interaction chromatography (HIC) has been used to separate PEGylation reaction products less frequently than other techniques. In this context, chromatographic monoliths represent a good alternative to continue exploring the separation of PEGylated proteins with HIC. In this work, the separation of PEGylated proteins using C4 A monolith as well as Toyopearl Butyl 650C and Butyl Sepharose was analyzed. Three proteins were used as models: RNase A, b-lactoglobulin, and lysozyme. All proteins were PEGylated in the Nterminal amino groups with 20 kDa methoxy poly(ethylene glycol) propionaldehyde. The concentration of ammonium sulfate (1 M) used was the same for all stationary phases. The results obtained demonstrated that the C4 A monolith could better resolve all protein PEGylation reaction mixtures, since the peaks of mono- and di-PEGylated proteins can be clearly distinguished in the chromatographic profiles. On the contrary, while using Butyl Sepharose media only the PEGylation reaction mixtures of RNase A could be partially separated at 35 and 45 CVs. PEGylated proteins of b-lactoglobulin and lysozyme could not be resolved when Toyopearl Butyl 650C and Butyl Sepharose were used. It is then clear that monoliths are an excellent choice to explore the purification process of PEGylated proteins exploiting the advantages of HIC.

Download full article

Full view

Tarasova, I. A., Lobas, A. A., Černigoj, U., Solovyeva, E. M., Mahlberg, B., Ivanov, M. V., Panić-Janković, T., Nagy, Z., Pridatchenko, M. L., Pungor, A., Nemec, B., Vidič, U., Gašperšič, J., Krajnc, N. L., Vidič, J., Gorshkov, M. V. and Mitulović, G. ELECTROPHORESIS. Accepted Author Manuscript. doi:10.1002/elps.201500489.

Affinity depletion of abundant proteins such as human serum albumin (HSA) is an important stage in routine sample preparation prior to tandem mass spectrometry (MS/MS) analysis of biological samples with high range of concentrations. Due to the charge competition effects in electrospray ion source that results in discrimination of the low-abundance species, as well as limited dynamic range of MS/MS, restricted typically by three orders of magnitude, the identification of low-abundance proteins becomes a challenge unless the sample is depleted from high concentration compounds. This dictates a need for developing efficient separation technologies allowing fast and automated protein depletion. In this study we performed evaluation of a novel immunoaffinity-based CIMac depletion column with specificity to HSA (CIMac-αHSA). Because of the convective flow-through channels, the polymethacrylate CIMac monoliths afford flow rate-independent binding capacity and resolution that results in relatively short analysis time compared with traditional chromatographic supports. Seppro IgY14 depletion kit was used as a benchmark to control the results of depletion. Bottom-up proteomic approach followed by label-free quantitation using normalized spectral indexes were employed for protein quantification in G1/G2 and Cleavage/Blastocyst IVF culture media widely utilized in clinics for embryo growth in vitro. The results revealed approximately equal HSA level of 100% ± 25% in albumin-enriched fractions relative to the non-depleted samples for both CIMac-αHSA column and Seppro kit. In the albumin-free fractions concentrated 5.5-fold by volume, serum albumin was identified at the levels of 5 to 30% and 20 to 30% for the CIMac-αHSA and Seppro IgY14 spin columns, respectively.

Download full article

Full view

U. Cernigoj, U. Vidic, B. Nemec, J. Gaspersic, J. Vidic,N. L. Krajnc, A. Strancar, A. Podgornik. Journal of Chromatography A, 1464 (2016) 72–78

We investigated effect of immobilization procedure and monolith structure on chromatographic performance of methacrylate monoliths bearing affinity ligands. Monoliths of different pore size and variousaffinity ligands were prepared and characterized using physical and chromatographic methods. When testing protein A monoliths with different protein A ligand densities, a significant non linear effect ofligand density on dynamic binding capacity (DBC) for IgG was obtained and accurately described by Langmuir isotherm curve enabling estimation of protein A utilization as a function of ligand density. Maximal IgG binding capacity was found to be at least 12 mg/mL exceeding theoretical monolayer adsorption value of 7.8 mg/mL assuming hexagonal packing and IgG hydrodynamic diameter of 11 nm. Observed discrepancy was explained by shrinkage of IgG during adsorption on protein A experimentally determined through calculated adsorbed IgG layer thickness of 5.4 nm from pressure drop data. For monoliths with different pore size maximal immobilized densities of protein A as well as IgG dynamic capacitylinearly correlates with monolith surface area indicating constant ligand utilization. Finally, IgGs toward different plasma proteins were immobilized via the hydrazide coupling chemistry to provide oriented immobilization. DBC was found to be flow independent and was increasing with the size of bound protein. Despite DBC was lower than IgG capacity to immobilized protein A, ligand utilization was higher.

Download full article

Full view

2015

D. Buzzi, A. Štrancar

Chimica Oggi-Chemistry Today; Vol 33(1) January/February 2015

The importance of the monitoring of a process all along its steps by means of PAT has been defined by FDA in 2002. How can be defined the product quality and what are the parameters that should be checked by means of different analysis techniques, being focused in particular on the application of high pressure liquid chromatography techniques (HPLC) as high value tool for the process monitoring. From the first introduction of Process Analytical Technology to the "state of the art": how can be PAT implemented in order to ensure the final product quality.

Download full article

Full view

P. Kramberger, U. Lidija, A. Štrancar
Human Vaccines & Immunotherapeutics, 11:4 (2015) 1010-1021

Downstream processing of nanoplexes (viruses, virus-like particles, bacteriophages) is characterized by complexity of the starting material, number of purification methods to choose from, regulations that are setting the frame for the final product and analytical methods for upstream and downstream monitoring. This review gives an overview on the nanoplex downstream challenges and chromatography based analytical methods for efficient monitoring of the nanoplex production.

Download full article

Full view

L. Hernandez, D. Stewart, L. Zumalacarregui, D. Amaro
Chinese Journal of Chromatography A, 1000-8713 (2015) 642-646

Affinity and ion exchange conventional chromatography have been used to capture erythropoietin (EPO) from mammalian cell culture supernatant. Currently, chromatographic adsorbent perfusion is available, however a limited number of applications have been found in the literature. In this work, three anion exchange chromatographic supports (gel, membrane and monolithic) were evaluated in the capture step of the recombinant erythropoietin purification process. The influences of load and flow rate on each support performance were analyzed. Also the purity of the EPO molecules was determined. A productivity analysis, as a decision tool for larger scale implementation, was done. As a conclusion, the evaluated supports are technically suitable to capture EPO with adequate recovery and good purity. However, the monolithic column admits high operating velocity, showing the highest adsorption capacity and productivity.

Download full article

Full view

A. G. Lopes

FBP-461, Food and Bioproducts Processing (2014)

As the biopharmaceutical industry matures, the trend towards increased flexibility and productivity, faster time tomarket and greater profitability are driving the replacement of traditional stainless steel equipment by single-use technology (SUT). The use of SUT in the biopharmaceutical industry can significantly impact the manufacturing process efficiency by reducing capital costs, improving plant flexibility, reducing start-up times and costs, and elim-inating both non-value added process steps and the risk of cross-contamination. In addition it significantly reduces process liquid waste, labour costs and on-site quality and validation requirements. This paper reviews the current status of the technology and the impact of SUT in the biopharmaceutical industry, with the aim of identifying the challenges and limitations that still need to be addressed for further adoption of these technologies. Even tough SUT has a multitude of systems available, its components and assemblies have little standardisation as well as alack of harmonised tests and procedures among suppliers, with an array of guidelines from a variety of sourcesand no critical limits have been established. In addition, the use of SUT has new validation requirements such as leachables and extractables, suppliers’ qualification and SUT lot-to-lot variability. The lack of expertise in these areas and the new training requirements when using SUT also need to be addressed. To date the majority of the avail-able literature regarding SUT is found in trade journals where typically suppliers are the main contributors. There is still a lack of engagement of the academic community, which contributes to very limited scientific proof from independent peer-reviewed research to support performance of SUT. This is particularly the case during operation and integrity testing of SUT, during for example on-site testing, transport and disposal. Another area where no work has been undertaken concerns conceptual approaches for facility clean-room requirement and appropriate layout design using SUT. Investment in novel technologies, research, standardisation and training is paramount for further development and implementation of SUTs across all sectors of the biopharmaceutical industry.

Purchase full article

Full view

2014

P. Leblebici, M. E. Leblebici, F. Ferreira-da-Silva, A. E.Rodrigues, L. S. Pais
Journal of Chromatography B, 962 (2014) 89-93

Monolithic columns have attracted significant attention for the purification of large biomolecules. In the present study, a step gradient elution method was evaluated for the separation of human immunoglobulinG (hIgG) into its subclasses on CIM (convective interaction media) r-protein A (recombinant protein A)monolithic column. hIgG was loaded onto the column and bound protein was eluted with a pH gra-dient. The subclass content of the eluted fractions was analyzed by enzyme-linked immunosorbentassay (ELISA). Results showed that separation of IgG3 from the other three subclasses can be success-fully achieved with high selectivity (100%) and throughput on monolithic media. It was also revealedthat enriched fractions of IgG1 and IgG2 could be obtained from purified hIgG in a 28 min long chro-matographic run. Three fractions with high IgG1 content (89.1%, 94.3% and 88.8%) were recovered. Furthermore, IgG2 was enriched to 64% successfully. A rapid step gradient elution scheme without any additives in buffers was proven to obtain enriched preparations of the two important subclasses with high throughput. The separation time can be reduced even more by increasing the flow rate without anyloss in selectivity, which will be beneficial in industrial scale applications.

Download full article

Full view

M. M. St. Amand, B. A. Ogunnaike, A.S. Robinson

Published online in Wiley Online Library, 2013

One major challenge currently facing the biopharmaceutical industry is to understand how MAb microheterogeneity affects therapeutic efficacy, potency, immunogenicity, and clearance. MAb micro-heterogeneity can result from post-translational modifications such as sialylation, galactosylation, C-terminal lysine cleavage, glycine amidation, and tryptophan oxidation, each of which can generate MAb charge variants; such heterogeneity can affect pharmacokinetics (PK) considerably. Implementation of appropriate on-line quality control strategies may help to regulate bioprocesses, thus enabling more homogenous material with desired posttranslational modifications and PK behavior. However, one major restriction to implementation of quality control strategies is the availability of techniques for obtaining on-line or at line measurements of these attributes. In this work, we describe the development of an at-line assay to separate MAb charge variants in near real-time, which could ultimately be used to implement on-line quality control strategies for MAb production. The assay consists of a 2DHPLC method with sequential in-line Protein A and WCX-10 HPLC column steps. To perform the 2D-HPLC assay at-line, the two columns steps were integrated into a single method using
a novel system configuration that allowed parallel flow over column 1 or column 2 or sequential flow from column 1 to column 2. A bioreactor system was also developed such that media samples could be removed automatically from bioreactor vessels during production and delivered
to the 2D-HPLC for analysis. With this at-line HPLC assay, we have demonstrated that MAb microheterogeneity occurs throughout the cell cycle whether the host cell line is grown under different or the same nominal culture conditions.

Read full article

Full view

2013

A. A. Shukla, U. Gottschalk

Trends in Biotechnology (2012) 1-8

The manufacture of protein biopharmaceuticals is conducted under current good manufacturing practice (cGMP) and involves multiple unit operations for upstream production and downstream purification. Until recently, production facilities relied on the use of relatively inflexible, hard-piped equipment including large stainless steel bioreactors and tanks to hold product intermediates and buffers. However, there is an increasing trend towards the adoption of single-use technologies across the manufacturing process. Technical advances have now made an end-to-end single-use manufacturing facility possible, but several aspects of single-use technology require further improvement and are continually evolving. This article provides a perspective on the current state-of-the-art in single-use technologies and highlights trends that will improve performance and increase the market penetration of disposable manufacturing in the future.

Purchase full article

Full view

M. Li, Y. X. Qiu

Vaccine 31 (2013) 1264-1267

An effective downstream bio-processing of vaccine products requires complete chemical knowledge of the contaminants that may arise from a given vector expression system. Whether the vaccine is made from the traditional egg-based or the new cell-cultured process, it is the expression system that determines the types of impurities that need to be identified and removed from the vaccine product.

There are mechanical and chemical factors that can either reduce the yield or render a vaccine product to be irreversibly inactive. The choice of equipment and solvents is therefore important in minimizing product loss, and for maintaining an efficient and optimized manufacturing process.

The frequent out-of-specification, irreproducible data and inefficiency in the manufacturing of biologics were the basis for FDA to propose the “cGMP for the 21st Century” initiative in the year of 2000. Effective 2004, the concept of quality by design (QbD) has been imposed in the manufacturing of biologics. To facilitate the implementation of QbD FDA has encouraged the use of process analytical technology (PAT). Further, FDA believes that an optimized manufacturing scheme requires one to identify and to control the variables that can negatively affect the yield and quality of the desired product, and PAT can reveal wrongful data and alert the operator for immediate correction during processing.

Purchase full article

Full view

A. Martinčič, M. Cemazar, G. Sersa, V. Kovač, R. Milačič, J. Ščančar

Talanta 116 (2013)141-148

Conjoint liquid chromatography (CLC) on monolithic convective interaction media (CIM) disks coupled on-line to UV and inductively coupled plasma mass spectrometry (ICP-MS) detectors was used for the first time in speciation analysis of Pt in human serum spiked with Pt-based chemotherapeutics. CIM Protein G and CIM DEAE disks were assembled together in a single housing forming a CLC monolithic column. Such a set-up allows rapid two-dimensional separation by affinity and ion-exchange (IE) modes to be carried out in a single chromatographic run. By applying isocratic elution with Tris–HCl–NaHCO3 buffer (pH 7.4) in the first minute, followed by gradient elution with 1 mol L-1 NH4Cl (pH 7.4) in the next 9 min, immunoglobulins (IgG) were retained by the Protein G disk enabling subsequent separation of unbound Pt from Pt bound to transferrin (Tf) and albumin (HSA) on the CIM DEAE disk. Further elution with acetic acid (AcOH) in the next 3 min allowed separation of Pt associated with IgG. Separated Pt species were quantified by post-column isotope dilution—ICP-MS. Pt recovery on the CLC column was close to 100%. In comparison to commonly applied procedures that involve separation of protein peaks by size-exclusion chromatography (SEC) followed by IE separation of metal-based chemotherapeutic fractions bound to serum proteins, the CLC method developed is much faster and simpler. Its sensitivity (LOQs adequate for quantification of all separated Pt species, lower than 2.4 ng Pt mL-1), good selectivity and method repeatability (RSD±3%) enabled investigation of the kinetics of interaction of Pt-based chemotherapeutics with serum proteins and the distribution of Pt species in spiked human serum. Pt species present in spiked serum were bound preferentially to HSA. The proportion of Pt associated with IgG and Tf was lower than 13%. Cisplatin and especially oxaliplatin react rapidly with serum proteins, while carboplatin much less. The method developed may be reliably applied in preclinical and clinical studies of the kinetics of the interaction and distribution of different metallodrugs with proteins in blood serum.

Purchase full article

Full view

H. G. Schwelberger, J. Feurle, F. Ahrens

Journal of Neural Transmission 120 (2013) 983-986

Diamine oxidase (DAO) was purified to homogeneity from human seminal plasma by consecutive chromatographic fractionation on heparin-sepharose, phenyl-sepharose, CIM-QA, and Superdex 200. Human seminal plasma DAO behaves electrophoretically similar to DAO proteins from other human tissues and has very similar enzymatic properties with histamine and aliphatic diamines being the preferred substrates as well as significant conversion of polyamines. The cellular source and functional importance of DAO in human semen remain to be determined.

Purchase full article

Full view

O. Zitka, S. Skalickova, S. Krizkova, M. Vlkova, V. Adam, R. Kizek

Chromatographia (2013) 76:611-619

In this study, we optimized method for the isolation and detection of lactoferrin from human saliva using 3 mm short monolithic disc. We optimized the conditions for separation as flow rate 4 mL min-1 and ionic strength of effluent as 2 M·NaCl. We estimated limit of detection of whole method, which was hyphenated to the Bradford’s assay, down to 100 ng mL-1. The purity of the isolated fractions was verified by sodium dodecyl sulphate-polyacrylamide gel electrophoresis and recovery of isolation was found to be 51 % using minimally processed sample of saliva. Further, we tested the optimized method on group of healthy volunteers (n = 7). We were able to distinguish between the healthy subjects and subject suffering from celiac disease, which reported at least 2.5× higher level of lactoferrin in comparison to healthy ones. The results were correlated with standard enzyme-linked immunosorbent assay (ELISA) kit with obtained correlation coefficient R2 = 0.8446. Analysis of lactoferrin in saliva by monolithic disc and subsequent offline photometric detection is faster and cheaper method compared to ELISA commercial kit. The total analysis of one sample takes.

Purchase full article

Full view

D. A. Ribeiro, D. F. Passos, H. C. Ferraz, L. R. Castilho

Journal of Chromatography B, 938 (2013) 111-118

Both recombinant and plasma-derived factor IX concentrates are used in replacement therapies for the treatment of haemophilia B. In the present work, the capture step for a recombinant FIX (rFIX) purification process was investigated. Different strong anion-exchange chromatography media (the resins Q Sepharose® FF and Fractogel® TMAE, the monolith CIM® QA and the membrane adsorber Sartobind® Q) were tested for their rFIX binding capacity under dynamic conditions. In these experiments, crude supernatant from CHO cells was used, thus in the presence of supernatant contaminants and mimicking process conditions. The highest dynamic binding capacity was obtained for the monolith, which was then further investigated. To study pseudoaffinity elution of functional rFIX with Ca2+ ions, a design of experiments to evaluate the effects of pH, NaCl and CaCl2 on yield and purification factor was carried out. The effect of pH was not statistically significant, and a combination of no NaCl and 45 mM CaCl2 yielded a good purification factor combined with a high yield of active rFIX. Under these conditions, activity yield of rFIX was higher than the mass yield, confirming selective elution of functional, γ-carboxylated rFIX. Scaling-up of this process 8 fold resulted in very similar process performance. Monitoring of the undesired activated FIX (FIXa) revealed that the FIXa/FIX ratio (1.94%) was higher in the eluate than in the loaded sample, but was still within an acceptable range. HCP and DNA clearances were high (1256 and 7182 fold, respectively), indicating that the proposed process is adequate for the intended rFIX capture step.

Purchase full article

Full view

J. A. Martin, P. Parekh, Y. Kim, T. E. Morey, K. Sefah, N. Gravenstein, D. M. Dennis, W. Tan

PLOS ONE, March 2013, Volume 8, Issue 3, e57341

Adverse drug reactions, including severe patient bleeding, may occur following the administration of anticoagulant drugs. Bivalirudin is a synthetic anticoagulant drug sometimes employed as a substitute for heparin, a commonly used anticoagulant that can cause a condition called heparin-induced thrombocytopenia (HIT). Although bivalrudin has the advantage of not causing HIT, a major concern is lack of an antidote for this drug. In contrast, medical professionals can quickly reverse the effects of heparin using protamine. This report details the selection of an aptamer to bivalirudin that functions as an antidote in buffer. This was accomplished by immobilizing the drug on a monolithic column to partition binding sequences from nonbinding sequences using a low-pressure chromatography system and salt gradient elution. The elution profile of binding sequences was compared to that of a blank column (no drug), and fractions with a chromatographic difference were analyzed via real-time PCR (polymerase chain reaction) and used for further selection. Sequences were identified by 454 sequencing and demonstrated low micromolar dissociation constants through fluorescence anisotropy after only two rounds of selection. One aptamer, JPB5, displayed a dose-dependent reduction of the clotting time in buffer, with a 20 µM aptamer achieving a nearly complete antidote effect. This work is expected to result in a superior safety profile for bivalirudin, resulting in enhanced patient care.

Read full article

Full view

E. Maksimova, E. Vlakh, E. Sinitsyna, T. Tennikova
J. Sep. Sci. 2013, 36, 3741–3749

Ultrashort monolithic columns (disks) were thoroughly studied as efficient stationary phases for precipitation–dissolution chromatography of synthetic polymers. Gradient elution mode was applied in all chromatographic runs. The mixtures of different flexible chain homopolymers, such as polystyrenes, poly(methyl methacrylates), and poly(tert-butylmethacrylates) were separated according to their molecular weights on both commercial poly(styrene-co divinylbenzene).
disks (12 id × 3 mm and 5 × 5 mm) and lab-made monolithic columns (4.6 id × 50 mm) filled with supports of different hydrophobicity. The experimental conditions were optimized to reach fast and highly efficient separation. It was observed that, similar to the separation of monoliths of other classes of (macro)molecules (proteins, DNA, oligonucleotides), the length of column did not affect the peak resolution.
A comparison of the retention properties of the poly(styrene-co-divinylbenzene) diskshaped monoliths with those based on poly(lauryl methacrylate-co-ethylene dimethacrylate), poly(butyl methacrylate-co-ethylene dimethacrylate), and poly(glycidyl methacrylate-co-ethylene dimethacrylate) supports demonstrated the obvious effect of surface chemistry on the resolution factor. Additionally, the results of the discussed chromatographic mode on the fast determination of the molecular weights of homopolymers used in this study were compared to those established by SEC on columns packed with sorbent beads of a similar nature to the monoliths.

Purchase full article

Full view

Roy N D‘Souza, Ana M Azevedo, M Raquel Aires-Barros, Nika Lendero Krajnc, Petra Kramberger, Maria Laura Carbajal, Mariano Grasselli, Roland Meyer & Marcelo Fernández-Lahore

Vol. 1, No. 5, Pharmaceutical Bioprocessing (2013)

Downstream processing is currently the major bottleneck for bioproduct generation. In contrast to the advances in fermentation processes, the tools used for downstream processes have struggled to keep pace in the last 20 years. Purification bottlenecks are quite serious, as these processes can account for up to 80% of the total production cost. Coupled with the emergence of new classes of bioproducts, for example, virus-like particles or plasmidic DNA, this has created a great need for superior alternatives. In this review, improved downstream technologies, including aqueous two-phase systems, expanded bed adsorption chromatography, convective flow systems, and fibre-based adsorbent systems, have been discussed. These adaptive methods are more suited to the burgeoning downstream processing needs of the future, enabling the cost-efficient production of new classes biomaterials with a high degree of purity, and thereby hold the promise to become indispensable tools in the pharmaceutical and food industries.

Purchase full article

Full view

2012

J. Lee, H. T. Gan, S. M. Abdul Latiff , C. Chuah, W. Y. Lee, Y.-S. Yang, B. Loo, S. K. Ng, P. Gagnon

Journal of Chromatography A, 1270 (2012) 162-170

We introduce a chromatography method for purification of large proteins and viruses that works by capturing them at a non-reactive hydrophilic surface by their mutual steric exclusion of polyethylene glycol (PEG). No direct chemical interaction between the surface and the target species is required. We refer to the technique as steric exclusion chromatography. Hydroxyl-substituted polymethacrylate monoliths provide a hydrophilic surface and support convective mass transport that is unaffected by the viscosity of the PEG. Elution is achieved by reducing PEG concentration. Selectivity correlates with molecular size, with larger species retained more strongly than smaller species. Retention increases with PEG size and concentration. Salts weaken retention in proportion to their concentration and Hofmeister ranking. Retention is enhanced near the isoelectric point of the target species. Virus binding capacity was measured at 9.9 × 1012 plaque forming units per mL of monolith. 99.8% of host cell proteins and 93% of DNA were eliminated. Mass recovery exceeded 90%. IgM capacity was greater than 60 mg/mL. 95% of host cell proteins were eliminated from IgM produced in protein-free media, and mass recovery was up to 90%. Bioactivity was fully conserved by both viruses and antibodies. Process time ranged from less than 30 min to 2 h depending on the product concentration in the feed stream.

Purchase full article

Full view

C. Scott

BioProcess International, November 2012, pg. 31-42

Monoclonal antibodies (MAbs) remain the largest segment of the biopharmaceutical market, but they are not the only recombinant proteins in development. Remember that the first biopharmaceutical approved for sale was recombinant insulin — a hormone — back in the 1980s. And proteins aren't the only recombinant biologics. The sector has expanded since then to include gene therapies and viral vectors, vaccines, and even cells and tissues. Companies around the world are developing such products for cancer, neurological, infectious disease, metabolic, autoimmune, and cardiovascular disorders, to name just the most prominent. And although MAbs are finally fulfilling their “magic bullet” promise, many other approaches are becoming available to drug developers targeting those markets — and others.

Meanwhile, funding challenges are increasing emphasis on manufacturing and development efficiencies. Even though total funding of the biotechnology industry has rebounded since the 2008 recession — from about US$13 billion for the United States industry in 2008 to about $21 billion in 2010, for example — a growing share of that money is going to the less risky investments. According to Ernst & Young's 2011 Beyond Borders report, that means mature and already-profitable companies are taking a larger portion of the financial pie.

At the same time, the average number of drug approvals per year has decreased: from about three dozen in the United States from 1996 to 2004 to under two dozen for the years since. And even though markets are opening up in China, India, and other countries, the cost of doing business on a global scale makes it no easy task to reach them. So biopharmaceutical companies need to curb the rise of development and manufacturing costs. Single-use technologies are helping with the latter in large part. And platform technologies have helped antibody makers shorten development times by starting out with certain rules of thumb — rather than trying out hundreds of available purification technologies, for example, in many different combinations to find what works best for every new product candidate.

Do nonantibody makers have similar options when it comes to their own process development work? As is so often the case in bioprocessing, the answer to that question is “It depends. ..” on the product class; on the expression system; and on the regulatory history of the company, process, and type of molecule.

Read full article

Full view