On May 12th, the biaseparations.com website will be retired and migrated tosartorius.com.Learn moreabout our combined offering today!
2023

Irena Trbojević-Akmačić, Frano Vučković,Tea Pribić, Marija Vilaj, Urh Černigoj, Jana Vidič, Jelena Šimunović, Agnieszka Kępka, Ivana Kolčić, Lucija Klarić, Mislav Novokmet, Maja Pučić-Baković, Erdmann Rapp, Aleš Štrancar, Ozren Polašek, James F. Wilson and Gordan Lauc 

Communications Biology volume 6, Article number: 312 (2023)

Human plasma transferrin (Tf) N-glycosylation has been mostly studied as a marker for congenital disorders of glycosylation, alcohol abuse, and hepatocellular carcinoma. However, inter-individual variability of Tf N-glycosylation is not known, mainly due to technical limitations of Tf isolation in large-scale studies. Here, we present a highly specific robust high-throughput approach for Tf purification from human blood plasma and detailed characterization of Tf N-glycosylation on the level of released glycans by ultra-high-performance liquid chromatography based on hydrophilic interactions and fluorescence detection (HILIC-UHPLC-FLD), exoglycosidase sequencing, and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS). We perform a large-scale comparative study of Tf and immunoglobulin G (IgG) N-glycosylation analysis in two human populations and demonstrate that Tf N-glycosylation is associated with age and sex, along with multiple biochemical and physiological traits. Observed association patterns differ compared to the IgG N-glycome corroborating tissue-specific N-glycosylation and specific N-glycans’ role in their distinct physiological functions.

Download full article

Full view

2022

Katarina Markovič, Maja Cemazar, Gregor Sersa, Radmila Milačič and Janez Sčančar

Journal of Analytical Atomic Spectrometry

Ceruloplasmin (Cp) is the major copper-carrying (Cu) protein in human plasma. Due to copper's important physiological functions and its role in various diseases, there is a need to quantify the concentration bound to Cp and the exchangeable form of Cu. In the present work, conjoint liquid chromatography (CLC) on short-bed convective interaction media (CIM) monolithic disks was used to separate the Cu bound to low molecular mass (LMM) species, and the Cu bound to Cp and albumin (HSA) in human serum. Two immunoaffinity CIMmic albumin depletion (α-HSA) disks and one CIMmic weak anion-exchange diethylaminoethyl (DEAE) disk were assembled in a single housing, forming a CLC monolithic column. By applying isocratic elution with a 50 mmol L−1 MOPS buffer (pH 7.4) in the first 3 min, followed by gradient elution with 1 mol L−1 NH4Cl (pH 7.4) in the next 9 min, HSA was retained by the α-HSA disk, allowing subsequent separation of the LMM-Cu from the Cu bound to the Cp on the DEAE disk. Further elutio with 0.5 mol L−1 acetic acid in the next 4 min rinsed the HSA from the α-HSA disk. The separated Cu species were quantified by post column isotope dilution inductively coupled plasma mass spectrometry (ID-ICP-MS), while the elution profile of the proteins was followed by UV detection at 278 nm. Quantitative column recoveries were obtained. Good repeatability of the measurement was achieved for Cu-Cp (±1%), while for Cu-HSA and Cu-LMM species the repeatability of the measurements was slightly worse, due to the much lower Cu concentrations (±6% and ±9%, respectively). The developed method required only 20 μL of a 15-times diluted sample. Low limits of detection for the Cu-Cp, Cu-HSA and Cu-LMM species (6.1, 5.3 and 3.3 ng mL−1 Cu, respectively) were obtained. The technique was successfully applied in the determination of Cu-Cp, Cu-HSA and a fraction that most probably corresponds to the Cu-LMM species in the human serum of healthy individuals, kidney transplant patients and cancer patients.

Download full article

Full view

2021

Thanaporn Liangsupree, Evgen Multia, Marja-Liisa Riekkola

Journal of Chromatography A, Volume 1636, 2021

Abstract

Extracellular vesicles (EVs) are heterogenous membrane-bound vesicles released from various origins. EVs play a crucial role in cellular communication and mediate several physiological and pathological processes, highlighting their potential therapeutic and diagnostic applications. Due to the rapid increase in interests and needs to elucidate EV properties and functions, numerous isolation and separation approaches for EVs have been developed to overcome limitations of conventional techniques, such as ultracentrifugation. This review focuses on recently emerging and modern EV isolation and separation tech- niques, including size-, charge-, and affinity-based techniques while excluding ultracentrifugation and precipitation-based techniques due to their multiple limitations. The advantages and drawbacks of each technique are discussed together with insights into their applications. Emerging approaches all share sim- ilar features in terms of being time-effective, easy-to-operate, and capable of providing EVs with suitable and desirable purity and integrity for applications of interest. Combination and hyphenation of techniques have been used for EV isolation and separation to yield EVs with the best quality. The most recent de- velopment using an automated on-line system including selective affinity-based trapping unit and asym- metrical flow field flow fractionation allows reliable isolation and fractionation of EV subpopulations from human plasma.

Attachments

Full view

Petrović T, Alves I, Bugada D, Pascual J, Vučković F, Skelin A, Gaifem J, Villar-Garcia J, Vicente MM, Fernandes Â, Dias AM, Kurolt IC, Markotić A, Primorac D, Soares A, Malheiro L, Trbojević-Akmačić I, Abreu M, Sarmento E Castro R, Bettinelli S, Callegaro A, Arosio M, Sangiorgio L, Lorini LF, Castells X, Horcajada JP, Pinho SS, Allegri M, Barrios C, Lauc G.

Glycobiology. 2020 Nov.

Abstract:

A large variation in the severity of disease symptoms is one of the key open questions in COVID-19 pandemics. The fact that only a small subset of people infected with SARS-CoV-2 develop severe disease suggests that there have to be some predisposing factors, but biomarkers that reliably predict disease severity have not been found so far. Since overactivation of the immune system is implicated in a severe form of COVID-19 and the IgG glycosylation is known to be involved in the regulation of different immune processes, we evaluated the association of inter-individual variation in IgG N-glycome composition with the severity of COVID-19. The analysis of 166 severe and 167 mild cases from hospitals in Spain, Italy and Portugal revealed statistically significant differences in the composition of the IgG N-glycome. The most notable difference was the decrease in bisecting Nacetylglucosamine (GlcNAc) in severe patients from all three cohorts. IgG galactosylation was also lower in severe cases in all cohorts, but the difference in galactosylation was not statistically significant after correction for multiple testing. To our knowledge, this is the first study exploring IgG N-glycome variability in COVID-19 severity.

Download full article

Full view

2020

by Simon Staubach, Pete Gagnon, Katja Vrabec, Tjaša Lojpur, Sebastijan Peljhan, Bernd Giebel and Aleš Štrancar

BioProcess International, 2020

Abstract:

The traditional classification of extracellular vesicles (EVs) includes three types: exosomes, microvesicles, and apoptotic vesicles. Each type arises from a distinct origin and exhibits distinct characteristics. The problem is that their size ranges overlap and that the major surface proteins presented by exosomes also are present on the surfaces of microvesicles and apoptotic bodies. This makes it a challenge for process developers to identify the vesicle fraction that best serves a particular exosome therapy. Anion-exchange chromatography (AEC) can fractionate EVs into populations of different composition. This article highlights the complementarity of two analytical methods for characterizing distinctions among EV populations separated by AEC: imaging flow cytometry (IFCM) and size-exclusion chromatography.

Download full eBook

Full view

E. Multia, T. Liangsupree, M. Jussila, J. Ruiz-Jimenez, M. Kemell and M. Riekkola

Analytical Chemistry, 2020

Abstract:

An automated on-line isolation and fractionation system including controlling software was developed for selected nanosized biomacromolecules from human plasma by on-line coupled immunoaffinity chromatography asymmetric flow field-flow fractionation (IAC-AsFlFFF). The on-line system was versatile, only different monoclonal antibodies, anti-apolipoprotein B-100, anti-CD9, or anti-CD61, were immobilized on monolithic disk columns for isolation of lipoproteins and extracellular vesicles (EVs). The platelet-derived CD61-positive EVs and CD9-positive EVs, isolated by IAC, were further fractionated by AsFlFFF to their sizebased subpopulations (e.g., exomeres and exosomes) for further analysis. Field-emission scanning electron microscopy elucidated the morphology of the subpopulations, and 20 free amino acids and glucose in EV subpopulations were identified and quantified in the ng/mL range using hydrophilic interaction liquid chromatography-tandem mass spectrometry (HILIC-MS/MS). The study revealed that there were significant differences between EV origin and size-based subpopulations. The on-line coupled IAC-AsFlFFF system was successfully programmed for reliable execution of 10 sequential isolation and fractionation cycles (37−80 min per cycle) with minimal operator involvement, minimal sample losses, and contamination. The relative standard deviations (RSD) between the cycles for human plasma samples were 0.84−6.6%.

Attachments

Full view

M. Morani, T.Duc Mai, Z. Krupova, P. Defrenaix, E. Multia, M. Riekkola, M. Taverna

Analytica Chimica Acta 1128 (2020) 45-51

Abstract

This work reports on the development of the first capillary electrophoresis methodology for the elucidation of extracellular vesicles’ (EVs) electrokinetic distributions. The approach is based on capillary electrophoresis coupled with laser-induced fluorescent (LIF) detection for the identification and quantification of EVs after their isolation. Sensitive detection of these nanometric entities was possible thanks to an ‘inorganic-species-free’ background electrolyte. This electrolyte was made up of weakly charged molecules at very high concentrations to stabilize EVs, and an intra-membrane labelling approach was used to prevent EV morphology modification. The limit of detection for EVs achieved using the developed CE-LIF method method reached 8 × 10⁹ EVs/mL, whereas the calibration curve was acquired from 1.22 × 10¹⁰ to 1.20 × 10¹¹ EVs/mL. The CE-LIF approach was applied to provide the electrokinetic distributions of various EVs of animal and human origins, and visualize different EV subpopulations from our recently developed high-yield EV isolation method.

Purchase full article

Full view

Pete Gagnon, Katja Vrabec, Tjaša Lojpur, and Aleš Štrancar

BioProcess International, 18 (4) April 2020

Abstract

Exosomes are a subject of rapidly growing therapeutic interest in the biopharmaceutical industry for two principal reasons. The first reason is that they are the primary communicators of instructions from source cells to target cells. Exosome surface features define their destination. They recognize complementary features on target cells, dock with them, and deliver their programmed instructions in the form of microRNA. The second reason is that exosomes are immunologically silent. As normal human cell products, and by contrast with gene therapy vectors such as virus particles, exosomes bypass the issue of triggering an immune response that might interfere with therapy.

Source cells include stem cells, which is why exosomes are of particular interest in the field of regenerative medicine. Recent research documenting the ability of exosomes to reverse the effects of severe strokes highlights their potential. It also underlines the need for scalable purification technology to advance these products through clinical trials and on to licensed manufacture. A platform approach was a major factor in the initial and continuing success of monoclonal antibodies. Exosomes likewise represent an extended family of individual products with similar properties. It stands to reason that a platform approach will prove equally valuable for exosomes. In this article we describe initial efforts toward that goal.

Contact us and request full article

Full view

2019

Calef Sánchez-Trasviña, Marco Rito-Palomares, and José González-Valdez

Advances in Polymer Technology, Volume 2019, December 12 2019, 10 pages

Abstract

PEGylated or polyethylene glycol-modified proteins have been used as therapeutic agents in different diseases. However, the major drawback in their procurement is the purification process to separate unreacted proteins and the PEGylated species. Several efforts have been done to separate PEGylation reactions by chromatography using different stationary phases and modified supports. In this context, this study presents the use of chromatographic monoliths modified with polyethylene glycol (PEG) to separate PEGylated Ribonuclease A (RNase A). To do this, Convective Interaction Media (CIM) Ethylenediamine (EDA) monolithic disks were PEGylated using three PEG molecular weights (1, 10, and 20 kDa). The PEGylated monoliths were used to separate PEGylated RNase A modified, as well, with three PEG molecular weights (5, 20, and 40 kDa) by hydrophobic interaction chromatography. Performance results showed that Bovine Serum Albumin (BSA) can bind to PEGylated monoliths and the amount of bound BSA increases when ammonium sulfate concentration and flow rate increase. Furthermore, when PEGylated RNase A was loaded into the PEGylated monoliths, PEG-PEG interactions predominated in the separation of the different PEGylated species (i.e., mono and di-PEGylated). It was also observed that the molecular weight of grafted PEG chains to the monolith impacts strongly in the operation resolution. Interestingly, it was possible to separate, for the first time, isomers of 40 kDa PEGylated RNase A by hydrophobic interaction chromatography. This technology, based on PEGylated monoliths, represents a new methodology to efficiently separate proteins and PEGylated proteins. Besides, it could be used to separate other PEGylated molecules of biopharmaceutical or biotechnological interest.

Read full article

Full view

Katarina Marković, Radmila Milačič, Janja Vidmar, Stefan Marković, Katja Uršič, Martina Nikšić Žakeljc, Maja Cemazar, Gregor Sersa, Mojca Unk, Janez Ščančar

Journal of Trace Elements in Medicine and Biology, Volume 57, January 2020, Pages 28-39.

Abstract

Monolithic chromatography using convective interaction media (CIM) disks or columns can be used in the separation step of speciation analysis. When different monolithic disks are placed in one housing, forming conjoint liquid chromatography (CLC) monolithic column, two-dimensional separation is achieved in a single chromatographic run. Here, we assembled low-pressure (maximum 50 bar) CLC monolithic column, which consists of two 0.34 mL shallow CIM monolithic disks and high-pressure CLC column (maximum 150 bar) from 0.1 mL analytical high performance short bed CIMac monolithic disks. The data from analyses showed that both tested CLC monolithic columns gave statistically comparable results, with the low-pressure CLC column exhibiting better resolving power and robustness. Low-pressure CLC column exhibited greater potential than high-pressure CLC column, and can be thus recommended for its intended use in speciation analysis of metal-based biomolecules.

Keywords: low-pressure and high-pressure conjoint liquid chromatography, anion-exchange and affinity monolithic disks, inductively coupled plasma mass spectrometry, Pt-based chemotherapeutics, serum of cancer patients

Read full article

Full view

Evgen Multia, Crystal Jing Ying Tear, Mari Palviainen, Pia Siljander, Marja-Liisa Riekkola

Analytica Chimica Acta (2019).
Published online 2019 Sep 11.

A new, fast and selective immunoaffinity chromatographic method including a methacrylate-based convective interaction media (CIM®) disk monolithic column, immobilized with anti-human CD61 antibody, was developed for the isolation of CD61-containing platelet-derived extracellular vesicles (EVs) from plasma. The isolated EVs were detected and size characterized by asymmetrical flow field-flow fractionation (AsFlFFF) with multi-angle light-scattering (MALS) and dynamic light-scattering (DLS) detection, and further confirmed by nanoparticle tracking analysis (NTA) and transmission electron microscopy (TEM). The isolation procedure took only 19 min and the time can be even further decreased by increasing the flow rate. The same immunoaffinity chromatographic procedure, following AsFlFFF allowed also the isolation and characterization of platelet-derived EVs from plasma in under 60 min. Since it is possible to regenerate the anti-CD61 disk for multiple uses, the methodology developed in this study provides a viable substitution and addition to the conventional EV isolation procedures.

Keywords: Immunoaffinity chromatography, Isolation, Monolithic disk column, Extracellular vesicles, Platelet-derived vesicles, CD61

Read full article

Full view

J. R. Lorsch, A. M. Munoz, J. S. Nanda, V. Rajagopal, P. Yourik, S. E. Walker

RNA Biology (2017), volume 14 (2), pp. 188–196.
Published online 2016 Dec 16.

In vitro studies of translation provide critical mechanistic details, yet purification of large amounts of highly active eukaryotic ribosomes remains a challenge for biochemists and structural biologists. Here, we present an optimized method for preparation of highly active yeast ribosomes that could easily be adapted for purification of ribosomes from other species. The use of a nitrogen mill for cell lysis coupled with chromatographic purification of the ribosomes results in 10-fold-increased yield and less variability compared with the traditional approach, which relies on sedimentation through sucrose cushions. We demonstrate that these ribosomes are equivalent to those made using the traditional method in a host of in vitro assays, and that utilization of this new method will consistently produce high yields of active yeast ribosomes.

KEYWORDS: Eukaryotic translation, in vitro translation, ribosome, ribosome purification, yeast

Read full article

Full view

Thanaporn Liangsupree, Evgen Multia, Jari Metso, Matti Jauhiainen, Patrik Forssén, Torgny Fornstedt, Katariina Öörni, Aleš Podgornik & Marja-Liisa Riekkola 

Scientific Reports, volume 9, August 2019

Low-density lipoprotein (LDL) is considered the major risk factor for the development of atherosclerotic cardiovascular diseases (ASCVDs). A novel and rapid method for the isolation of LDL from human plasma was developed utilising affinity chromatography with monolithic stationary supports. The isolation method consisted of two polymeric monolithic disk columns, one immobilized with chondroitin-6-sulfate (C6S) and the other with apolipoprotein B-100 monoclonal antibody (anti-apoB-100 mAb). The first disk with C6S was targeted to remove chylomicrons, very-low-density lipoprotein (VLDL) particles, and their remnants including intermediate-density lipoprotein (IDL) particles, thus allowing the remaining major lipoprotein species, i.e. LDL, lipoprotein(a) (Lp(a)), and high-density lipoprotein (HDL) to flow to the anti-apoB-100 disk. The second disk captured LDL particles via the anti-apoB-100 mAb attached on the disk surface in a highly specific manner, permitting the selective LDL isolation. The success of LDL isolation was confirmed by different techniques including quartz crystal microbalance. In addition, the method developed gave comparable results with ultracentrifugation, conventionally used as a standard method. The reliable results achieved together with a short isolation time (less than 30 min) suggest the method to be suitable for clinically relevant LDL functional assays.

Read full article

Full view

This discussion introduces new analytical approaches that enable in-line chromatographic detection of exosomes. One approach can discriminate extracellular vesicles from nonvesicle contaminants, and one potentially can discriminate exosomes from other vesicles. Examples illustrate how they enable development of more effective and better documented purification methods. The special qualifications of monolithic chromatography media for exosome purification are discussed. New process tools designed to accommodate some of the special challenges of exosome purification are introduced.

Feel free to download the eBook by clicking on the link to attachment below.

Attachments

Full view

2018

The purpose of this book is to provide you with a guide to developing monoclonal antibody purification procedures taht meet the requirements of both research and commercial applications. It is based on successful purifications developed for over 250 monoclonal-based products, addressing a wide range of diagnostic and therapeutic applications. it is supported by nearly 1000 citations from the scientific literature and enriched by the insights of skilled practitioners from throught the industry. It incorporates over 100 figures and tables to illustrate key concepts.

Attachments

Full view

2017

Marina Naldi, Urh Černigoj, Ales Štrancar, Manuela Bartolini

Reducing experimental variability, limiting contamination and increasing automation are essential goals in the development of reliable analytical platforms for mass spectrometry (MS)-based proteomics. In this work novel trypsin-based monolithic immobilized enzyme reactors (tryp-IMERs), obtained by covalent immobilization on convective interaction media (CIMac™) analytical columns (5 mm×5.2 mm I.D.), were developed. Notwithstanding the small dimensions, column format allowed the insertion in common high performance liquid chromatography (HPLC) systems, thus avoiding the use of expensive micro- or nano-platforms. Monolith pore diameter and surface chemistry were optimized to achieve high digestion efficiency even with high molecular weight proteins and to avoid protein/peptide adsorption, peak broadening and sample loss. A full characterization of the tryp-IMERs was undertaken to select the best protocol for preparation and type of trypsin. Optimization of the operational and storage conditions was carried out by an off-line approach. On-line studies were performed by setting a multidimensional analytical platform, which included the tryp-IMER, a trapping column, an analytical C4 column and a high resolution hybrid mass spectrometer (ESI-Q-TOF). In the optimized conditions rapid protein digestion (90 ± 9 s), high protein coverage (≥60%) and high score values were achieved for five selected sample proteins (cytochrome c, myoglobin and albumins from different sources) differing in molecular size, isoelectric point and accessibility to cleavage sites as well as for a protein mixture of 200 ng. The best performing tryp-IMERs showed high sensitivity down to the pmole level. The platform also resulted suitable for the analysis of high-molecular weight proteins such as a pool of human immunoglobulins G (hIgG) and for the high molecular weight fraction of human plasma proteins, which were digested in less than two minutes to an extent similar to that achieved by overnight incubation in a classical in solution protocol. Finally, underestimated key procedural issues were also highlighted during the study. Such aspects are of general interest both for tryp-IMER users and tryp-IMER developers.

Purchase full article

Full view

Sebastijan Peljhan, Tina Jakop, Dunja Šček, Vid Skvarča, Blaž Goričar, Romina Žabar, Nina Mencin. Electrophoresis 2017 July 20

The plasma-derived IgG used either for diagnostic purpose or intravenous application (in form of IVIG) in various medical therapies is certainly gaining more and more attention on annual basis. Different manufacturing processes are used to isolate immunoglobulins from human plasma. However, a quest for alternative paths in IgG isolation not only requires development of the most efficient isolation process, but also a rapid and reliable analytics to track the purification. Fast and reliable fingerprint based method for characterization of IgG prepared from Cohn I+II+III paste is presented in this paper. The fingerprint method bases on partial separation of proteins in linear gradient on CIMacTM quaternary amine, strong anion exchange group (QA) 0.1 mL column. Partial separation of proteins does not allow simple quantitative analysis of the samples during the IgG isolation from Cohn I+II+III fraction paste, but very accurate qualitative information about the composition of the sample can be obtained in less than 5 min. From the differences in the chromatograms of various samples, the ratio between IgG and impurities in each sample can be easily assessed. The method is suitable for input material control, in-line monitoring of the downstream processing, final control of the products, as well as in stability studies and enables taking fast and accurate decisions during fractionation process.

 Purchase full article.

Full view

2016

M. Naldi, M. Baldassarre, M. Domenicali, F. A. Giannone, M. Bossic, J. Montomoli,T. D. Sandahl, E. Glavind, H. Vilstrup, P. Caraceni, C. Bertucci
Journal of Pharmaceutical and Biomedical Analysis, Volume 122 (2016) 141-147

Human serum albumin (HSA) is the most abundant plasma protein, endowed with several biological properties unrelated to its oncotic power, such as antioxidant and free-radicals scavenging activities, binding and transport of many endogenous and exogenous substances, and regulation of endothelial function and inflammatory response. These non-oncotic activities are closely connected to the peculiarly dynamic structure of the albumin molecule. HSA undergoes spontaneous structural modifications, mainly by reaction with oxidants and saccharides; however, patients with cirrhosis show extensive post-transcriptional changes at several molecular sites of HSA, the degree of which parallels the severity of the disease. The present work reports the development and application of an innovative LC–MS analytical method for a rapid and reproducible determination of the relative abundance of HSA isoforms in plasma samples from alcoholic hepatitis (AH) patients. A condition of severe oxidative stress, similar to that observed in AH patients, is associated with profound changes in circulating HSA microheterogeneity. More interestingly, the high resolution provided by the analytical platform allowed the monitoring of novel oxidative products of HSA never reported before.

Download full article

Full view

Karla Mayolo-Deloisa, Jose Gonzalez-Valdez, and Marco Rito-Palomares
Biotechnol. Prog., 2016, Vol. 00, No. 00

Protein hydrophobicity can be modified after a PEGylation process. However, hydrophobic interaction chromatography (HIC) has been used to separate PEGylation reaction products less frequently than other techniques. In this context, chromatographic monoliths represent a good alternative to continue exploring the separation of PEGylated proteins with HIC. In this work, the separation of PEGylated proteins using C4 A monolith as well as Toyopearl Butyl 650C and Butyl Sepharose was analyzed. Three proteins were used as models: RNase A, b-lactoglobulin, and lysozyme. All proteins were PEGylated in the Nterminal amino groups with 20 kDa methoxy poly(ethylene glycol) propionaldehyde. The concentration of ammonium sulfate (1 M) used was the same for all stationary phases. The results obtained demonstrated that the C4 A monolith could better resolve all protein PEGylation reaction mixtures, since the peaks of mono- and di-PEGylated proteins can be clearly distinguished in the chromatographic profiles. On the contrary, while using Butyl Sepharose media only the PEGylation reaction mixtures of RNase A could be partially separated at 35 and 45 CVs. PEGylated proteins of b-lactoglobulin and lysozyme could not be resolved when Toyopearl Butyl 650C and Butyl Sepharose were used. It is then clear that monoliths are an excellent choice to explore the purification process of PEGylated proteins exploiting the advantages of HIC.

Download full article

Full view

Tarasova, I. A., Lobas, A. A., Černigoj, U., Solovyeva, E. M., Mahlberg, B., Ivanov, M. V., Panić-Janković, T., Nagy, Z., Pridatchenko, M. L., Pungor, A., Nemec, B., Vidič, U., Gašperšič, J., Krajnc, N. L., Vidič, J., Gorshkov, M. V. and Mitulović, G. ELECTROPHORESIS. Accepted Author Manuscript. doi:10.1002/elps.201500489.

Affinity depletion of abundant proteins such as human serum albumin (HSA) is an important stage in routine sample preparation prior to tandem mass spectrometry (MS/MS) analysis of biological samples with high range of concentrations. Due to the charge competition effects in electrospray ion source that results in discrimination of the low-abundance species, as well as limited dynamic range of MS/MS, restricted typically by three orders of magnitude, the identification of low-abundance proteins becomes a challenge unless the sample is depleted from high concentration compounds. This dictates a need for developing efficient separation technologies allowing fast and automated protein depletion. In this study we performed evaluation of a novel immunoaffinity-based CIMac depletion column with specificity to HSA (CIMac-αHSA). Because of the convective flow-through channels, the polymethacrylate CIMac monoliths afford flow rate-independent binding capacity and resolution that results in relatively short analysis time compared with traditional chromatographic supports. Seppro IgY14 depletion kit was used as a benchmark to control the results of depletion. Bottom-up proteomic approach followed by label-free quantitation using normalized spectral indexes were employed for protein quantification in G1/G2 and Cleavage/Blastocyst IVF culture media widely utilized in clinics for embryo growth in vitro. The results revealed approximately equal HSA level of 100% ± 25% in albumin-enriched fractions relative to the non-depleted samples for both CIMac-αHSA column and Seppro kit. In the albumin-free fractions concentrated 5.5-fold by volume, serum albumin was identified at the levels of 5 to 30% and 20 to 30% for the CIMac-αHSA and Seppro IgY14 spin columns, respectively.

Download full article

Full view