  • Can IVT yields be increased beyond 5-8 g/L?
  • Does feeding nucleotides into the IVT reaction increase its yield?
  • Is there a fast analytical method to quantify NTPs in IVT in real-time?
  • Can production of mRNA be automated?
Transitioning from batch to fed-batch IVT can increase IVT yield to 12 g/L resulting in 50 % reduction in cost per gram of mRNA. Integrating HPLC monitoring of IVT reaction can allow real-time decisions on feed additions.

Janja Skok, Polona Megušar, Tina Vodopivec, Domen Pregeljc, Nina Mencin, Matevž Korenč, Andreja Krušič, Anže Martinčič Celjar, Nejc Pavlin, Jana Krušič, Matthias Mueller, Kevin McHugh, Aleš Štrancar, and Rok Sekirnik

Chemie Ingenieur Techik, October 2022

The COVID-19 pandemic triggered an unprecedented surge in development of mRNA-based vaccines. Despite the need to increase process productivity and thus decrease the cost of mRNA vaccines, limited scientific literature is available on strategies to increase the yield of in vitro transcription (IVT) reaction, the unit operation with highest cost of goods, which has traditionally been performed as a batch reaction. Single-use bioreactors are traditionally used for cell-based production of biopharmaceuticals, but some core functionalities, such as controlled and automated feed addition, are potentially useful for cell-free mRNA processes. We report the production of 2 g mRNA in an Ambr® 250 Modular bioreactor system with a starting volume of 100 mL, reaching a maximum mRNA concentration of 12 g L−1 by a fed-batch IVT approach, and demonstrate the feasibility of continuous fed-batch production, paving the way towards continuous manufacturing of mRNA.

Download full article

Full view

Ana Ferjančič Budihna, Nejc Pavlin, Anže Martinčič Celjar, Andreja Gramc Livk and Aleš Štrancar

BioProcess International eBook, September 14, 2022

Robust and precise chromatographic analytical methods are key for the efficient development of the mRNA production process.

Three different analytical methods, which utilize three different column chemistries, are embedded in a ready-to-use PATfix™ analytical platform to support mRNA process development and product quantification and characterization.

Download full article

Full view

Tingting Cui, Kareem Fakhfakh, Hannah Turney, Gülin Güler-Gane, Aleksandra Toloczko, Martyn Hulley, Richard Turner

American Institute of Chemical Engineers, September 2022

In recent years, mRNA-based therapeutics have been a fast-growing new class of biologics that can, in principle, encode any protein(s) directly in patients to treat various diseases. mRNA vaccines have been proven to work efficiently, have high potency, and can be rapidly developed and deployed, which is critical for a quick responses in the case of a pandemic. Such agile development is enabled by rapid synthesis of RNA in vitro using recombinant enzymes rather than relying on lengthy and complex cell culture processes. mRNA exhibits physical and chemical properties differing from protein-based therapeutics. It is highly negatively charged and the hydroxyl group makes mRNA less stable and more susceptible to hydrolysis and nucleophilic cleavage. This novel work shares comprehensive studies carried out to compare the performance of various mRNA purification strategies by considering its scalability and critical quality attributes. In addition, the paper provides insights on how to establish a scalable mRNA purification process that consists of ultrafiltration/diafiltration and chromatography steps with good recoveries. Alternative Oligo(dT) based columns were further explored aiming to improve total process recovery. With Oligo(dT) as a capture step, overall recoveries of 70% can be achieved for mRNAs studied here that encode anti-influenza immunoglobulin G monoclonal antibodies.

Download full article

Full view

Katarina Markovič, Maja Cemazar, Gregor Sersa, Radmila Milačič and Janez Sčančar

Journal of Analytical Atomic Spectrometry

Ceruloplasmin (Cp) is the major copper-carrying (Cu) protein in human plasma. Due to copper's important physiological functions and its role in various diseases, there is a need to quantify the concentration bound to Cp and the exchangeable form of Cu. In the present work, conjoint liquid chromatography (CLC) on short-bed convective interaction media (CIM) monolithic disks was used to separate the Cu bound to low molecular mass (LMM) species, and the Cu bound to Cp and albumin (HSA) in human serum. Two immunoaffinity CIMmic albumin depletion (α-HSA) disks and one CIMmic weak anion-exchange diethylaminoethyl (DEAE) disk were assembled in a single housing, forming a CLC monolithic column. By applying isocratic elution with a 50 mmol L−1 MOPS buffer (pH 7.4) in the first 3 min, followed by gradient elution with 1 mol L−1 NH4Cl (pH 7.4) in the next 9 min, HSA was retained by the α-HSA disk, allowing subsequent separation of the LMM-Cu from the Cu bound to the Cp on the DEAE disk. Further elutio with 0.5 mol L−1 acetic acid in the next 4 min rinsed the HSA from the α-HSA disk. The separated Cu species were quantified by post column isotope dilution inductively coupled plasma mass spectrometry (ID-ICP-MS), while the elution profile of the proteins was followed by UV detection at 278 nm. Quantitative column recoveries were obtained. Good repeatability of the measurement was achieved for Cu-Cp (±1%), while for Cu-HSA and Cu-LMM species the repeatability of the measurements was slightly worse, due to the much lower Cu concentrations (±6% and ±9%, respectively). The developed method required only 20 μL of a 15-times diluted sample. Low limits of detection for the Cu-Cp, Cu-HSA and Cu-LMM species (6.1, 5.3 and 3.3 ng mL−1 Cu, respectively) were obtained. The technique was successfully applied in the determination of Cu-Cp, Cu-HSA and a fraction that most probably corresponds to the Cu-LMM species in the human serum of healthy individuals, kidney transplant patients and cancer patients.

Download full article

Full view

Nina Mencin, Andreja Krušic, Jure Ličen, Sebastijan Peljhan, Jana Vidič, Urh Černigoj, Tomas Kostelec, Aleš Štrancar and Rok Sekirnik

BioProcess International's Special Report, June 2022

Abstract:

Messenger RNA (mRNA) emerged as a powerful therapeutic tool for treatments in gene therapy, oncology, and infectious diseases, as recently demonstrated by vaccines against Covid-19. mRNA is produced by an enzymatic reaction that can be rapidly designed and scaled-up, and the platform is highly adaptable to different targets. One of the greatest challenges in mRNA production is the removal of process-related impurities stemming from in vitro transcription (IVT) reaction, such as residual nucleotide triphosphates, DNA template, enzymes, abortive transcripts.

Affinity-based chromatographic isolation of mRNA is robust and simple, lending itself as a useful industrial platform. mRNA constructs typically contain a 3’ polyA tail to increase stability in vivo, thereby enabling affinity purification using oligo-deoxythymidinic acid (Oligo dT) probes covalently coupled to a solid support. Macro-porous polymethacrylate monoliths offer high binding capacity and resolution for mRNA due to the convective nature of interconnected flow-through channels (>1.5 μm) modified with ligands that are easily accessible for mRNA. Typical binding capacity for CIMmultus™ Oligo dT for mRNA is 2-4 mg/mL, depending on construct length and loading concentration of NaCl.

Due to an increasing productivity of IVT reaction protocols, which routinely reach 5-10 mg/mL, elucidation of conditions that increase binding capacity of Oligo dT has been an intense focus of development. CIM® Oligo dT 0.05 mL Monolithic 96-well Plates were used for multi-parallel screening of binding conditions. Binding capacity could be significantly increased if NaCl is replaced with Gu-HCl, with DBC values of >6 mg/mL demonstrated, and scalability of binding capacity shown on CIMmultusTM Oligo dT preparative scale, which spans bed volume range 1 mL – 40 L, thereby theoretically supporting the purification of >200 g mRNA in a single run.

Read full article

Full view

2021
  • At which scale should chromatographic purification be introduced?
  • Are there analytical chromatography solutions to improve my process?
  • How to control dsRNA contamination in drug substance?
This paper is an overview of the use of chromatography in the complete production of mRNA, from plasmid to pure mRNA, including analytical HPLC.

Rok Sekirnik and Tomas Kostelec

BioProcess International's special report, December 2021

Abstract:

Rapid response to global pandemics requires the manufacture of billions of vaccine doses within months. This short timeline must allow for design and testing of active ingredients, development of production and purification processes, clinical evaluations, regulatory filings, and manufacturing. Existing purification methods often have been adopted from laboratory-scale techniques to allow rapid implementation, and those have provided adequate product quality. But future mRNA development will require optimized production and purification processes.

Chromatography has been a workhorse of biomanufacturing for decades, including for monoclonal antibodies, plasmid DNA, viruses, and other modalities — as well as for supporting analytics. As an emerging therapeutic modality, mRNA production requires the development of new methodologies to suit its peculiar physicochemical profile: large, charged, and relatively unstable. Due to requirements for high purity, these methodologies will be based in large part on chromatography.

This article describes the versatility of chromatography when applied to mRNA production, starting with the purification of the key raw material (plasmid DNA) to final polishing of mRNA drug substance.

Attachments

Full view

  • How does chromatography affect RNA stability?
  • Can HPLC be used for RNA stability assessment?
  • Is precipitation a good approach for small-scale RNA purification?
  • How do HPLC, bioanalyser, AGE, and other methods compare?
Thermal and freeze-thaw stability of a model RNA construct purified by various methods is evaluated by a range of analytical methods. Results indicate a stark contrast in stability, and discuss applicability of analytical methods for stability assessment.

Matevž Korenč, Nina Mencin, Jasmina Puc, Janja Skok, Kristina Šprinzar Nemec, Anže Martinčič Celjar, Pete Gagnon, Aleš Štrancar, Rok Sekirnik

Cell & Gene Therapy Insights 2021; 7(9), 1207–1216

Abstract:

One of the major challenges of mRNA based vaccines has been their requirement for distribution and storage at extremely low temperatures, indicating that exposure of mRNA to suboptimal physico-chemical conditions can result in degradation and loss of potency; it is unclear whether this is due to instability of mRNA drug substance, or LNP-encapsulated mRNA, or both. In this study we compare the stability of model mRNA drug substance (eGFP, 995 nt) prepared by affinity chromatography with the stability of mRNA purified by precipitation. We show that both purification methods lead to highly pure mRNA drug substance, however, mRNA purified by chromatography remains stable for 28 days at 37°C, whereas mRNA purified by precipitation is subject to significant degradation under the same storage conditions. We conclude that chromatography eliminates elements and/or conditions with adverse impact on the quality of mRNA to a greater extent than precipitation method and that choosing appropriate purification strategy is crucial not only to achieve target purity but also to obtain a stable product with retained integrity.

Read full article.

Full view

by Nejc Pavlin, Blaž Bakalar, Janja Skok, Špela Kralj, Andreja Gramc Livk, and Aleš Štrancar

BioProcess International, October 2021

Abstract:

Plasmid DNA (pDNA) has become a crucial component in the production of next generation therapeutics such as messenger RNA (mRNA) and viral vectors.

As companies ramp up their production capabilities and move towards clinical applications, obtaining cGMP grade pDNA has become a production bottleneck, leading to lengthy production delays.

There is a growing market demand for solutions that can streamline the production of cGMP pDNA and help optimize down-stream processes (DSP) for better yields & purity.

The key step in this process is having quantifiably reliable analytics that give rapid results
for process optimization and scale-up, as well as production runs.

Establishing and expanding inhouse pDNA production platform in a quick and efficient manner will be a key differentiator between more and less successful next generation therapeutics projects.

Download full eBook

Full view

Pete Gagnon, Blaž Goričar, Sara Drmota Prebil, Hana Jug, Maja Leskovec, Aleš Štrancar

BioProcess J, 2021; 20

Abstract:

Separation of empty and full AAV8 capsids was achieved during their elution from a weak anion exchanger with an ascending pH gradient at low conductivity. Experimental data suggest elution was mediated by loss of positive charge from the exchanger. The method produced a full capsid peak with fewer empty capsids than elution of a strong anion exchanger with a salt gradient. Elution of the weak exchanger by sodium chloride gradients or by pH gradients in the presence of sodium chloride gave inferior separation performance. Pre-elution of empty capsids with a pH step allowed full capsids to be eluted by salt without compromising separation. Loading at intermediate pH prevented empty capsid binding and enabled step elution of full capsids in a physiological buffer environment.

Read full article.

Full view

Nerea Zabaleta, Wenlong Dai, Urja Bhatt, Cécile Hérate, Pauline Maisonnasse, Jessica A. Chichester, Julio Sanmiguel, Reynette Estelien, Kristofer T. Michalson, Cheikh Diop, Dawid Maciorowski, Nathalie Dereuddre Bosquet, Mariangela Cavarelli, Anne-Sophie Gallouët, Thibaut Naninck, Nidhal Kahlaoui, Julien Lemaitre, Wenbin Qi, Elissa Hudspeth, Allison Cucalon, Cecilia D. Dyer, M. Betina Pampena, James J. Knox, Regina C. LaRocque, Richelle C. Charles, Dan Li, Maya Kim, Abigail Sheridan, Nadia Storm, Rebecca I. Johnson, Jared Feldman, Blake M. Hauser, Vanessa Contreras, Romain Marlin, Raphaël Ho Tsong Fang, Catherine Chapon, Sylvie van der Werf, Eric Zinn, Aisling Ryan, Dione T. Kobayashi, Ruchi Chauhan, Marion McGlynn, Edward T. Ryan, Aaron G. Schmidt, Brian Price, Anna Honko, Anthony Griffiths, Sam Yaghmour, Robert Hodge, Michael R. Betts, Mason W. Freeman, James M. Wilson, Roger Le Grand, Luk H. Vandenberghe

Cell Host & Microbe, Volume 29, Issue 9, 2021, Pages 1437-1453

Abstract:

The SARS-CoV-2 pandemic has affected more than 185 million people worldwide resulting in over 4 million deaths. To contain the pandemic, there is a continued need for safe vaccines that provide durable protection at low and scalable doses and can be deployed easily. Here, AAVCOVID-1, an adeno-associated viral (AAV), spike-gene-based vaccine candidate demonstrates potent immunogenicity in mouse and non-human primates following a single injection and confers complete protection from SARS-CoV-2 challenge in macaques. The AAVCOVID vector has no relevant pre-existing immunity in humans and does not elicit cross-reactivity to common AAVs used in gene therapy. Vector genome persistence and expression wanes following injection. The single low-dose requirement, high-yield manufacturability, and 1-month stability for storage at room temperature may make this technology well suited to support effective immunization campaigns for emerging pathogens on a global scale.

In this study, the AAVCOVID candidates were produced at larger scale via standard AAV production processes by Novartis Gene Therapies, following their stablished protocol with only minimal modifications to adjust to the AAVrh32.33 technology. Briefly, AC1 and AC3 were produced via three plasmid transfection. After cell lysis and lysate clarification, tangential flow filtration (TFF) was conducted to achieve volume reduction. The TFF retentate was next enriched for AAV particles on a cation exchange chromatography column (Sartorius BIA Separations). The eluate was concentrated, and buffer exchanged through an additional TFF step, before CsCl ultracentrifugation to separate genome containing versus empty AAV particles. Finally, formulation was achieved through TFF before bulk drug substance was filtered.

Read full article

Full view

Urh Černigoj, Jana Vidič, Ana Ferjančič, Urša Sinur, Klemen Božič, Nina Mencin, Anže Martinčič Celjar, Pete Gagnon, Aleš Štrancar

Electrophoresis, September 2021. https://doi.org/10.1002/elps.202100210

Abstract:

Elution of strong and weak anion exchangers with sodium chloride gradients is commonly employed for analysis of sample mixtures containing different isomers of plasmid DNA. Gradient elution of a weak anion exchanger (diethylaminoethyl, DEAE) in the presence of guanidine hydrochloride (Gdn) roughly doubles resolution between open-circular (oc) and supercoiled (sc) isomers. It also improves resolution among sc, linear, and multimeric/aggregated forms. Sharper elution peaks with less tailing increase sensitivity about 30%. However, elution with an exclusively-Gdn gradient to 900 mM causes more than 10% loss of plasmid. Elution with a sodium chloride gradient while maintaining Gdn at a level concentration of 300 mM achieves close to 100% recovery of sc plasmid while maintaining the separation improvements achieved by exclusively-Gdn elution. Corresponding improvements in separation performance are not observed on a strong (quaternary amine) anion exchanger. Other chaotropic salts do not produce a favorable result on either exchanger, nor does the inclusion of surfactants or EDTA. Selectivity of the DEAE-Gdn method is orthogonal to electrophoresis, but with better quantification than agarose electrophoresis, better quantitative accuracy than capillary electrophoresis, and resolution approaching capillary electrophoresis.

Read full article.

Full view

Rafael G. Ferreira, Neal F. Gordon, Rick Stock, Demetri Petrides

Processes 2021, 9(8), 1430

Abstract:

The COVID-19 pandemic has motivated the rapid development of numerous vaccines that have proven effective against SARS-CoV-2. Several of these successful vaccines are based on the adenoviral vector platform. The mass manufacturing of these vaccines poses great challenges, especially in the context of a pandemic where extremely large quantities must be produced quickly at an affordable cost. In this work, two baseline processes for the production of a COVID-19 adenoviral vector vaccine, B1 and P1, were designed, simulated and economically evaluated with the aid of the software SuperPro Designer.

In the purification process the retentate from the ultrafiltration step was subjected to anion-exchange chromatography (AEX), operating in capture mode, to remove protein and DNA impurities. A strong anion-exchange column with a monolithic structure (CIMmultus QA from Sartorius BIA Separations) is used in this step due to its high binding capacity for VPs.

Both processes were sized to produce 400 M/yr vaccine doses. The media and facility-dependent expenses were found to be the main contributors to the operating cost. The results indicate that adenoviral vector vaccines can be practically manufactured at large scale and low cost.

Read full article.

Full view

Tomas Kostelec, Rok Sekirnik, Anže Martinčič Celjar, Kristina Šprinzar Nemec, Andreja Gramc Livk, Pete Gagnon, Aleš Štrancar

BioProcess International, June 2021

Abstract:

COVID-19 has focused a spotlight on the ability of mRNA technology to accelerate vaccine development and approval. That same technology can hasten development and approval of other therapeutic classes, including cancer immunotherapy, protein replacement, and gene therapy. Fulfilling those opportunities imposes significant challenges on process developers and manufacturers to improve existing processes. Scale-up to produce millions of doses (tens of kilograms) compounds those challenges. Furthermore, every step of the journey requires high-performance analytical methods, to ensure patient safety and maximize productivity.

Read full article

Full view

Pete Gagnon, Maja Leskovec, Sara Drmota Prebil, Rok Žigon, Maja Štokelj, Andrej Raspor, Sebastijan Peljhan, Ales Štrancar

Journal of Chromatography A, 2021

Abstract:

Separation of empty and full adeno-associated virus capsids by multimodal metal affinity chromatography was investigated using a positively charged metal affinity ligand. A subpopulation of empty capsids eluted first, followed by full capsids, and later by more empty capsids and debris. Empty and full capsid composition of chromatography fractions was evaluated by cesium chloride density gradient centrifugation followed by stratigraphic flow analysis of the centrifuge tube contents, monitored by intrinsic fluorescence. Columns charged with barium, calcium, magnesium, zinc, manganese, and ferric ions gave similar results with respect to capsid separation. Charging with cupric ions maintained resolution between early-eluting empty capsids and full capsids but caused them to elute at lower conductivity. Empty and full capsids were fractionated with Tris-borate gradients, sodium chloride gradients, and magnesium chloride gradients. Recovery of full serotype 9 capsids was 100% with complete elimination of empty capsids. All metal ions bound contaminant subsets that required sodium hydroxide for removal. Columns charged with ferric iron and manganese bound more contaminants than all other metals. Columns charged with calcium, magnesium, barium, and copper bound the least. Contaminant binding on zinc-charged columns was intermediate between the two groups.

Download full article

Full view

Artaches A. Kazarian, Wesley Barnhart, Iain D.G. Campuzano, Jeremy Cabrera, Theodore Fitch, Jason Long, Kelvin Sham, Bin Wu, Justin K. Murray

Journal of Chromatography A,Volume 1634, 2020

Abstract:

The current study investigates a method for purification of the G-quadruplex secondary structure, naturally formed by a guanine-rich 21-mer oligonucleotide strand using a monolithic convective interaction media quaternary amine (CIM-QA) column under ion-exchange conditions. The monolithic support was initially evaluated on a preparative scale against a highly efficient TSKgel SuperQ-5PW ion-exchange support designed for oligonucleotide purification. The CIM analogue demonstrated clear advantages over the particle based support on the basis of rapid separation times, while also affording high purity of the G-quadruplex. Various parameters were investigated including the type of mobile phase anion, cation, pH and injection load to induce and control quadruplex formation, as well as enhance chromatographic separation and final purity. Potassium afforded the most prominent quadruplex formation, yet sodium allowed for the highest resolution and purity to be achieved with a 30 mg injection on an 8 ml CIM-QA monolithic column. This method was applied to purify in excess of 300 mg of the quadruplex, with excellent retention time precision of under 1% RSD. Native mass spectrometry was utilized to confirm the identity of the intact G-quadruplex under non denaturing conditions, while ion-pairing reversed-phase methods confirmed the presence of the single stranded oligonucleotide in high purity (92%) under denaturing conditions.

The key advantage of the purification method enables isolation of the G-quadruplex in its native state on a milli-gram scale, allowing structural characterization to further our knowledge of its role and function. The G-quadruplex can also be subsequently denaturated at elevated temperature causing single strand formation if additional reactions are to be pursued, such as annealing to form a duplex, and evaluation in in vitro or in vivo studies.

Download full article.

Full view

Michael Winkler, Mikhail Goldfarb, Shaojie Weng, Jeff Smith, Susan Wexelblat, John Li, Alejandro Becerra, Sandra Bezemer, Kevin Sleijpen, Aleš Štrancar, Sara Primec, Romina Zabar, April Schubert, Akunna Iheanacho, and David Cetlin

BioProcess International, April 2021

Abstract

Over the past decade, adenoassociated virus (AAV) vectors have become established as leading gene-delivery vehicles. In 2017, the pipeline for gene therapies included 351 drugs in clinical trials and 316 in preclinical development. As those candidates advance, significant efforts are being made in process development and manufacturing for viral vectors, with the overall goal of reducing process impurities while maintaining the highest possible process yield.

Sartorius BIA Separations has developed and commercialized CIMmultus QA monoliths, which have been cited in several AAV downstream processes for their ability to separate empty and full virus particles effectively. Monolithic supports represent a unique type of stationary phase for liquid chromatography, bioconversion, and solid-phase synthesis. Aside from increased processing speed, monolithic flow-through pores (channels) also provide easy access for large molecules, which supports both purification and depletion of nanoparticles such as plasmid DNA (pDNA) molecules and AAV particles.

Read full article

Full view

Thanaporn Liangsupree, Evgen Multia, Marja-Liisa Riekkola

Journal of Chromatography A, Volume 1636, 2021

Abstract

Extracellular vesicles (EVs) are heterogenous membrane-bound vesicles released from various origins. EVs play a crucial role in cellular communication and mediate several physiological and pathological processes, highlighting their potential therapeutic and diagnostic applications. Due to the rapid increase in interests and needs to elucidate EV properties and functions, numerous isolation and separation approaches for EVs have been developed to overcome limitations of conventional techniques, such as ultracentrifugation. This review focuses on recently emerging and modern EV isolation and separation tech- niques, including size-, charge-, and affinity-based techniques while excluding ultracentrifugation and precipitation-based techniques due to their multiple limitations. The advantages and drawbacks of each technique are discussed together with insights into their applications. Emerging approaches all share sim- ilar features in terms of being time-effective, easy-to-operate, and capable of providing EVs with suitable and desirable purity and integrity for applications of interest. Combination and hyphenation of techniques have been used for EV isolation and separation to yield EVs with the best quality. The most recent de- velopment using an automated on-line system including selective affinity-based trapping unit and asym- metrical flow field flow fractionation allows reliable isolation and fractionation of EV subpopulations from human plasma.

Attachments

Full view

Sebastijan Peljhan, Maja Štokelj, Sara Drmota Prebil, Pete Gagnon and Aleš Štrancar

Cell & Gene Therapy Insights, March 2021

Abstract:

Ultracentrifugation (UC) is a well-known technique for fractionating adeno-associated virus (AAV) capsids according to their density, which is mainly a function of their encapsidated DNA mass. Empty capsids represent the lowest density subpopulation. Full capsids represent the highest density subpopulation, sometimes accompanied by partially full capsids of intermediate density. Fractions can be collected after sedimentation for analysis but the practice is laborious and discourages application of multiple monitoring techniques that might provide deeper insights into sample composition. Anion exchange chromatography (AEC) also achieves fractionation of empty and full capsids for many AAV serotypes. The degree of separation varies among serotypes and does not correlate strictly with UC. This is not surprising since separation by AEC is highly influenced by capsid surface charge, which is independent of the amount of DNA packaged within the capsids. Chromatography methods however present a significant analytical advantage in the ease of monitoring the column effluent, including with multiple detectors. UV absorbance at 260 nm and 280 nm permits estimation of empty and full capsid proportions in any given peak. Intrinsic fluorescence enables estimation of relative areas of empty capsid peaks and full capsid peaks. Light scattering does the same and permits the further determination of capsid size and mass. In this report, we merge UC with an HPLC monitoring array to simultaneously analyze dual wavelength UV, intrinsic fluorescence, and light scattering through cesium chloride density gradient strata. Limitations of each monitoring method are discussed. UC results are compared with chromatography profiles to highlight distinction between separation methods. Practical application of results for final product characterization is considered, along with potential to support development of better purification processes.

Attachments

Full view

Pete Gagnon, Maja Leskovec, Blaz Goricar, and Aleš Štrancar

BPI, December 17, 2020

Abstract:

With its first licensed therapeutic now marketed worldwide, adeno-associated virus (AAV) has become a preferred vector for gene therapy. However, unlocking its full potential still poses challenges, many of which are associated with purification. The first involves the transition from upstream to downstream processes. AAV-bearing lysates are laden with debris that foul filtration media and limit or prevent concentration. Another challenge involves reduction of soluble host-cell DNA, which is complicated by its strong association with nucleoproteins. A third involves elimination of empty capsids. Currently, ultracentrifugation meets that need, but scale-up issues make chromatographic alternatives attractive. A fourth challenge involves the need for rapid, accurate, and revealing analytical results to guide process development, support validation, document control, and enable reproducibility of manufacturing processes. The following article shares experimental data showing how those challenges can be addressed to advance the evolution of gene therapy with AAV.

Attachments

Full view

Petrović T, Alves I, Bugada D, Pascual J, Vučković F, Skelin A, Gaifem J, Villar-Garcia J, Vicente MM, Fernandes Â, Dias AM, Kurolt IC, Markotić A, Primorac D, Soares A, Malheiro L, Trbojević-Akmačić I, Abreu M, Sarmento E Castro R, Bettinelli S, Callegaro A, Arosio M, Sangiorgio L, Lorini LF, Castells X, Horcajada JP, Pinho SS, Allegri M, Barrios C, Lauc G.

Glycobiology. 2020 Nov.

Abstract:

A large variation in the severity of disease symptoms is one of the key open questions in COVID-19 pandemics. The fact that only a small subset of people infected with SARS-CoV-2 develop severe disease suggests that there have to be some predisposing factors, but biomarkers that reliably predict disease severity have not been found so far. Since overactivation of the immune system is implicated in a severe form of COVID-19 and the IgG glycosylation is known to be involved in the regulation of different immune processes, we evaluated the association of inter-individual variation in IgG N-glycome composition with the severity of COVID-19. The analysis of 166 severe and 167 mild cases from hospitals in Spain, Italy and Portugal revealed statistically significant differences in the composition of the IgG N-glycome. The most notable difference was the decrease in bisecting Nacetylglucosamine (GlcNAc) in severe patients from all three cohorts. IgG galactosylation was also lower in severe cases in all cohorts, but the difference in galactosylation was not statistically significant after correction for multiple testing. To our knowledge, this is the first study exploring IgG N-glycome variability in COVID-19 severity.

Download full article

Full view