2012

There is an increasing demand for highly purified immunoglobulin G since they have found wide range of potential application in immunodiagnostics and immunotherapy.

Human IgG (hIgG) consists of four subclasses (IgG1, IgG2, IgG3 and IgG4) that show differences in some of their physicochemical characterictics and biological properties.

The present research project aims to separate subclasses of hIgG using monolithic stationary phase by SMB technology.

Attachments

Full view

2010

Analysis of a large number of samples requires chromatographic support that not only enables fast separation and purification of a target biomolecule from a complex matrix but also support an automation of a process. The methacrylate 96-well monolithic plate format enables both. 96-well monolithic plate reduces experimental time because it allows fast and efficient evaluation of parameters for binding and elution conditions. This format is a quicker alternative to several consecutive tests on chromatographic column.

Attachments

Full view

Protein L binds certain types of kappa light chains containing Fv and Fab fragments prepared from antibodies. In the case of IgG's the strong binding affinity refers only to human, mouse and rat species. It offers an advantage over Protein A and G as it binds to kappa light chains regardless of heavy chain subclass and can therefore binds up to 60% of IgG antibodies from human serum sample.

The main goal of our work was the preparation and characterization of CIM Protein L disks. First, Protein L disks with different densities of Protein L on the support were prepared in order to define the dependance of the IgG capacity on the amount of the bound Protein L. Further on, the method of characterization of Protein L disk using IgG was developed. In the end, the stability of the developed CIM Protein L disks in different solutions was tested in order to define the operating and storage conditions.

Attachments

Full view

In recent decades much work has been done on the development and optimisation of chromatographic supports in order to achieve efficient purification of biomolecules.

In the presented study we have investigated hydrodynamic and chromatographic properties of weak anion-exchange grafted monoliths (DEAE). Varying the concentration of the grafted polymer, grafted monoliths with different layer thickness and degree of branching were obtained. This results in a different hydrodynamic and chromatographic behavior of the examined monoliths such as permeability, ionic capacity and dynamic binding capacity (DBC) for the BSA protein. The DBC increases with the grafted layer thickness probably due to higher number of binding sites available for binding of the macromolecules. However, longer chains contribute to the reduction of the pore volume which results in a higher pressure drop. The latter can be additionally increased when biomolecules of interest are bound to the matrix. From this data information about the penetration depth into the grafted layer can be obtained giving an insight into the binding mechanism. Since the flow-unaffected properties were preserved even for large biomolecules, grafted monoliths may become a resin of choice for downstream processing of various macromolecules.

Attachments

Full view

CIMac™ Analytical Columns are high-performance monolithic columns offering all the advantages of a special continuous short polymeric bed and are primarily intended for fast, efficient and reproducible separations of biomolecules like large proteins – antibodies (IgG, IgM), plasmid DNA, phages and viral particles. Their small volume and short column length allow the operation at high volumetric flow rates (from 1 to 30 column volumes/min) thus enabling receiving the information about the product quantity and purity in just a few minutes. These columns are pre-packed in dedicated stainless steel housings and allow user friendly connections to HPLC equipment. The product family offers strong cation exchange, strong and weak anion exchange and specialty analytical column for plasmid DNA. All columns can be effectively used for the in-process and final control of various samples from different purification process steps.

Attachments

Full view

The biotechnological production of recombinants proteins consists of two main processes, upstream (biosynthesis) and downstream (protein purification) process. During the last decades the upstream process for mammalian cell culture has been improved significantly yielding in high amounts of protein. This development however led to a new challenge : the downstream process became a bottle-neck because of the large amounts of protein per batch in combination with the protein specific behaviors at high concentration.

In protein purification preparative chromatography is synonymous to “column chromatography”, and the favorable statics of a column are out of question for the physical requirements of beaded matrices. However, when approaching larger scales the physical dimensions of chromatography columns turn unfavorable: shallow gel beds of wide diameters. The footprint of such device increases drastically as does the weight, consequently resulting in limitations regarding floor space and floor bearing force.

A suitable chromatographic base matrix that is not obliged to a distinctive column design is a single piece of polymer – a monolith. Leaving the conventional column design, we have constructed a device for a monolith of rectangular shape, with the size of the monolith only limited by total weight (e.g. for handling and / or transportation). Using this design in a modular way, the individual modules can be stacked to make use of the height of a room at a very low footprint. A specific distribution system for feeding the monolith modules has been designed to allow a true linear scale-up from laboratory to large technical scale.

Attachments

Full view

2009

Bacteriophages were in recent years identified as a useful potential tool for different biotechnological applications such as alternative to antibiotics, detection of pathogenic bacteria, delivery vehicles for protein and DNA vaccines and as gene therapy delivery vehicles (1). For all listed fields of use it is important that phages are highly purified with preserved biological activity. Phage and other virus purification have traditionally been carried out by CsCl density gradient ultracentrifugation, which is however difficult to be scaled-up. An alternative is chromatography already proved to be efficient for purification and concentration of certain virus types.

One of the key issues using chromatography is processing time and capacity of the resin. Novel type of chromatographic resin named monoliths was already proved to be very efficient for fast separation and purification of macromolecules as are large proteins, DNA and viruses (2,3,4).

Our aim was to investigate whether Convective Interaction Media (CIM) methacrylate monolithic columns can be implemented for purification and concentration of phage T4 (virus for E.coli). Chromatographic method using linear gradient was implemented to investigate conditions for phage elution and to establish the optimized chromatographic method applying step gradient. We analyzed phage recovery and purity together with method reproducibility.

Attachments

Full view

2007

A number of IgM monoclonal antibodies are currently in development for treatment of autoimmune disease, infectious disease, and cancer. Growing interest in these molecules has created a need for an accurate, rapid, simple analytical method to measure IgM levels in cell culture supernatants, and to document the distribution of IgM and protein contaminants in chromatography fractions. High performance protein A columns are used for this application with IgG monoclonals, but IgMs are easily denatured by the harsh conditions required for elution of most affinity ligands. However, IgM monoclonals often exhibit strong retention on either cation exchangers, or anion exchangers, or both, making ion exchange chromatography a potential candidate for this application.

The large size of IgMs makes them a major challenge to particle-based chromatography media. Pentameric IgM has a mass of about 0.96 Md, and hexameric IgM about 1.15 Md. Their diffusion constants are about 2.5 x10-7 cm2/sec, about twice as slow as IgG. Since particle-based chromatography media mostly rely on diffusion for mass transport, both resolution and capacity are im- Figure 4 illustrates a modified anion exchange gradient configuration for monitoring the amount of IgM expressed in cell culture supernatants. A wash step was introduced to better remove con- paired, and increasingly so at higher flow rates.

Monolithic ion exchangers are characterized by an interconnected system of channels with diameters ranging 0.5 to 2.0 microns. This pore architecture supports convective flow, which conserves high resolution at high flow rates.[1] The lack of a void volume removes the major source of dispersion in chromatographic systems. This contributes to sharper peaks, which improves both resolution and sensitivity. Capacity is also conserved at high flow rates. This permits use of a microcolumn format that minimizes assay time and buffer consumption. This combination of features should make monoliths effective analytical tools for IgM.

Attachments

Full view

Membrane based anion exchangers are being used increasingly for purification of monoclonal antibodies. The transition from particle-based anion exchangers is driven partly by the convenience of membranes and partly by the cost saving associated with their disposability, however the feature that makes them functionally superior is more effective mass transport.

Attachments

Full view

IgM can be used for several purposes such as early detection of certain diseases or, when labelled, localized cancer tumours. For their purification commonly chromatography is used. Methods for purifying such big molecules (M.w. around 950 kDa) are usually long and time consuming since these molecules have extremely low mobility therefore mass transfer between mobile and stationary phases is significantly reduced. When purified using affinity mode, serious decrease in IgM activity can occur because of long exposure to low pH in which they are unstable. Furthermore, because of their size, the IgM capacity of convenctional resins is rather low. CIM monoliths were already successfully used for fast separation of large molecules. In this work we tested applicability of anion-exchange CIM monolithic columns for preparation of IgM.

Attachments

Full view

2006

Commercially available CIM® disk monolithic columns are intended for very fast analyzes and laboratory purification. Their shape is a compromise to achieve acceptable resolution and binding capacity what make them suitable for wide range of laboratory applications. Separations of complex protein mixtures can be carried out within just a few seconds because of flow unaffected resolution and, on the other hand, purification can be effectuated with high productivity due to flow-unaffected dynamic binding capacity [1]. However, in many cases in the field of molecular biology, only a limited amount of sample is available. In such a case it is beneficial to work with small columns having high resolution or they can be used as affinity columns or bioreactors saving significant amount of valuable ligand. Having this goal in mind we developed CIM® disks with the volume of 1/10th and 1/100th of original volume. In comparison to conventional CIM® disks, they exhibit higher resolution and lower limit of detection, therefore smaller concentrations of target macromolecules can be detected. The separation ability and the protein capacity were tested on anion and cation exchange 3.4 mL and 34m L mini disk monolithic columns.

Attachments

Full view

Analysis of a large numbers of samples requires chromatographic supports that not only enable fast separation and purification of a target biomolecules from a complex matrix but are also involved in an automation process. The 96 – microtiter plate format enables both. Although they are routinely used for decade's only recently few reports about the microtiter plates bearing monoliths as a separation media, were reported [1]. Because of advantageous properties such as flow unaffected dynamic binding capacity and resolution 96 - microtiter plates with methacrylate based monolith were prepared. Characterisation of such plate demonstrated that uniform flow rate can be achieved through all wells and no leakage is present. Efficient separation of proteins was achieved within minute. Furthermore CLC (Conjoined Liquid Chromatography) concept [2] originally derived for analytical columns on CIM disk, can easily be extrapolated to microtiter plates. We demonstrated that multidimensional chromatography with 96 – well plate is feasible and can further accelerate screening processes.

Attachments

Full view

2005

The Inter-alpha inhibitor protein family is comprised of complex plasma proteins that consist of a combination of multiple polypeptide chains (light and heavy chains) covalently linked by a chondroitin sulfate chain. The major forms found in human plasma in high concentration are Inter-alpha inhibitor (Ial), which consists of two heavy chains (Hl & H2) and a single light chain, and Pre-alpha Inhibitor (Pal), which consists of one heavy (H3) and one light chain (Fig 1). The light chain (bikunin) is known to inhibit several serine proteases, such as trypsin, human leukocyte chistase, plasmin and cathepsin G which are involved in inflammation, sepsis, tumor invasion and formation of metastasis. Recently, a monoclonal antibody against human inter-alpha inhibitor proteins (MAli 6931) was developed in our laboratory.

Attachments

Full view

The analysis of molecular interactions is a key part of the drug discovery process, and analytical techniques are available for studying in vitro the ligand/target complex since the early stage of the drug development process.

With regard to the assessment of the activity of chemical libraries, the affinity chromatography on HPLC immobilized-enzyme column (or immobilized enzyme reactors, IMER) is one of most promising methodologies for HTS applications.

Human recombinant acetylcholinesterase (hAChE) represents a well-known target for drug-discovery in Alzheimer’s Disease.

Attachments

Full view

The rapidly growing interest in the area of proteomics induces intensive efforts to find robust, automated and sensitive high-throughput analytical tools. In this context, the concept of solid-phase digestion (ex. trypsin immobilization on a solid support[1]) has received great attention in the last years. Trypsin (EC 3.4.21.4) has been covalently immobilized on different monolithic supports and resulting bioreactors used as immobilized enzyme reactors (IMERs) for on-line digestion, peptide separation and peptide mapping. Bioreactors efficiencies were evaluated with different recombinant proteins after on-line digestion. The technique used for the separation and identification of peptides was high-performance liquid chromatography coupled with electrospray ionisation tandem mass spectrometry (LC-ESI-MS/MS).

Attachments

Full view

Immobilized Metal-Affinity Chromatography (IMAC) is a chromatographic separation technique primarily used for the purification of proteins with exposed histidine residues and for recombinant proteins with histidine tags. Technique uses covalently bound chelating compounds on chromatographic supports to entrap metal ions, such as Cu2+, Ni2+, Zn2+, Co2+, which serve as affinity ligands for various proteins. CIM Convective Interaction Media is a monolithic chromatographic support intended for separation of large biomolecules, such as proteins, DNA and also viruses.

Attachments

Full view

Immobilized Metal-Affinity Chromatography (IMAC) is a separation technique primarily intended for the purification of proteins with exposed histidine tags. Technique uses covalently bound chelating compounds on chromatographic supports to entrap metal ions, which serve as affinity ligands for various proteins. Iminodiacetic acid (IDA), nitrilotriacetic acid (NTA), carboxymethylated aspartic acid (CM-Asp), and N,N,N’-tris(carboximethyl) ethylenediamine (TED) are chelating compounds, most often used to entrap metal ions, such as Cu2+, Ni2+, Zn2+, Co2+ etc.

Convective Interaction Media CIM® is a monolithic support, which provides high rates of mass transfer at low pressure drops. It has been shown that CIM® supports are very efficient for the separation of large molecules, such as proteins and DNA (1). Recent publication has proved that CIM IMAC column can be used for separation of histidine containing peptides (2). Since efficient separation of large molecules is one of the main advantages of CIM® support, purification of His-tagged recombinant proteins on CIM IMAC column should be not only feasible but also simple, fast and efficient.

Attachments

Full view

Affinity chromatography is a key method for protein purification. Its main advantage is in the high specificity which enables purification of a single protein from complex biological mixtures. For practical use the specific ligand should be immobilised on insoluble matrix. As a matrix, standard chromatographic supports are commonly used. They are normally in form of small (some m in diameter) particles containing pores to provide high specific surface resulting in high binding capacity. The pores are normally closed on one side, thus the liquid inside them is stagnant and the molecules are transported to the active site by diffusion. Since the diffusion coefficients for macromolecules, such as proteins, are very low, diffusion determines the overall process dynamics. As a consequence, separation or purification of the proteins takes normally 0.5 to 1h even on analytical scale.

Attachments

Full view

A large number of diagnostics and several therapeutic monoclonal antibodies (mAbs) have been approved worldwide and many more are expected to be approved and licensed in the near future. The reality and the fact that purification or downstream processing can contribute up to 80% of the total production costs of a biopharmaceutical, enhance the need for efficient purification methods. Liquid chromatography provide high level of purity required for human use, increases productivity and has therfore become the method of choice for purification of biopharmaceuticals.

Purification of mAbs can be achieved by a number of chromatographic methods, Protein A and Protein G affinity chromatography being especially powerful enabling high product purity with single chromatographic step.

Attachments

Full view

Human plasma is a rich and readily accessible source for the detection of diagnostic markers and therapeutic targets for various human diseases. These are usually proteins that are present in human plasma in extremely low concentrations and are often masked by the high abundance proteins like immunoglobulin G (IgG) and human serum albumin (HSA), which represent over 75 % of all proteins. In order to enable the detection of potential biomarkers, IgG and HSA should be efficiently removed from the starting sample. In this work an affinity and a pseudoaffinity chromatographic column, used for an efficient removal of IgG and HSA from human plasma, were thoroughly characterized. A CIM monolithic column bearing Protein G ligands was
used for the removal of IgG, and a column bearing an anti-HSA dye was used for the depletion of HSA.

Attachments

Full view