2018

Immunoaffinity columns using antibodies as ligands against mammalian proteins could be used for different applications in protein expression control and, if a standard available, for direct protein quantification in complex sample solutions. Additionally, these columns are ideal for polishing step of recombinant proteins, such as mammalian receptor Fc fusion proteins. Most importantly, such columns could extract a significant amount of a single membrane protein from native source, suitable for downstream analyses, such as mass spec analysis of their glycans. Immunoaffinity chromatographic monoliths against RAE-1 GPI anchored glycoprotein were developed (CIMmic HDZ - @RAE-1 column) as a part of Glycomet project with the main goal to analyze the antigen glycoprofile.

Attachments

Full view

Hydrazide-activated (HDZ) columns were proven to be a product of choice for making the most effective immunoaffinity columns. They take advantage of a special hydrazide linkage that binds antibodies through the carbohydrate residues on their Fc regions. This leaves the antigen-binding domains fully accessible to enable the most effective capture of desired target (Figure bellow).
CIMac™ HDZ monoliths make HDZ-immobilized antibody columns even more effective. Because of their large channel size and the efficiency of convective mass transport, they eliminate the long loading residence times that are required for affinity chromatography on porous particle columns. Flow rates of 5–10 column volumes per minute allow complete purifications in a few minutes, even when the source material contains a low concentration of antigen. The same performance is achieved whether a small peptide or a large bio-assemblage like a virus particle or extracellular vesicle is isolated. The combination of HDZ monoliths and the immobilization protocol offers a strong tool for fast antigen isolation from complex biological sample (plasma, lysate, etc.) and consequently sensitive antigen quantification. An example of CIMac™ HDZ application is a purification of fibrinogen from human plasma.

Attachments

Full view

CIM® chromatographic monoliths enable high 1) productivity of pDNA downstream process (DSP) due to high dynamic binding capacity for pDNA in small elution volumes and short chromatographic runs; 2) high resolution power due to convective-based mass transfer.

Sample displacement mode utilizes different relative binding affinities of components in a sample mixture and separates pDNA isoforms under overloading conditions - where sc pDNA isoform acts as a displacer of oc or linear pDNA isoform.

Attachments

Full view

2017

Preparative scale chromatographic separation of open-circular (oc) from supercoiled (sc) plasmid DNA (pDNA) isoforms has been already established on CIM® C4 with high ligand density (C4 HLD) monolithic columns with sample loading in 3.0 M ammonium sulphate (AS). The process requires high molarity of AS, increasing the overall cost of the process. Sample displacement chromatography (SDC) can be used as an alternative to decrease the AS concentration required during loading onto hydrophobic chromatographic supports. This study compares three chromatographic monoliths with different hydrophobic ligands on the surface (C4 HLD, pyridine and histamine) for the purification of different pDNA vectors in SD mode.

Attachments

Full view

2016

The upstream and downstream monoclonal antibody (mAb) bioprocessing makes them susceptible to physical and chemical modifications. In the biotechnological production process of mAbs, structural variations may arise due to some enzymatic activity. Antibody charge variants have gained considerable attention in the biotechnology industry due to their potential influence on stability and biological activity and cation-exchange chromatography (CEX) is one of the typical approaches for mAb charge variant analyses. We tested several CEX columns under different conditions and the best column for isotype separation was weak cation-exchanging CIMac COOH chromatographic monolith in pH gradient. We have proven a flow independent separation of mAb charge variants and in this way, a resolution comparable to classical CEX particulate-based analytical columns was achieved in only 6 min analysis time.

Attachments

Full view

Since plasmid DNA (pDNA) as a pharmaceutical product has stringent requirements of purity and efficacy, one or more chromatographic steps are often used in the downstream processing train. High ligand density butyl-modified (C4 HLD) monolithic support is currently used in a polishing step of a pDNA purification process (1) and is mainly focused to supercoiled (sc) pDNA isoform separation from the open circular (oc) and linear pDNA isoform as well as for removal of remaining gDNA and RNA. The goal of the study was to compare the productivities of two variations of the polishing chromatographic process employing monoliths – classical bind-elute (BE) versus recently described (2) sample displacement purification (SDP). Classical purification requires high concentration of ammonium sulphate (AS) during loading step and elution is then achieved by descending AS gradient. SDP utilises different relative binding affinities of components in a sample mixture and separates pDNA isoforms under overloading conditions, where sc pDNA isoform acts as a displacer of oc or linear pDNA isoform.

Attachments

Full view

2015

CIMac™ r-Protein A Analytical Column is short bed, high performance monolithic column . Primarly is intended for fast, efficient, and reproducible qualitative and quantitative analyses of Immunoglobulin G (IgG). It is suitable for use with HPLC and UPLC systems. Quantification of Immunoglobulin G is possible between 0.2 μg and 20 μg. Its small volume and short column length allow operation at high volumetric flow rates ( up to 3mL/min). The information about product quantity and purity is thus generated in just 1 minute! The column has innovative symmetric design for bi-directional flow, also extending column lifetime.

Attachments

Full view

2014

Biological samples often consist of a main component, such as albumin in serum, and many other constituents, present in smaller quantities, but nevertheless of high importance in biological systems. When detection of the low-abundance molecules is needed, the main component could interfere with the analyte, complicating the analysis or even making it impossible. In such cases a possible approach is to remove the interfering main component from the sample before the analysis.

Monolithic columns (CIM®) are a great foundation to build affinity chromatography methods, as they offer fast flow rates and can be modified to accomodate various ligands. We selected two most promising approaches for oriented binding of antibodies to the monolithic support. One approach was to bind antibodies to a protein A (pA) column with consequent crosslinking of the protein complex. The other approach was to chemically activate antibodies and bind them selectively to hydrazide-modified (HDZ) monolith surface.

Attachments

Full view

One of the major requirements for pharmaceutical-grade pDNA is its high homogeneity, being mostly in supercoiled (sc) isoform. Chromatographic separation of sc pDNA from open coiled (oc) or linear isoform is challenging due to their similar interactions with the chromatographic phases. Promising separation efficiency of pDNA isoforms was proven on recently developed histamine modified monolithic chromatographic column in descending ammonium sulfate gradient. The aim of the study was to further optimise the chromatographic conditions for sample analysis, where all three isoforms would be baseline separated.

Attachments

Full view

Interactions between antibodies and their antigens are highly selective and therefore immensely popular for affinity chromatography. Consequently, numereous antibody immobilizations were performed on monolithic supports via different activation chemistries in the last decade. Despite the work already done there was no systematic study, where as many as possible activation chemistries were tested for the immobilization of a model monoclonal antibody with subsequent chromatographic characterization of the affinity support. In this work, various preactivated CIM monolithic columns were used for the immobilization of a model monoclonal IgG.

Attachments

Full view

Monolithic ion exchange CIM® (Convective Interaction Media) columns have been proven in quantitative analysis of different immunoglobulins such as IgM and IgG from human plasma or cell supernatants. The separation mechanism is based on ionic interactions between the ion exchange monolith and immunoglobulin that are controlled by salt concentration. Here we present another possibility of IgM determination based on monolithic CIM® OH columns where the interactions may be controlled by changes in salt concentration or by pH increase. A method for quantitative HPLC determination of IgM in cell supernatant with fluorimetric detection was developed on CIM® OH column (0.34 mL) by means of pH increase. Optimal separation of IgM from cell supernatant matrix was achieved by combining acetate and phosphate buffer in a suitable gradient profile. Two different quantification methods, i.e. calibration curve and standard addition.

Attachments

Full view

Enrichment of phosphopeptides prior to LC-MS analysis is a crucial sample preparation step because of their low stoichiometry in biological sample, longer retention on reversed phase columns, and lower ionization efficiency compared to non-phosphorylated peptides [1].The use of metal oxides, most prominently of TiO2 enabled efficient and relatively simple phosphopeptide-enrichment. In this study a new monolithic column from BIA Separations containing immobilized TiO2-nanoparticles was tested for its ability to enrich phosphopeptides. The TiO2-column was also tested for possible carryover originating from biological samples. In conclusion, tested monolithic TiO2 columns show significant binding ability for phosphopeptides and are considered as suitable for phosphopeptide enrichment.

Attachments

Full view

The demand for human immunoglobulin is invariably increasing on an annual basis. To satisfy demands, different manufacturing processes are used to isolate immunoglobulins from human plasma. A quest for alternative paths in manufacturing not only requires development of the most economical manufacturing process, but also a rapid method development and development of reliable analytics for manufacturing monitoring. For an efficient improvement of the purification methods as well as for in-process control during manufacturing stage, the usage of reliable and fast analytical techniques are of crucial importance.

Fast and reliable fingerprint-based method for characterization of immunoglobulin G (IgG) prepared from Cohn I+II+III paste in two chromatographic steps is presented. The fingerprint method bases on partial separation of proteins in linear gradient on CIMac QA 0.1 mL column. Partial separation of proteins does not allow simple quantitative analysis of the samples during the IgG production from Cohn I + II + III paste, however, a very accurate qualitative information about the composition of the sample can be obtained in less than 5 minutes.

Attachments

Full view

2013

The development of safe, effective, and affordable vaccines has become a global effort due to its vast impact on overall world health conditions. A brief overview of cancer vaccine characterization techniques, especially in the area of high-resolution mass spectrometry, is presented. It is highly conceivable that the proper use of advanced technologies such mass spectrometry, along with the appropriate chemical and physical property evaluations, will yield tremendous in-depth scientific understanding for the characterization of vaccines in various stages of the development. This work presents the physiochemical and biological characterization of two cancer vaccines: Racotumomab and Her1-ECD. Racotumomab monoclonal antibody is a murine anti-idiotypic antibody that mimics N-glycolyl-GM3 gangliosides. This antibody has been tested as an anti-idiotypic cancer vaccine, adjuvated in Al(OH)3, in several clinical trials for melanoma, breast, and lung cancer. The Her1-ECD is a vaccine preparation based on the extracellular domain of HER1 and it is being evaluated in Phase I clinical study in patients with refractory prostate cancer.

Attachments

Full view

2012

Monolith chromatography media coupled with metal affinity ligands proved superior to the conventional particle-based matrix as a plasmid DNA (pDNA) purification platform. By harnessing the differential affinity of pDNA, RNA. Host cell proteins and endotoxin to copper ions in the solution a majority of endotoxin (90%) was removed from the alkaline cell lysate using CuCl2-induced precipitation. RNA and remaining endotoxin were subsequently processed by copper immobilized metal affinity column employing either monolith or particle-based matrix where both RNA and endotoxin were removed below detection limit with almost complete recovery of pDNA in the monolith was found to have several advantages in terms of handling feedstocks crowded with RNA in a concentration-independent manner and exhibiting flowrate-independent dynamic binding capacity for RNA. This enabled monolith-based process to be conducted at high feed concentration and flow rate. Resulting in pDNA vaccine purification at a high yield and purity and the process conditions investigated, the use of monolith column gave at least three fold higher productivity for recovery of purified pDNA as compared to the particle- based column, demonstrating its potential as a more rapid and economical platform for pDNA vaccine purification.

Attachments

Full view

The present study describes a new methodology to quantify and monitor the quality of supercoiled (sc) plasmid DHA (pDLIA), using a monolithic column based on anion-exchange chromatography. This analytical method with UV detection allows distinguishing the plasmid isoforms by a NaCl stepwise gradient. The selectivity, Linearity, accuracy, reproducibility and repeatability of the method have been evaluated, and the lower quantification and detection limits were also established. The validation was performed according to the guidelines, being demonstrated that the method is precise and accurate for a sc plasmid concentration up to 200 µg/mL. The main advance achieved by using this monolithic method is the possibility to quantify the sc plasmid in a sample containing other plasmid topologies, in a 4 minutes experiment. This work also intends to evaluate the possibility to assess the sc pDNA present in more complex samples, allowing the control of the samples recovered from different bioprocess steps.

Attachments

Full view

Glycosylation is one of nature mechanism for invreasing the diversity of protein structures affecting biophysical vjaracterostocs and bioactivity. Glycoproteins exist as mixture of different isoforms ("glycoforms"). In this mixture a group od different glyco components is attached to individual glycosylation site. Different glyco componets attached to the same site may have diggerent effect on biophysical charachteristics of glycoproteins. The type of glycosylation and the degree of heterogenity are important for many reasons starting from stability, activity, clinical efficency (toxicity, pharmacokinetics, immunogenicity), to standardization and patentability.

Thus, it is necessary to separate glycoforms and as much as possible to difine the heterogenity i.e. population of of glyco components attached to the singele glycosysilation site.

External invertase is a widely usef model for studying the influance of the glyco-component on protein stability. External invertase from yeast Sccharomyces cerevisiae has 14 potential N-glycosylation sites in the sequence, 13 of which are fully or partially glycosylated with olygomannans of varying sizes.

Attachments

Full view

Extensive research in the last two decades has led to the realization of Immunoglobulin M (IgM) as a potential therapeutic and diagnostic agent for autoimmune diseases, infectious diseases and as an AIDS and cancer vaccine. Growing interest in these molecules has created a need for an accurate, rapid and simple analytical method to measure IgM concentrations during the production (in-process control) in cell culture supernatants as well as in all purification steps in the downstream processing.

Convective interaction media (CIM) monolithic columns has been increasingly recognized as a quantification tool for large molecules. Affinity ligands like protein A and protein G are the most common ligands used for antibody capture and analysis.

Attachments

Full view

There is an increasing demand for highly purified immunoglobulin G since they have found wide range of potential application in immunodiagnostics and immunotherapy.

Human IgG (hIgG) consists of four subclasses (IgG1, IgG2, IgG3 and IgG4) that show differences in some of their physicochemical characterictics and biological properties.

The present research project aims to separate subclasses of hIgG using monolithic stationary phase by SMB technology.

Attachments

Full view

2010

Application of plasmid DNA for gene therapy and vaccination has gained huge interest in last two decades. Topological homogeneity and impurity content are crucial for therapeutic usage of pDNA. Major influence on achieving regulatory demands in pDNA production has downstream processing and in order to get optimal purity different purification techniques have to be included. It was demonstrated that methacrylate monoliths can be used for efficient purification process of plasmid DNA. High dynamic binding capacities and high flow rates of methacrylate monolith enabled excelent purity and productivity.

Attachments

Full view