On May 12th, the biaseparations.com website will be retired and migrated tosartorius.com.Learn moreabout our combined offering today!
2010

In recent decades much work has been done on the development and optimisation of chromatographic supports in order to achieve efficient purification of biomolecules.

In the presented study we have investigated hydrodynamic and chromatographic properties of weak anion-exchange grafted monoliths (DEAE). Varying the concentration of the grafted polymer, grafted monoliths with different layer thickness and degree of branching were obtained. This results in a different hydrodynamic and chromatographic behavior of the examined monoliths such as permeability, ionic capacity and dynamic binding capacity (DBC) for the BSA protein. The DBC increases with the grafted layer thickness probably due to higher number of binding sites available for binding of the macromolecules. However, longer chains contribute to the reduction of the pore volume which results in a higher pressure drop. The latter can be additionally increased when biomolecules of interest are bound to the matrix. From this data information about the penetration depth into the grafted layer can be obtained giving an insight into the binding mechanism. Since the flow-unaffected properties were preserved even for large biomolecules, grafted monoliths may become a resin of choice for downstream processing of various macromolecules.

Attachments

Full view

CIMac™ Analytical Columns are high-performance monolithic columns offering all the advantages of a special continuous short polymeric bed and are primarily intended for fast, efficient and reproducible separations of biomolecules like large proteins – antibodies (IgG, IgM), plasmid DNA, phages and viral particles. Their small volume and short column length allow the operation at high volumetric flow rates (from 1 to 30 column volumes/min) thus enabling receiving the information about the product quantity and purity in just a few minutes. These columns are pre-packed in dedicated stainless steel housings and allow user friendly connections to HPLC equipment. The product family offers strong cation exchange, strong and weak anion exchange and specialty analytical column for plasmid DNA. All columns can be effectively used for the in-process and final control of various samples from different purification process steps.

Attachments

Full view

The biotechnological production of recombinants proteins consists of two main processes, upstream (biosynthesis) and downstream (protein purification) process. During the last decades the upstream process for mammalian cell culture has been improved significantly yielding in high amounts of protein. This development however led to a new challenge : the downstream process became a bottle-neck because of the large amounts of protein per batch in combination with the protein specific behaviors at high concentration.

In protein purification preparative chromatography is synonymous to “column chromatography”, and the favorable statics of a column are out of question for the physical requirements of beaded matrices. However, when approaching larger scales the physical dimensions of chromatography columns turn unfavorable: shallow gel beds of wide diameters. The footprint of such device increases drastically as does the weight, consequently resulting in limitations regarding floor space and floor bearing force.

A suitable chromatographic base matrix that is not obliged to a distinctive column design is a single piece of polymer – a monolith. Leaving the conventional column design, we have constructed a device for a monolith of rectangular shape, with the size of the monolith only limited by total weight (e.g. for handling and / or transportation). Using this design in a modular way, the individual modules can be stacked to make use of the height of a room at a very low footprint. A specific distribution system for feeding the monolith modules has been designed to allow a true linear scale-up from laboratory to large technical scale.

Attachments

Full view

2009

Adeno-associated virus (AAV) vectors continue to hold immense promise as gene transfer vehicles for a variety of gene therapy applications. Numerous pre-clinical and human clinical studies have been undertaken with rAAV, employing several of the identified serotypes to leverage their differing tissue tropism to correct a broad spectrum of genetic diseases. Despite the advantageous characteristics of rAAV and the extensive research into pre-clinical applications, production and purification scale-up continues to limit recombinant AAV (rAAV) use in large clinical trials that require even moderate vector doses. Therefore, AGTC has developed a high-yielding, scalable rAAV production system in suspension BHK cells that employs co-infection with two hybrid rHSV-rAAV vectors to provide all cis and trans-acting rAAV elements and the requisite helper virus functions for rAAV manufacturing.

In contrast to traditional, resin-based chromatography methods for rAAV purification, we have developed a two-step chromatographic process that employs a novel anion exchange Convective Interaction Media® monolithic column (CIM® monolith, BIA Separations) capture step followed by affinity chromatography (AVB Sepharose™, GE Healthcare), which yields rAAV vector stocks in very high purity. This scalable process allows significant reduction in processing time due to the high capture step dynamic binding capacity, flow rates and resolution. The resulting overall chromatography recovery compares favorably to our first and second generation processes which used three-step, resin-based column chromatography and membrane-based two step chromatography, respectively.

The CIM QA-AVB process was scaled to accommodate 10 L suspension production runs and was successful at recovering as much as 1 × 1015 purified AAV1 DRP in a single day. The process is highly reproducible and it is applicable for the purification of multiple AAV serotypes with over 95% purity and overall yield of > 30%.

Attachments

Full view

Avir Green Hills Biotechnology is developing innovative seasonal and pandemic influenza vaccines based on the deletion of the NS1 gene (delNS1 vaccine). The vaccine is replication-defective and applied intranasally. Currently, an H1N1 monovalent vaccine is being tested in a clinical phase I study, with an H5N1 avian influenza vaccine soon to be initiated. A production and purification process, which was successfully employed for the pilot-scale production of H1N1 and H5N1 influenza A vaccine virus, will be presented. Data on the selection of chromatographic media, relevant to eliminate downstream purification bottlenecks will also be discussed.

Details on obtained virus yields as well as impurity removal will be given. The vaccine virus is produced in static cell culture using Vero (African Green monkey kidney) cells. After clarification the vaccine virus bulk is purified using the same scheme for all different subtypes: Concentration by tangential ultra filtration, AEX chromatography using a CIM QA monolith, and an SEC polishing step allowing for buffer exchange. This purification scheme guarantees the thorough depletion of host cell DNA and total protein. In addition, an HPLC method for quantifying influenza virus in the vaccine with the use of CIM monolithic columns will be presented and the results will be compared with haemagglutination method.

Attachments

Full view

In an average influenza season, we face hundreds of thousands of influenza cases. Up to 50,000 deaths per year can be ascribed to influenza epidemics. Nevertheless, this is relatively harmless compared to the current, permanent threat of a worldwide pandemic caused by avian influenza.

AVIR Green Hills Biotechnology is developing innovative seasonal and pandemic influenza vaccines based on the deletion of the NS1 gene (ΔNS1 vaccine) [1]. The vaccine is replication-defective and applied intranasally. Currently, an H1N1 monovalent vaccine is being tested in a clinical phase I study and clinical trials with H5N1 avian influenza vaccine will follow in fall 2007.

A production process, which was successfully employed for the pilot-scale production of H1N1 and H5N1 influenza A virus is presented here. The upstream process is performed according to the specific requirements of the respective influenza subtypes. Currently, 15 L batches are produced in cell factories using Vero (African green monkey kidney) cells. The vaccine bulk is purified by using the very same scheme for all different subtypes. For purification, the cell culture supernatant is clarified by centrifugation and the virus is concentrated by tangential ultra filtration. The concentrated virus is subsequently purified in two chromatographic steps which were co-developed with BIA Separations d.o.o.: First, an anion exchange monolithic column is used. This is followed by size exclusion chromatography for polishing and buffer exchange.

This purification scheme guarantees the thorough depletion of host cell DNA and total protein, and recovers at least 25% of the infectious virus.

Attachments

Full view

2008

During last decades different methods for purification of influenza viruses have been described. Most of these methods were developed for purification of egg derived influenza virus which is still the main production system for influenza vaccine viruses. Since cell culture based technology is gaining more and more importance, the need for alternative, efficient and scaleable purification methods has risen. Chromatography is becoming a method of choice for purification of viruses. Relevance of this technique was recently demonstrated also for influenza viruses. Methacrylate monoliths are characterized by large channel diameter, high surface accessibility and convective mass transport. As a consequence they have high binding capacity for large molecules, enable high flow rates at low pressure drop and therefore increase productivity. Recently it has been proven that methacrylate monolithic columns can also be used for purification and concentration of different viruses.

It was the purpose of this work to explore possibilities for purification of influenza viruses on ion exchange methacrylate monoliths. Different subtypes of influenza A and influenza B virus were tested employing various ion exhange monolithic columns.

Attachments

Full view

During the last decade important developments in molecular medicine and adenoviral vector design have been achieved, leading to an increased use of adenoviral vectors in clinical gene therapy protocols. One of the main advantages of the adenovirus is their ability to replicate at high titres in permisive cell lines. The availability of large quantities of adenoviral vector preparations is recognized as an important limitation to pre-clinical and clinical studies. Consequently there is a global focus on large scale production of adenoviral vectors, providing high titres combined with fast, effective and reliable purification methods.

Attachments

Full view

2007

A number of IgM monoclonal antibodies are currently in development for treatment of autoimmune disease, infectious disease, and cancer. Growing interest in these molecules has created a need for an accurate, rapid, simple analytical method to measure IgM levels in cell culture supernatants, and to document the distribution of IgM and protein contaminants in chromatography fractions. High performance protein A columns are used for this application with IgG monoclonals, but IgMs are easily denatured by the harsh conditions required for elution of most affinity ligands. However, IgM monoclonals often exhibit strong retention on either cation exchangers, or anion exchangers, or both, making ion exchange chromatography a potential candidate for this application.

The large size of IgMs makes them a major challenge to particle-based chromatography media. Pentameric IgM has a mass of about 0.96 Md, and hexameric IgM about 1.15 Md. Their diffusion constants are about 2.5 x10-7 cm2/sec, about twice as slow as IgG. Since particle-based chromatography media mostly rely on diffusion for mass transport, both resolution and capacity are im- Figure 4 illustrates a modified anion exchange gradient configuration for monitoring the amount of IgM expressed in cell culture supernatants. A wash step was introduced to better remove con- paired, and increasingly so at higher flow rates.

Monolithic ion exchangers are characterized by an interconnected system of channels with diameters ranging 0.5 to 2.0 microns. This pore architecture supports convective flow, which conserves high resolution at high flow rates.[1] The lack of a void volume removes the major source of dispersion in chromatographic systems. This contributes to sharper peaks, which improves both resolution and sensitivity. Capacity is also conserved at high flow rates. This permits use of a microcolumn format that minimizes assay time and buffer consumption. This combination of features should make monoliths effective analytical tools for IgM.

Attachments

Full view

Membrane based anion exchangers are being used increasingly for purification of monoclonal antibodies. The transition from particle-based anion exchangers is driven partly by the convenience of membranes and partly by the cost saving associated with their disposability, however the feature that makes them functionally superior is more effective mass transport.

Attachments

Full view

IgM can be used for several purposes such as early detection of certain diseases or, when labelled, localized cancer tumours. For their purification commonly chromatography is used. Methods for purifying such big molecules (M.w. around 950 kDa) are usually long and time consuming since these molecules have extremely low mobility therefore mass transfer between mobile and stationary phases is significantly reduced. When purified using affinity mode, serious decrease in IgM activity can occur because of long exposure to low pH in which they are unstable. Furthermore, because of their size, the IgM capacity of convenctional resins is rather low. CIM monoliths were already successfully used for fast separation of large molecules. In this work we tested applicability of anion-exchange CIM monolithic columns for preparation of IgM.

Attachments

Full view

2006

Commercially available CIM® disk monolithic columns are intended for very fast analyzes and laboratory purification. Their shape is a compromise to achieve acceptable resolution and binding capacity what make them suitable for wide range of laboratory applications. Separations of complex protein mixtures can be carried out within just a few seconds because of flow unaffected resolution and, on the other hand, purification can be effectuated with high productivity due to flow-unaffected dynamic binding capacity [1]. However, in many cases in the field of molecular biology, only a limited amount of sample is available. In such a case it is beneficial to work with small columns having high resolution or they can be used as affinity columns or bioreactors saving significant amount of valuable ligand. Having this goal in mind we developed CIM® disks with the volume of 1/10th and 1/100th of original volume. In comparison to conventional CIM® disks, they exhibit higher resolution and lower limit of detection, therefore smaller concentrations of target macromolecules can be detected. The separation ability and the protein capacity were tested on anion and cation exchange 3.4 mL and 34m L mini disk monolithic columns.

Attachments

Full view

Analysis of a large numbers of samples requires chromatographic supports that not only enable fast separation and purification of a target biomolecules from a complex matrix but are also involved in an automation process. The 96 – microtiter plate format enables both. Although they are routinely used for decade's only recently few reports about the microtiter plates bearing monoliths as a separation media, were reported [1]. Because of advantageous properties such as flow unaffected dynamic binding capacity and resolution 96 - microtiter plates with methacrylate based monolith were prepared. Characterisation of such plate demonstrated that uniform flow rate can be achieved through all wells and no leakage is present. Efficient separation of proteins was achieved within minute. Furthermore CLC (Conjoined Liquid Chromatography) concept [2] originally derived for analytical columns on CIM disk, can easily be extrapolated to microtiter plates. We demonstrated that multidimensional chromatography with 96 – well plate is feasible and can further accelerate screening processes.

Attachments

Full view

2005

The Inter-alpha inhibitor protein family is comprised of complex plasma proteins that consist of a combination of multiple polypeptide chains (light and heavy chains) covalently linked by a chondroitin sulfate chain. The major forms found in human plasma in high concentration are Inter-alpha inhibitor (Ial), which consists of two heavy chains (Hl & H2) and a single light chain, and Pre-alpha Inhibitor (Pal), which consists of one heavy (H3) and one light chain (Fig 1). The light chain (bikunin) is known to inhibit several serine proteases, such as trypsin, human leukocyte chistase, plasmin and cathepsin G which are involved in inflammation, sepsis, tumor invasion and formation of metastasis. Recently, a monoclonal antibody against human inter-alpha inhibitor proteins (MAli 6931) was developed in our laboratory.

Attachments

Full view

The analysis of molecular interactions is a key part of the drug discovery process, and analytical techniques are available for studying in vitro the ligand/target complex since the early stage of the drug development process.

With regard to the assessment of the activity of chemical libraries, the affinity chromatography on HPLC immobilized-enzyme column (or immobilized enzyme reactors, IMER) is one of most promising methodologies for HTS applications.

Human recombinant acetylcholinesterase (hAChE) represents a well-known target for drug-discovery in Alzheimer’s Disease.

Attachments

Full view

Immobilized Metal-Affinity Chromatography (IMAC) is a chromatographic separation technique primarily used for the purification of proteins with exposed histidine residues and for recombinant proteins with histidine tags. Technique uses covalently bound chelating compounds on chromatographic supports to entrap metal ions, such as Cu2+, Ni2+, Zn2+, Co2+, which serve as affinity ligands for various proteins. CIM Convective Interaction Media is a monolithic chromatographic support intended for separation of large biomolecules, such as proteins, DNA and also viruses.

Attachments

Full view

Immobilized Metal-Affinity Chromatography (IMAC) is a separation technique primarily intended for the purification of proteins with exposed histidine tags. Technique uses covalently bound chelating compounds on chromatographic supports to entrap metal ions, which serve as affinity ligands for various proteins. Iminodiacetic acid (IDA), nitrilotriacetic acid (NTA), carboxymethylated aspartic acid (CM-Asp), and N,N,N’-tris(carboximethyl) ethylenediamine (TED) are chelating compounds, most often used to entrap metal ions, such as Cu2+, Ni2+, Zn2+, Co2+ etc.

Convective Interaction Media CIM® is a monolithic support, which provides high rates of mass transfer at low pressure drops. It has been shown that CIM® supports are very efficient for the separation of large molecules, such as proteins and DNA (1). Recent publication has proved that CIM IMAC column can be used for separation of histidine containing peptides (2). Since efficient separation of large molecules is one of the main advantages of CIM® support, purification of His-tagged recombinant proteins on CIM IMAC column should be not only feasible but also simple, fast and efficient.

Attachments

Full view

Viruses have proven to be useful vectors for gene therapy purposes. As therapeutics for human use they must be pure and contaminant free. Traditionally, viruses are purified by complicated and time consuming methods such as CsCl density gradient centrifugation or similar. In recent years liquid chromatography has became interesting method for virus purification. It provides high level of purity required for human use and increases productivity. Traditional chromatographic supports were mostly designed for purification of proteins and as such are commonly inappropriate for viruses. Alternative to traditional chromatographic support are methacrylate monoliths (CIM monoliths), characterized by large channel diameter, high surface accessibility and convective mass transport.

The aim of this work was to characterize CIM supports for separation and possible purification of a model virus Tomato mosaic virus (ToMV) from crude plant material.

Attachments

Full view

Affinity chromatography is a key method for protein purification. Its main advantage is in the high specificity which enables purification of a single protein from complex biological mixtures. For practical use the specific ligand should be immobilised on insoluble matrix. As a matrix, standard chromatographic supports are commonly used. They are normally in form of small (some m in diameter) particles containing pores to provide high specific surface resulting in high binding capacity. The pores are normally closed on one side, thus the liquid inside them is stagnant and the molecules are transported to the active site by diffusion. Since the diffusion coefficients for macromolecules, such as proteins, are very low, diffusion determines the overall process dynamics. As a consequence, separation or purification of the proteins takes normally 0.5 to 1h even on analytical scale.

Attachments

Full view

A large number of diagnostics and several therapeutic monoclonal antibodies (mAbs) have been approved worldwide and many more are expected to be approved and licensed in the near future. The reality and the fact that purification or downstream processing can contribute up to 80% of the total production costs of a biopharmaceutical, enhance the need for efficient purification methods. Liquid chromatography provide high level of purity required for human use, increases productivity and has therfore become the method of choice for purification of biopharmaceuticals.

Purification of mAbs can be achieved by a number of chromatographic methods, Protein A and Protein G affinity chromatography being especially powerful enabling high product purity with single chromatographic step.

Attachments

Full view