Lipid nanoparticles (are leading non viral carriers for therapeutics, offering versatility in encapsulating diverse payloads Their manufacturing superiority over viral systems allows for modularity, speed, and scalability However, this modularity poses challenges in purification and characterization due to sample uniqueness LNPs require downstream processing for in vivo application and adherence to critical quality attributes ( Analytical methods for those currently predominantly require undesirable particle disassembly beforehand.

Monolithic columns offer ideal chromatography for LNPs due to laminar flow, minimizing shear forces, and surface modification enabling selective options Here is presented the purification method for LNPs on monolithic columns utilizing the PATfix® analytical chromatographic system, efficiently separating LNPs from free cargo.

An analytical scale two dimensional chromatographic tool was developed It delivers comprehensive characterization of encapsulation efficiency, nucleic acid content, degradation, and separation of co encapsulated cargos, without any sample pre treatment Highly tunable and automatable, this method maximizes efficiency and facilitates precise separation of LNP populations.

Attachments

Full view

2023

Extracellular vesicles (EVs) are a diverse group of particles secreted by all living cells. Numerous different therapeutic applications of both native and engineered EVs are currently in different stages of clinical development. Nevertheless, considerable challenges are still present in the manufacturing, purification and analytics of EVs. Many factors can influence the final product, therefore an all-inclusive approach to development of the bioprocess is needed. Cell culture parameters and production platform selection might alter the number and composition of EVs. Furthermore, raw materials used in upstream production, such as media and supplements, can greatly impact the chromatographic purification. In this study, we evaluated EV production in different HEK293-derived cell lines. Separation on a strong anion exchange column CIMmultus®-EV was used to assess the abundance of different EV populations. Multi-detector PATfix® SEC analytics coupled with antibody labeling was then used to analyze chromatographic fractions. Furthermore, the analytical methods and performance in downstream processing were applied in the optimization of the upstream process.

Attachments

Full view

Cells release extracellular vesicles (EVs) of different sizes and intracellular origin. Due to their heterogenicity, the isolation of the target EV population from a mixture of supernatant-derived particles can be challenging. Anion exchange chromatography (AEX) exploits the negative charge on EV surface molecules for binding to the positively charged solid phase. CIMmultus® EV, an AEX chromatography monolith column, can separate EVs in subpopulations based on charge and offers insight into the heterogenicity of particles. Besides the availability of preparative tools for separation, combining multiple orthogonal and complementary characterization tools is crucial for defining the EV product of interest. In this work, we used a multiple-detector PATfix® system for the analysis of CIMmultus EV-fractionated samples. Samples were analyzed for the presence of EV-related tetraspanins using the fluorescence detector. PATfix MALS 3609 detector was used for the analysis of particle-containing samples and calculation of particle sizes.

Attachments

Full view

2022

Extracellular vesicles (EV) are lipid bound products secreted by cells. Among them, exosomes have great potential for clinical applications. Animal and human-derived components used in cell culture, such as fetal bovine serum (FBS), naturally contain exosomes that can cross-contaminate the desired product. In order to study exosomes derived from cells of interest, multiple producers have come up with exosome-depleted FBS (EV (-) FBS) generated using different approaches. In this work we evaluated commercially available EV (-) FBS supplements for residual exosome content and tested their performance in upstream exosome production process. The analysis was performed with PATfix high pressure liquid chromatography system using PATfix size exclusion (SEC) analytical method.

Attachments

Full view

2020

Removal of host cell DNA is essential for all human-injectable biologics. This poster shows a method for achieving low host cell levels in preparations of exosomes. Purified exosome samples were prepared with anion exchange chromatography (AEC) and pre-treated with tangetial flow filtration (TFF) and nuclease treatment. Results are compared with an experimental control using TFF and size exclusion chromatohraphy (SEC).

The steps in purification process are illustrated by analytical size exclusion chromatography (SEC) on PATfix system with in-line UV, MALS and fluorescence detectors and by staining with Picogreen reagent. This technique visualizes sample composition by size, UV, light scattering and fluorescent properties.

Attachments

Full view

2019

Exosomes fulfill a critical role as communicators among cells, with targeting and message content depending on their surface receptors and payload. This makes them obvious candidates for an extensive range of diagnostic, therapeutic applications and a need for a fast, robust and scalable purification procedure.

CIMmultus™ monolithic columns are designed to meet the special fractionation needs of very large biologics like exosomes.

We show examples of exosome purification from cell culture with CORNERSTONE Exosome Process Development Pack and analysis of exosomal vesicle populations by Image stream flow cytometry.

Attachments

Full view

This poster shows how Multi-Angle Light Scattering detector and Fluorescence detector couppled to PATfix analytical system can be used to track extracellular vesicles through purification process. Samples were analyzed by analytical size exclusion chromatography (SEC). On SEC cell culture components diffuze into pores of chromatographic media and are separated (mostly) based on size. Particles larger than the media pore size are excluded in the void peak. This peak represents extracellular vesicles including apoptosomes, microvesicles and exosomes as well as cell debris and aggregates.

Attachments

Full view

2014

Exosomes are nano-sized vesicles that are released by many different cell types. They are involved in the transport of a wide range of signalling molecules, including mRNA, microRNA and proteins. Exosomes have been found into body fluids and multiple roles have been ascribed to exosomes, in particular in cell signalling where it has been demonstrated their correlation to disease progression and their overexpression as specific tumour cell biomarkers, suggesting their important role in their diagnosis.

This initial screening oriented towards the separation of exosomes from a cell culture supernatant, has been developed by BIA Separations in collaboration with Exosomics Siena. Exosomes used for this study were cultivated in two different cell lines, MeWo and LNCap, and, after the harvesting, a relatively pure target molecule was obtained after several centrifugations, filtrations and batch affinity capture step with a commercial purification kit. In order to speed-up the process and bring current DSP on a higher level, a novel purification approach based on chromatography, using CIM® monolithic columns was investigated. Monolithic supports represent a new generation of chromatographic media. Due to their large inner channel diameters and enhanced mass transfer characteristics, methacrylate monoliths offer efficient and fast separation of large biomolecules like vescicles, pDNA, viruses and monoclonal antibodies. High binding capacity, good product recovery and resolution are also benefits of monoliths. Different samples, (Standard batch purified exosomes, Culture supernatant filtered, Culture supernatant non-filtered), derived from MeWo and LNCap culture media,, were screened. QA, SO3, DEAE and OH CIM 1mL tube - 6μm pore size were screened. CIM® QA - 6μm pores was chosen.

Attachments

Full view

2005

The rapidly growing interest in the area of proteomics induces intensive efforts to find robust, automated and sensitive high-throughput analytical tools. In this context, the concept of solid-phase digestion (ex. trypsin immobilization on a solid support[1]) has received great attention in the last years. Trypsin (EC 3.4.21.4) has been covalently immobilized on different monolithic supports and resulting bioreactors used as immobilized enzyme reactors (IMERs) for on-line digestion, peptide separation and peptide mapping. Bioreactors efficiencies were evaluated with different recombinant proteins after on-line digestion. The technique used for the separation and identification of peptides was high-performance liquid chromatography coupled with electrospray ionisation tandem mass spectrometry (LC-ESI-MS/MS).

Attachments

Full view

2003

The only four drugs approved for the clinical treatment of Alzheirner’s Disease (tacrine. rivastigmine, donepezil and galantamine) are acetylcholinesterase inhibitors which act by maintaining high levels of acetylcholine at the muscarinic and nicotinic receptors in the central nervous system. Human acetylcholinesterase (HuAChE) represents a widely studied target enzyme and it is still object of research for the development of new drugs as enzyme inhibitors.

In a previous paper we reported the immobilisation of AChE on a silica based chromatographic column (50 x 4.6 mm 1.0.) The yeld of immobilization and the stability of the AChE-IMER were considered satisfactory, but some problems arose. The length of the IMER and the large amount of enzyme covalently bound to the chromatographic support resulted in catalysis product long elution times and some inhibitors aspecific matrix absorption with delayed enzyme activity recovery. In order to avoid these complications and considering the high rate of AChE enzymatic reaction. we decided to reduce the dimension of the solid support for immobilization, hence the amount of immobilized enzyme, by selecting a monolithic matrix disk (12 x 3 mm I.D.).

CIM® (Convective Interaction Media) monolithic supports (Biaseparations. Lubiana) represent a novel generation of stationary phases used for liquid chromatography, bioconversions, and solid phase synthesis. As opposed to individual particles packed into chromatographic columns, CIM® supports are cast as continuous homogeneous phases and provide high rates of mass transfer at lower back pressure.

In the present work a CIMK disk with immobilised human recombinant acetylcholinesterase (HuAChE-ClM® Disk) was developed. The activity of immohilised enzyme, the long term stability and reproducibility were tested. HuAChE-CIM® disk was applied as an immobilised enzyme micro-reactor (micro-IMER) in on-line HPLC system for inhibitory potency determination of known AChE inhibitors.

Full view

Gene therapy which is becoming more and more important in human health care requires the purification of high molecular mass compounds, so called nanoparticles (e. g. viruses and plasmids). The method of choice to ensure proper purity would be chromatography.

Most of the chromatographic supports available on the market at the moment can not follow the requests for such work due to low binding capacity for large molecules, limitation with regards to the time of the separation process and requests for CIP (cleaning in place) and SIP (sanitation in place).

Monolithic supports represent a new generation of chromatographic supports. In contrast to conventional particle supports, where the void volume between individual porous particles is unavoidable, these supports consist of a single monolith highly interconnected with larger and smaller open flow-through channels. Due to the structure, molecules to be separated are transported to the active sites on the stationary phase by convection, resulting in very short separation times. This is especially true for large molecules.

In this work we will present the use of monolithic supports for the separation of different nanoparticles on analytical and preparative scales. It will be shown that monolithic supports can overcome the limitations of particle-based supports for the analytics and isolation of big molecules and represent a major step towards the safe and efficient purification or production of nanoparticles.

Attachments

Full view

Traces of DNA in RNA samples represent impurities that could affect results of mRNA quantification and cDNA synthesis. In most cases, the DNA impurities in RNA samples are removed using enzyme deoxyribonuclease (DNase), which specifically breaks down DNA. In order to avoid the addition of DNase into the analyzing sample, the use of immobilized DNase on solid support is recommended. Because of the DNA size, very few supports available on the market enable efficient interaction between immobilized enzyme and DNA.

In recent years a new group of supports named monoliths was introduced. Because of enhanced exchange between mobile and stationary phase separation and bioconversion processes are significantly accelerated. Therefore also the efficiency of DNA removal using immobilised enzyme might be competitive to the degradation with free enzyme.

Attachments

Full view

2000

Strains of the anaerobic bacterial genus are thought to play an important role in fiber degradation. sp. Mz5 was previously isolated from the rumen of a black and white Friesian cow and its xylanolytic activity was proved to be at least 1,65 times higher than the activities of all of the compared well known xylan-degrading rumen bacterial species and strains (1). High xylanolytic activity was the reason for partial isolation of its xylanases in order to study their special characteristics and possible biotechnological applications later.

Attachments

Full view

1999

High performance membrane chromatography (HPMC) proved to be a very efficient method for fast protein separations. Recently, it was shown to be applicable also for the isocratic separation of plasmid DNAconformations. However, no study about the separation of small molecules was performed until now. In this work, we investigated the possibility of gradient and isocratic separations of small molecules with Convective Interaction Media (CIM) disks of different chemistries. We proved that it was possible to achieve efficient separations of oligonucleotides and peptides in the ion-exchange mode as well as the separation of small hydrophobic molecules in the reversed phase mode. Fairly good separation of four oligonucleotides could be achieved on the disk of 0.3 mm thickness. The effect of the gradient parameters on the resolution in the case of gradient mode was studied and compared with the separation under isocratic conditions.

It was shown that similar peak resolution can be achieved in both gradient and isocratic modes. In addition, it was found that the flow rate does not have a pronounced influence on the resolution in the flow rate range between 1 and 10 mL/min. However, it seems that the resolution with the flow rate even slightly increases as a consequence of the increased pore accessibility. In accordance with conventional particle HPLC columns, the resolution increases with the monolith thickness. On the other hand, the mobile phase composition has to be carefully adjusted to obtain optimal resolution, especially in the case of isocratic separations. Because of this feature, CIM monoliths seem to be competitive to other, commercially available stationary phases.

Attachments

Full view

Organic acids are important metabolites of several biochemical pathways in microorganisms and as such they are frequent main or by-products in different bioprocesses. Consequently, a demand for their monitoring is often present. One of the most applied methods for organic acids determination is certainly HPLC using different separation mechanisms such as reversed-phase, ion-exchange or ion-exclusion chromatography, all based on separation under isocratic flow conditions. To achieve the isocratic separation, multiple steps of adsorption-desorption process are needed and therefore conventional chromatographic columns with long layer of separation material were considered as a necessary tool for achieving this effect.

Recently, it was shown that isocratic separation could also be performed on thin monolithic layers. The isocratic separations of plasmid DNA conformers (1), oligonucleotides (2, 3) and peptides (3) in the ion-exchange mode were demonstrated as well as isocratic reversed-phase separation of a mixture of steroids was obtained (3) all on thin GMA-EDMA monoliths commercially available under trademark CIM™ (Convective Interaction Media). The results indicated the possibility of applying CIM™ monolithic columns also for isocratic separation of some other small charged molecules. Since the average analysis time using CIM™ disk monolithic columns is up to a few minutes, these supports can be a material of choice for separation of organic acids.

Attachments

Full view

CIM® supports are novel monolithic chromatographic supports. In contrast to conventional particle based chromatographic supports they consist of a single porous polymer. The pores form a highly interconnected network, which enables the flow of the mobile phase through the monolith. Molecules to be separated are transported to the surface by the convection. Since the diffusion is not a bottleneck any more, also the resolution and the dynamic capacity of the monolith are flow independent and an average analysis time is typically below one minute. Furthermore, CIM® columns were successfully applied for the purification of proteins directly from the fermentation broth.

Manganese peroxidases (MnP) and lignin peroxidases (LiP) are a family of glicosilated hemo-proteins, which are excreted into the growth medium during the idiophasic growth of the white rot fungus Phanerochaete chrysosporium. They are both involved in the lignin degradation. For their analysis and separation from the growth medium, HPLC is commonly applied. Besides the separation by Na-acetate concentration gradient (2), also the chromatofocusing can be used (3). A fast method for LiP isoenzyme separation from the growth medium of P. chrysosporium using CIM™ QA disk monolithic columns has been recently developed (1). A modified method was tested on the growth medium containing MnP isoenzymes.

Attachments

Full view

The aim of our work was to study the direct monitoring and purification of proteins from the fermentation broth using ion-exchange CIM® supports. Therefore, we studied the possibility of monitoring and purifying lignin peroxidase extracelular protein isoforms produced by the fungus Phanerochaete chrysosporium. These isoenzymes which also differ in their catalytic properties are able to partially depolymerize lignin and to oxidise several xenobiotics.

Attachments

Full view

The white rot fungus Phanerochaete chrysosporium under nitrogen or carbon limitation produces extracellular lignin peroxidases (LiP). They are able to partially depolymerize lignin and to oxidize several xenobiotics (DDT, PCB, PAH, etc.). By HPLC separation and isoelectric focusing multiple molecular forms of LiP have been isolated from the culture filtrate. For the isolation of LiP from the growth medium, mostly the HPLC technique with ion exchange Mono-Q or DEAE columns is used. The medium should be dialyzed before separation and usually also concentrated. Medium freezing is used to remove mucilaginous polysaccharides which disturb separation. The whole procedure is time consuming and information about isoenzyme content and their relative amounts in the growth medium is delayed for at least 1 day. HPLC separation itself lasts nearly an hour. For the separation of LiP isoenzymes from the culture filtrate, we used the monolithic stationary phase with weak (DEAE-diethylamine) and strong (QA-quaternary amine) ion exchange groups commercially available under trademark CIM (Convective Interaction Media). CIM supports are glycidyl methacrylate based monolithic porous polymer supports. As such they differ from conventional particle shaped chromatographic supports. The liquid is forced to flow through the support channels. Molecules to be separated are transported mainly by convection resulting in travelling times shorter for at least an order of magnitude. As a consequence the resolution as well as the binding capacity remain unaffected with the flow rate and a shorter analysis time can be achieved. This effect is even more pronounced in the case of large molecules such as proteins, which have a low diffusion coefficient. As such, CIM units can be advantageous also for lignin peroxidase isoenzymes separation and purification.

Attachments

Full view

1998

White rot fungus Phanerochaete chrysosporium produces under nitrogen limitation extracellular lignin peroxidases (LiP). They are able to partially depolymerize lignin and to oxidise several xenobiotics (DDT, PCB, PAH,…) and synthetic dyes. Trough HPLC separation and isoelectric focusing multiple molecular forms of LiP have been determined and isolated from the culture filtrate. Depending on growth conditions, separation technique, strain employed and culture age 2-15 different LiP izoenzymes were observed in culture media of Phanerochaete chrysosporium. They are structurally similar but differ in stability, quantity and in catalytic properties. For the isolation of LiP from growth medium, mostly the procedure employing HPLC ionexchange columns as shown on Scheme 1 is used. For the separation of LiP isoenzymes from the culture filtrate, we used CIM (Convective Interaction Media) units. Their advantage is very fast separation of macromolecules due to their particular threedimensional structure. In contrast to particle supports containing closed pores, CIM units consist of monolith porous material containing flow through pores. Therefore, macromolecules to be separated are transported to the active site by convection rather than by diffusion. As a consequence, the separation resolution and dynamic binding capacity are flow independent. As such CIM units can be advantageous also for lignin peroxidase isoenzymes separation and purification.

Attachments

Full view