On May 12th, the biaseparations.com website will be retired and migrated tosartorius.com.Learn moreabout our combined offering today!
2024

Lipid nanoparticles (are leading non viral carriers for therapeutics, offering versatility in encapsulating diverse payloads Their manufacturing superiority over viral systems allows for modularity, speed, and scalability However, this modularity poses challenges in purification and characterization due to sample uniqueness LNPs require downstream processing for in vivo application and adherence to critical quality attributes ( Analytical methods for those currently predominantly require undesirable particle disassembly beforehand.

Monolithic columns offer ideal chromatography for LNPs due to laminar flow, minimizing shear forces, and surface modification enabling selective options Here is presented the purification method for LNPs on monolithic columns utilizing the PATfix® analytical chromatographic system, efficiently separating LNPs from free cargo.

An analytical scale two dimensional chromatographic tool was developed It delivers comprehensive characterization of encapsulation efficiency, nucleic acid content, degradation, and separation of co encapsulated cargos, without any sample pre treatment Highly tunable and automatable, this method maximizes efficiency and facilitates precise separation of LNP populations.

Attachments

Full view

2023

Extracellular vesicles (EVs) are a diverse group of particles secreted by all living cells. Numerous different therapeutic applications of both native and engineered EVs are currently in different stages of clinical development. Nevertheless, considerable challenges are still present in the manufacturing, purification and analytics of EVs. Many factors can influence the final product, therefore an all-inclusive approach to development of the bioprocess is needed. Cell culture parameters and production platform selection might alter the number and composition of EVs. Furthermore, raw materials used in upstream production, such as media and supplements, can greatly impact the chromatographic purification. In this study, we evaluated EV production in different HEK293-derived cell lines. Separation on a strong anion exchange column CIMmultus®-EV was used to assess the abundance of different EV populations. Multi-detector PATfix® SEC analytics coupled with antibody labeling was then used to analyze chromatographic fractions. Furthermore, the analytical methods and performance in downstream processing were applied in the optimization of the upstream process.

Attachments

Full view

Cells release extracellular vesicles (EVs) of different sizes and intracellular origin. Due to their heterogenicity, the isolation of the target EV population from a mixture of supernatant-derived particles can be challenging. Anion exchange chromatography (AEX) exploits the negative charge on EV surface molecules for binding to the positively charged solid phase. CIMmultus® EV, an AEX chromatography monolith column, can separate EVs in subpopulations based on charge and offers insight into the heterogenicity of particles. Besides the availability of preparative tools for separation, combining multiple orthogonal and complementary characterization tools is crucial for defining the EV product of interest. In this work, we used a multiple-detector PATfix® system for the analysis of CIMmultus EV-fractionated samples. Samples were analyzed for the presence of EV-related tetraspanins using the fluorescence detector. PATfix MALS 3609 detector was used for the analysis of particle-containing samples and calculation of particle sizes.

Attachments

Full view

mRNA has been at the forefront of both scientific and general public interests from the start of the COVID-19 pandemic. However, there are still limited options available for rapid characterization of mRNA containing samples. For precise characterization of an mRNA sample, first the presence and concentration of mRNA molecules in the sample needs to be identified. In the second step, any contaminants in the sample coming from the IVT reaction need to be identified and quantified. All major components of the IVT reaction; nucleotides, capping reagent, enzymes and DNA template may be present in the mRNA sample. In addition, impurities such as shorter, incomplete RNA fragments, and in particular, dsRNA may also be present. Contaminants may also come from the mRNA in vitro instability, caused by spontaneous hydrolyzation of the mRNA backbone. These issues can be mitigated using appropriate analytical tools throughout the mRNA production and purification steps.

Attachments

Full view

2022

Adenovirus is well-know gene therapy tool that gained attention as a promising vaccine delivery vehicle, specially during Covid-19 pandemics, where it was used to deliver sequence for protein S (S). Multiple serotypes have been tested in clinical trials for various applications, the most common one being human adenovirus serotype 5 (Ad5). With this in mind, we chose Ad5-S construct with GFP tag as a model vector to develop upstream process (USP) and supporting analytical tools.

Attachments

Full view

Endotoxins are robust and persistent impurity, which are native to majority of phage substrates. Two anion exchangers, CIMmultus PrimaS and H-Bond, were tested for their capacity for endotoxin removal in comparison to well known strong anion exchanger, CIMmultus QA. 

Attachments

Full view

Recombinant adeno-associated viral (rAAV) vectors are the leading gene delivery tool for treatment of a variety of diseases. While several rAAV mediated therapies have been approved so far, and many more are in clinical trials, rAAV production still faces many challenges. Key goal of rAAV upstream process development is achievieng high viral titer together with a sufficient percentage of full capsids. Moreover, analysis of complex upstream harvest samples can be challenging. Classical analytical methods such as ddPCR/ELISA offer limited information due to differences in sample preparation and basic principles for detecting empty and full capsids. Method is also time consuming and therefore less useful for following rAAV production process in real time. To overcome these limitations, we developed a PATfix Valve Switch analytical method that is based on ion exchange biochromatography and can be successfully applied for analysis of empty/full ratios in crude upstream samples.

Attachments

Full view

Extracellular vesicles (EV) are lipid bound products secreted by cells. Among them, exosomes have great potential for clinical applications. Animal and human-derived components used in cell culture, such as fetal bovine serum (FBS), naturally contain exosomes that can cross-contaminate the desired product. In order to study exosomes derived from cells of interest, multiple producers have come up with exosome-depleted FBS (EV (-) FBS) generated using different approaches. In this work we evaluated commercially available EV (-) FBS supplements for residual exosome content and tested their performance in upstream exosome production process. The analysis was performed with PATfix high pressure liquid chromatography system using PATfix size exclusion (SEC) analytical method.

Attachments

Full view

2021

The IVT reaction is one of the most expensive steps in mRNA production process and its optimization to reach high mRNA yield is of key importance Standard mRNA quantification techniques like absorbance and fluorescence based assays are time consuming and cannot be performed at line as the IVT reaction progresses In addition, other reaction components like nucleotides and pDNA interfere in the analytical results and reduce the method’s accuracy A new approach shown here uses CIMac PrimaS™ analytical HPLC column to separate and quantify several key IVT components with a very short run time, enabling fast “at line” tracking

Attachments

Full view

Density gradient ultracentrifugation (DGUC) is a well established tool for Empty/ Full AAV capsid separation based on density differences between AVV sub-populations. However DGUC practice is laborious and lacks any detection options, therefore fractions must be collected manually and analyzed later. Both of these shortcomings can be addressed by coupling post DGUC workflow to PATfix analytical system. BIA Separations PATfix platform provides sufficient tools for liquid extraction and fractionation as well as a comprehensive detector suite for precise fraction characterization. Baseline separation of capsid species was achieved in a density gradient of CsCl, producing a centrifugram that reveals information traditional DGUC and anion exchange chromatography cannot.

Attachments

Full view

Optimizing processing steps in sc pDNA isolation is critical for obtaining good process yields as well as high product purity. PATfix platform with convective chromatography media (e.g. monolith) offers a rapid analytical method to characterize complex biomolecular mixtures and gives immediate feedback during process development. E coli lysis represents such a challenging step, where multiple critical quality attributes need to be identified and critical processing parameters optimized. This approach leads to better yields and product purity, allowing for simplified downstream steps. A new PATfix analytical platform presented here uses CIMac pDNA column, to separate and characterize plasmid from impurities, allowing for easy optimization of key parameters such as RNA removal.

Attachments

Full view

2019

AAV vector lots are generally a heterogeneous mixture of empty particles (i e do not contain DNA) and full particles (i.e. contain DNA). Different spectrometric based methods can be used to establish the ratio between full and empty AAV particles, but accurate evaluation of empty/full ratio is often obstructed due to complex spectroscopic behavior of empty and full AAV particles, such as poor separation and impurity overlapping. An approach that takes difference in physical chemical properties between empty and full capsids into account overcomes limitations of spectrometric based evaluation of empty and full AAV particle ratio.

Chromatographic separation of empty and full AAV 2 8 capsids was achieved on the CIMac AAV full/empty analytical column (strong anion exchanger, QA quaternary amine chemistry) with the PATfix™ system using a linear NaCl gradient at pH 9.0 Signal response from three different detectors connected in series was analyzed fluorescence (excitation 280 nm emission 348 nm), light scattering 90 angle, LS) and UV absorbance 260 nm and 280 nm).

Attachments

Full view

One of the handicaps of working with bacteriophages is the long duration required to perform plaque assays. Plaque assays also impose questions about accuracy and precision relative to the scale and experience of the persons performing and interpreting them. This poster presents a pair of high precision, high accuracy chromatography-based assays that permit determination of phage concentration in less than 1 hour. Sensitivity of UV absorbance is poor because of the low concentration of phages. However, phage sensitivity is strongly amplified by monitoring the chromatogram with either fluorescence or MALS. Fluorescence works by measuring the fluorescence emission from tryptophan residues of the phage proteins. MALS works by passing a laser beam through the sample and reading the scatter produced when it encounters a particle. Larger species generate more scatter.

Attachments

Full view

Bacteriophages represent immense potential as therapeutic agents. Many of the most compelling applications of bacteriophages involve human therapy, some pertinent to gene therapy, others involving antibiotic replacement. In bacteriophage research and therapy, most applications ask for highly purified phage suspensions, as such it is crucial to reduce proteins, endotoxins, DNA and other contaminants. The most common technique for purification is ultracentrifugation using cesium chloride gradients. This technique is elaborate, cumbersome, expensive and difficult to scale-up.
Alternative techniques for purification are usually time consuming and affect phage recovery and/or viability. In this study we present efficient two-step chromatographic purification method with binding phages to a stationary phase - Convective Interaction Media (CIM®) monoliths. The aim of the study was to develop robust, fast and effective virus purification platform that can be used for several types of bacteriophages for any application. In this work bacterial lysate with bacteriophage T4 (host E.Coli) was used.

Attachments

Full view

2017

Production of high value biological therapeutics usually involves complex manufacturing processes with high process variability. Additionally, development of robust and reliable bioprocesses can be challenging. PAT aims to enhance bioprocess understanding and implies a holistic approach to ensure that quality is built into products by design. Efficient PAT therefore calls for fast and robust analytical techniques which enables to asses high quality information about critical quality attributes and key performance indicators as parallel as possible to the manufacturing process. PATfix™ is unique analytical system for routine gradient separations that enables every analytical task. Equipped with bio-inert ceramic pump heads is deliberately tailored to meet the demands of analytical applications covering wide range of biomolecules. Highly sensitive and fast multi-wavelength detector enables to detect component peaks even in very fast gradients.

Attachments

Full view

2016

Productivity of the downstream bioprocessing depends among others on the efficiency of chromatographic step. One of the crucial chromatographic parameters is dynamic binding capacity (DBC) for certain biomolecule. DBC could be tailored with changing the surface area of convective pores by tailoring the surface of pre-polymerized monoliths using graft or block polymerization of polymer brushes. Grafted CIM monoliths have already been prepared via Radical Polymerization (RP) and successfully characterized (1).

Recently, the implementation and optimization of Controlled Radical Polymerization (CRP) for grafting of large pore monoliths (average diameter 6 μm ) resulted in polymethacrylate-based ionic exchanger with at least 5 times higher DBC compared to non-grafted 6 μm monoliths, while preserving high permeability. The main goal of our study was to chromatographically characterize novel grafted ion-exchanging monoliths (CIM gDEAE and CIM gSO3) to see whether novel columns still retain flow independent chromatographic properties of non-grafted monoliths.

Attachments

Full view

To ensure the desired chromatographic characteristics of the CIM® monolithic column at large scales, monolith microstructure morphology, pore size distribution, porosity and surface ligand density should be uniform. To demonstrate the uniformity of large chromatographic monoliths we have developed new testing procedures. By fabricating smaller columns (disks) from different random  positions of larger monolith, non-cGMP compliant chromatographic testing can be applied on the same polymerization batch without affecting the cGMP compliance of large-scale chromatographic monolith. Each individual disk was thoroughly tested and the results were compared to the properties of the large monolith.

Attachments

Full view

There are many cases, where a single protein needs to be purified from a complex sample. Such proteins manifest themselves as impurities, which can affect further analysis, either by causing specific equipment malfunction or lower yield in the products. In other cases the specific protein is our molecule of interest, for example in glycomics analysis. In both cases high specificity for proteins, reproducibility and reliability is necessary. We have developed a model immunoaffinity column and 96-well plate based on an anti-fibrinogen monoclonal antibody, covalently immobilized onto CIMac™ analytical chromatographic monolith.

Attachments

Full view

There are many cases, where a single protein needs to be purified from a complex sample. Such proteins manifest themselves as impurities, which can affect further analysis, either by causing specific equipment malfunction or lower yield in the products. In other cases the specific protein is our molecule of interest, for example in glycomics analysis. In both cases high specificity for proteins, reproducibility and reliability is necessary. We have developed a model immunoaffinity column and 96-well plate based on an anti-fibrinogen monoclonal antibody, covalently immobilized onto CIMac™ HDZ analytical chromatographic monolith.

Attachments

Full view

2015

Methacrylate monoliths (CIM® monolithic columns) allow for very fast and efficient separations and exhibit very high binding capacities for extremely large bio-particles due to their large inner channel diameters and enhanced mass transfer characteristics.
Additionally, the ability to manufacture polymer monolithic materials ranging from analytical to large scale preparative/industrial columns has tremendous advantages. By ensuring the chromatographic properties are consistent over the whole size range, one can easily design and optimize a purification method on laboratory scale and transfer it to a production line with minimal to no additional modifications.

Until now the largest monolithic column had a volume of 8 L, which was large enough to serve the biopharmaceutics' market's needs. Now however, the capacity of that column is already at its upper limit.

By successfully employing the knowledge and experience from almost two decades of monolith production we have managed to overcome the size limitations and polymerize the largest convective chromatographic support made from one piece of material, a 40 L monolithic column.

Attachments

Full view