On May 12th, the biaseparations.com website will be retired and migrated tosartorius.com.Learn moreabout our combined offering today!
2001

Ion exchange chromatography is one of the most commonly used techniques for the purification and separation of polar samples such as minerals in water or charged biomolecules (Figure 1).

The technique is based upon reversible binding of the charged species to an oppositely charged group that is attached to an insoluble matrix. A quantitative measure of an ion exchanger’s ability to take up exchangeable counter-ions is its capacity, which strongly influence support properties and can be measured by potentiometric titration with a strong acid or base [2]. However, the time to achieve the ion exchange equilibrium (the stationary state the potentiometric titration is based upon) is very long [3]. Consequently, a new method to measure the total ionic capacity of anion exchange resins is being developed.

Attachments

Full view

2000

CIM® disk monolithic columns are monolithic columns based on glycidyle methacrylate ethylene dimethacrylate copolymers. They have become popular for separation of proteins and polynucleotides. A method for directed synthesis of peptides on these monoliths was developed. With a peptide directed against human blood coagulation factor VIII, the functionality of the CIM® disk monolithic column was checked.

Attachments

Full view

Monoliths are becoming very attractive stationary phases due to their advantageous hydrodynamic characteristics. The main difference in comparison to conventional particle beds is in their structure. Conventional particle based supports consist of few-micrometer sized porous particles while the monoliths consist of a single piece of porous material. The pores are highly interconnected forming a network of channels. Since the flow of the liquid within the channels is driven by the pressure difference, the molecules to be separated are transported to the active sites located on the surface of the channels by convection increasing their mobility by several orders of magnitude. Because of that, it is possible to perform an efficient separation of large molecules within a very short time. Furthermore, the efficiency as well as the dynamic binding capacity are independent on linear velocity within the range of tested flow rates.

Glycidyl methacrylate based monoliths were introduced in 1990. They were polymerised from glycidyl methacrylate (GMA) and ethylene dimethacrylate (EDMA) in the presence of porogens and an initiator. So far they have been successfully applied in a variety of different applications on an analytical scale: for separation and purification of proteins, DNA, smaller molecules like organic acids, hydroxybenzoates, oligonucleotides and peptides as well as sensors incorporated in a FIA system1.

Preparation of large volume GMA-EDMA monoliths is however problematic. The reason is an increase of the temperature inside the monomer mixture during polymerisation since the reaction is highly exothermic. Because of the bulk polymerisation, temperature increase inside the monomer mixture during the polymerisation can not be avoided, resulting in an extremely inhomogeneous structure of the monolith2. In this work, we introduce an approach for the construction of large scale monoliths in the annulus shape and demonstrate their applicability for chromatographic separation and purification.

Attachments

Full view

1999

High performance membrane chromatography (HPMC) proved to be a very efficient method for fast protein separations. Recently, it was shown to be applicable also for the isocratic separation of plasmid DNAconformations. However, no study about the separation of small molecules was performed until now. In this work, we investigated the possibility of gradient and isocratic separations of small molecules with Convective Interaction Media (CIM) disks of different chemistries. We proved that it was possible to achieve efficient separations of oligonucleotides and peptides in the ion-exchange mode as well as the separation of small hydrophobic molecules in the reversed phase mode. Fairly good separation of four oligonucleotides could be achieved on the disk of 0.3 mm thickness. The effect of the gradient parameters on the resolution in the case of gradient mode was studied and compared with the separation under isocratic conditions.

It was shown that similar peak resolution can be achieved in both gradient and isocratic modes. In addition, it was found that the flow rate does not have a pronounced influence on the resolution in the flow rate range between 1 and 10 mL/min. However, it seems that the resolution with the flow rate even slightly increases as a consequence of the increased pore accessibility. In accordance with conventional particle HPLC columns, the resolution increases with the monolith thickness. On the other hand, the mobile phase composition has to be carefully adjusted to obtain optimal resolution, especially in the case of isocratic separations. Because of this feature, CIM monoliths seem to be competitive to other, commercially available stationary phases.

Attachments

Full view

Organic acids are important metabolites of several biochemical pathways in microorganisms and as such they are frequent main or by-products in different bioprocesses. Consequently, a demand for their monitoring is often present. One of the most applied methods for organic acids determination is certainly HPLC using different separation mechanisms such as reversed-phase, ion-exchange or ion-exclusion chromatography, all based on separation under isocratic flow conditions. To achieve the isocratic separation, multiple steps of adsorption-desorption process are needed and therefore conventional chromatographic columns with long layer of separation material were considered as a necessary tool for achieving this effect.

Recently, it was shown that isocratic separation could also be performed on thin monolithic layers. The isocratic separations of plasmid DNA conformers (1), oligonucleotides (2, 3) and peptides (3) in the ion-exchange mode were demonstrated as well as isocratic reversed-phase separation of a mixture of steroids was obtained (3) all on thin GMA-EDMA monoliths commercially available under trademark CIM™ (Convective Interaction Media). The results indicated the possibility of applying CIM™ monolithic columns also for isocratic separation of some other small charged molecules. Since the average analysis time using CIM™ disk monolithic columns is up to a few minutes, these supports can be a material of choice for separation of organic acids.

Attachments

Full view

Synthetic oligonucleotides play an important role as novel therapeutic agents.

One of the most important, but also very time-consuming steps in synthetic oligonucleotides production is their purification. Due to their high-resolution power, reversed-phase and ion-exchange chromatography are the most widely used techniques for these purposes. For the reversed-phase separations oligonucleotides need to be kept as 5'-O-dimethoxytrityl derivatives until the purification process is completed and only then the detritylation takes place. Both these steps lower the yield of the production process. In the contrary, ion-exchange chromatography offers applications to deprotected oligonucleotides directly and that is the reason why this chromatography mode is more preferred.

Convective Interaction Media (CIM) are newly developed polymerbased monolithic supports allowing high resolution separations which can be carried out within seconds in the case of analytical units - disks. This is due to predominantly convective mass transport of biomolecules between the mobile and stationary phase and very low dead volumes. Additionally, the dynamic binding capacity is not affected by high flow rates.

In this work weak (DEAE) anion-exchange CIM supports have been successfully applied for the analysis and purification of synthetic oligonucleotides.

Attachments

Full view

Monolithic chromatographic supports can efficiently be used for fast separation and purification of different types of molecules, both in the analytical and preparative scale. CIM Convective Interaction Media™ monolithic columns are macroporous polymeric supports that allow in-seconds separation of proteins and other biomolecules in gradient and isocratic modes.

In this work, the results showing the main characteristics of CIM™ columns are presented. The breakthrough curves at different flow rates were measured and it is shown that the dynamic binding capacity is practically unaffected by increased flow rates. The adsorption isotherm is almost rectangular exhibiting a highly favourable conditions for binding the tested components to the matrix. Furthermore, relatively high binding capacity is still maintained at elevated ionic strengths of the binding buffer. Finally, the HETP values of the components with different molecular masses are presented.

Attachments

Full view

There are many different chromatographic supports on market. Although main part of them are particle shaped supports, the so-called monoliths are becoming increasingly more important. Particle based supports are commonly uniform-sized of some micron with high porosity. The pores are required to increase the specific surface area and, as a consequence, to increase the binding capacity. Since the pores are closed on one side, the liquid inside them is stagnant and the movement of molecules is governed by diffusion. Therefore, to obtain a good separation and a high binding capacity, low flow rates should commonly be applied. This results in flowdependent resolution of the separation and dynamic binding capacity.

In contrast to conventional porous particles the morphological characteristics of CIM supports are characterised by a single monolithic unit that contains pores, opened on both sides. These pores are highly interconnected forming a flow-through a network. All the mobile phase is forced to run through these open pores, therefore, the mass transfer between stationary and mobile phases is based on convective flow. One of the key features of monolithic units is their pore size distribution that should enable low back pressure at high throughputs together with high specific surface area, needed for high binding capacity.

In this work, dynamic characteristics of CIM disks bearing weak anion exchange groups for binding Bovine Serum Albumin (BSA) were studied. Reproducibility was checked and protein concentration as well as the flow rate were varied. Preliminary results confirm the flow independence of the dynamic binding capacity in the whole range of applied flow rates.

Attachments

Full view

CIM (Convective Interaction Media) represent a new generation of chromatographic supports. In contrast to conventional particle supports, where the void volume between individual porous particles is unavoidable, CIM supports consist of a single monolith with open channels. In this way, molecules to be separated are transported into the pores by convection, resulting in short separation times.

CIMsupports proved to be very efficient for extremely fast separations of proteins in ion exchange, hydrophobic interaction and affinity chromatography mode. Recently, the successful separation of DNA as well as some smaller molecules like e.g. peptides and oligonucleotides were also performed.

All the above mentioned separations were carried out on an analytical scale with the use of 0.34 mL CIM discs. The scale-up of monolithic units was limited mainly due to the problems associated to the mechanical stability, poor sample distribution and higher backpressures. The change from the axial to radial flow enables the design of the so-called 8 and 80mLCIM tubes. They were basically designed for very fast purification of macromolecules.

In this work we present some basic characteristics of these newly developed units in terms of separation and binding capacity. In addition, some practical examples will be given and discussed as well.

Attachments

Full view