On May 12th, the biaseparations.com website will be retired and migrated tosartorius.com.Learn moreabout our combined offering today!
2019

AAV vector lots are generally a heterogeneous mixture of empty particles (i e do not contain DNA) and full particles (i.e. contain DNA). Different spectrometric based methods can be used to establish the ratio between full and empty AAV particles, but accurate evaluation of empty/full ratio is often obstructed due to complex spectroscopic behavior of empty and full AAV particles, such as poor separation and impurity overlapping. An approach that takes difference in physical chemical properties between empty and full capsids into account overcomes limitations of spectrometric based evaluation of empty and full AAV particle ratio.

Chromatographic separation of empty and full AAV 2 8 capsids was achieved on the CIMac AAV full/empty analytical column (strong anion exchanger, QA quaternary amine chemistry) with the PATfix™ system using a linear NaCl gradient at pH 9.0 Signal response from three different detectors connected in series was analyzed fluorescence (excitation 280 nm emission 348 nm), light scattering 90 angle, LS) and UV absorbance 260 nm and 280 nm).

Attachments

Full view

One of the handicaps of working with bacteriophages is the long duration required to perform plaque assays. Plaque assays also impose questions about accuracy and precision relative to the scale and experience of the persons performing and interpreting them. This poster presents a pair of high precision, high accuracy chromatography-based assays that permit determination of phage concentration in less than 1 hour. Sensitivity of UV absorbance is poor because of the low concentration of phages. However, phage sensitivity is strongly amplified by monitoring the chromatogram with either fluorescence or MALS. Fluorescence works by measuring the fluorescence emission from tryptophan residues of the phage proteins. MALS works by passing a laser beam through the sample and reading the scatter produced when it encounters a particle. Larger species generate more scatter.

Attachments

Full view

Bacteriophages represent immense potential as therapeutic agents. Many of the most compelling applications of bacteriophages involve human therapy, some pertinent to gene therapy, others involving antibiotic replacement. In bacteriophage research and therapy, most applications ask for highly purified phage suspensions, as such it is crucial to reduce proteins, endotoxins, DNA and other contaminants. The most common technique for purification is ultracentrifugation using cesium chloride gradients. This technique is elaborate, cumbersome, expensive and difficult to scale-up.
Alternative techniques for purification are usually time consuming and affect phage recovery and/or viability. In this study we present efficient two-step chromatographic purification method with binding phages to a stationary phase - Convective Interaction Media (CIM®) monoliths. The aim of the study was to develop robust, fast and effective virus purification platform that can be used for several types of bacteriophages for any application. In this work bacterial lysate with bacteriophage T4 (host E.Coli) was used.

Attachments

Full view

Serotype 10 adeno-associated virus (AAVrh_10mCherry) was analysed on the PATfix™ system with the CIMac™ AAV full/empty analytical column to estimate the ratio of empty and full AAV particles based on the peak area of the chromatogram given with three different detectors. AAV included a protein capsid containing single stranded DNA. CIMac™ AAV column consisted of a strong anion exchanger with QA chemistry (quaternary amine).

Poster was prepared by Blaz Goricar and presented at ISBioTech 9th Spring Meeting where it was awarded the first prize. Congratulations!

Attachments

Full view

2018

This poster presents fully scalable non-affinity purification strategy that has been proven to be effective for all AAV serotype tested to date. Cell lysate is directly subjected to column purification after removal of cell debris without requiring a concentration step using tangential flow filtration. The process consists of three chromatographic steps. Hydrophobic interaction chromatography on a CIMmultus OH monolith is used for initial virus capture and purification. Precipitating salts are used at 1.0–2.0 M to achieve virus binding. Most of the small molecule contaminants and proteins are eliminated in the flow-through. AAV co-elutes with a highly reduced population of contaminating proteins. DNA-protein complexes are very strongly retained and require NaOH for removal. Intermediate polishing is performed with a CIMmultus SO3 cation exchange monolith. The AAV fraction from the capture step is titrated to a pH value of 3.5—5.0 and diluted to binding conditions. Sugars and surfactants are added to suppress non-specific interactions with tubing and containers, and the product is eluted in a salt gradient. Final polishing is conducted on a CIMmultus QA anion exchange monolith which separates empty capsids from full capsids. This is achieved in a salt gradient at alkaline pH. For more information please refer to BIA Application note A048 (www.biaseparations.com/applications).

Attachments

Full view

Chromatography is a useful purification method for large biomolecules and virus manufacturing and it is easily scalable to large production volumes. Convective Interaction Media (CIM) monolithic columns constitute of large flow-through channels and consequently have high surface accessibility of binding sites. Preferences of CIM monolithic columns are flow independent performance, resulting in fast separation, concentration, purification, impurities removal, and analytics of biopharmaceuticals.
The aim of the study was to develop Influenza virus purification platform, which can be used for several virus strains. The main objective was to develop a process with as little as possible of intermediate steps, especially omitting Tangential Flow Filtration (TFF) or other sample pre-treatments with high host-cell DNA and protein removal, as well as to achieve high binding capacity of the Influenza virus per mL of monolithic support.

Attachments

Full view

During recombinant adeno associated virus (rAAV) downstream processing, a large amount of host-cell and product related impurities needs to be removed from the product. Succesful process on laboratory scale, such as Cesium chloride purification, lacks scalability when the process is due to be transfered to larger industrial scale. The aim of the study was to develop robust, fast and effective rAAV virus purification platform, which can be used for several AAV serotypes with various inserts. Lysed harvest and supernatant of rAAV9 were first captured and concentrated on CIMmultus™ OH column, followed by intermediate step on CIMmultus™ SO3 column and further polishing on CIMmultus™ QA column. Derived purity of industrial scale monolith purification product was compared to laboratory scale purification.

Attachments

Full view

2017

Production of high value biological therapeutics usually involves complex manufacturing processes with high process variability. Additionally, development of robust and reliable bioprocesses can be challenging. PAT aims to enhance bioprocess understanding and implies a holistic approach to ensure that quality is built into products by design. Efficient PAT therefore calls for fast and robust analytical techniques which enables to asses high quality information about critical quality attributes and key performance indicators as parallel as possible to the manufacturing process. PATfix™ is unique analytical system for routine gradient separations that enables every analytical task. Equipped with bio-inert ceramic pump heads is deliberately tailored to meet the demands of analytical applications covering wide range of biomolecules. Highly sensitive and fast multi-wavelength detector enables to detect component peaks even in very fast gradients.

Attachments

Full view

New vaccines against Influenza A are required each year to keep up with the most virulent evolving strains. This highlights a need for predictive analytical tools that can aid purification process development and validation. Rapid and reliable quantification of Influenza A virus is therefore of the utmost importance for enabling good yields and controlling the costs of the downstream processing. Here we demonstrate the ability of monolithic chromatography media to produce process predictive profiles that can document ability to remove impurities and obtain high product recoveries.

CIMac™ Analytical Columns are short bed high performance monolithic columns offering all the advantages of CIM® monolithic technology. Their small volume and short column length allow the operation at high volumetric flow rates enabling to receive the information about the product quantity and purity in just a few minutes. Hence, the CIMac™ Analytical Columns can be effectively used for the in-process and final control of various samples from different purification process steps.

Attachments

Full view

2016

Adeno-associated virus (AAV) vectors of various serotypes are considered to have high potential for gene therapy applications. Currently, manufacturing of AAV vectors faces the challenge of co-production of incompletely formed particles lacking a recombinant viral genome. Empty capsids increase the dose of total AAV administered for efficient transduction and are thought to cause unwanted immunological reactions against the virus.Removal of empty capsids during manufacturing, as well as analysis of empty/full AAV particle content is therefore a critical requirement for any AAV production process. This poster demonstrates how CIMmultus™ QA monolithic columns can be used to remove empty AAV capsids from the product chromatographically in a single step.

Attachments

Full view

Productivity of the downstream bioprocessing depends among others on the efficiency of chromatographic step. One of the crucial chromatographic parameters is dynamic binding capacity (DBC) for certain biomolecule. DBC could be tailored with changing the surface area of convective pores by tailoring the surface of pre-polymerized monoliths using graft or block polymerization of polymer brushes. Grafted CIM monoliths have already been prepared via Radical Polymerization (RP) and successfully characterized (1).

Recently, the implementation and optimization of Controlled Radical Polymerization (CRP) for grafting of large pore monoliths (average diameter 6 μm ) resulted in polymethacrylate-based ionic exchanger with at least 5 times higher DBC compared to non-grafted 6 μm monoliths, while preserving high permeability. The main goal of our study was to chromatographically characterize novel grafted ion-exchanging monoliths (CIM gDEAE and CIM gSO3) to see whether novel columns still retain flow independent chromatographic properties of non-grafted monoliths.

Attachments

Full view

To ensure the desired chromatographic characteristics of the CIM® monolithic column at large scales, monolith microstructure morphology, pore size distribution, porosity and surface ligand density should be uniform. To demonstrate the uniformity of large chromatographic monoliths we have developed new testing procedures. By fabricating smaller columns (disks) from different random  positions of larger monolith, non-cGMP compliant chromatographic testing can be applied on the same polymerization batch without affecting the cGMP compliance of large-scale chromatographic monolith. Each individual disk was thoroughly tested and the results were compared to the properties of the large monolith.

Attachments

Full view

There are many cases, where a single protein needs to be purified from a complex sample. Such proteins manifest themselves as impurities, which can affect further analysis, either by causing specific equipment malfunction or lower yield in the products. In other cases the specific protein is our molecule of interest, for example in glycomics analysis. In both cases high specificity for proteins, reproducibility and reliability is necessary. We have developed a model immunoaffinity column and 96-well plate based on an anti-fibrinogen monoclonal antibody, covalently immobilized onto CIMac™ analytical chromatographic monolith.

Attachments

Full view

There are many cases, where a single protein needs to be purified from a complex sample. Such proteins manifest themselves as impurities, which can affect further analysis, either by causing specific equipment malfunction or lower yield in the products. In other cases the specific protein is our molecule of interest, for example in glycomics analysis. In both cases high specificity for proteins, reproducibility and reliability is necessary. We have developed a model immunoaffinity column and 96-well plate based on an anti-fibrinogen monoclonal antibody, covalently immobilized onto CIMac™ HDZ analytical chromatographic monolith.

Attachments

Full view

2015

Methacrylate monoliths (CIM® monolithic columns) allow for very fast and efficient separations and exhibit very high binding capacities for extremely large bio-particles due to their large inner channel diameters and enhanced mass transfer characteristics.
Additionally, the ability to manufacture polymer monolithic materials ranging from analytical to large scale preparative/industrial columns has tremendous advantages. By ensuring the chromatographic properties are consistent over the whole size range, one can easily design and optimize a purification method on laboratory scale and transfer it to a production line with minimal to no additional modifications.

Until now the largest monolithic column had a volume of 8 L, which was large enough to serve the biopharmaceutics' market's needs. Now however, the capacity of that column is already at its upper limit.

By successfully employing the knowledge and experience from almost two decades of monolith production we have managed to overcome the size limitations and polymerize the largest convective chromatographic support made from one piece of material, a 40 L monolithic column.

Attachments

Full view

Immunoaffinity columns using antibodies as ligands against mammalian membrane proteins could be used for different applications in protein expresion control and, if a standard available, for concentration determination. Additionally these columns are ideal for polishing step of Fc fusion proteins of mammalian receptors.

Most importantly such columns could extract a significant amount of a pure membrane mammalian protein suitable for structural analyses, such as mass spec analysis of their glycans. Immunoaffinity chromatographic monoliths against MULT-1 transmembrane and RAE-1 GPI anchored glycoproteins were developed as a part of Glycomet project with the main goal to analyze the antigen glycan parts.

Two different  preactivated support were used:  hydrazide (HDZ) and carboxy imidazole (CDI).

Attachments

Full view

2014

Surface hydrophobicity/hydrophilicity of chromatographic stationary phases is one of the important characteristics that influence the chromatographic column performance. On the one hand, the surface should be highly hydrophilic to avoid nonspecific adsorption of sample molecules; on the other hand, the hydrophobic surface is crutial to e.g. separate the molecule isoforms.Therefore, fast and easy characterization method to evaluate the surface „hydrophobic/hydrophilic character" could be valuable.

First stage in the development of this method and the objective of this study was to evaluate the hydrophobicity of test set of 1 mL CIM columns with different ligand chemistries and densities. This was achieved by separation of protein mixture under hydrophobic interaction chromatography (HIC) conditions. Proteins were used since monoliths are used mainly in downstream of large biomolecules.

Moreover, since poor recovery under HIC conditions was observed on some columns, the research was additionally expanded with reversed phase chromatography (RPC) to obtain extra information about even more hydrophobic surface properties of monolithic columns. Therefore, after HIC step the RPC step followed and additional elution of proteins was achieved.

Attachments

Full view

Phosphoproteomics is a branch of proteomics that focuses on deriving a comprehensive view of the extent & dynamics of protein phosphorylation by way of identifying & characterizing proteins that contain a phosphate group as a posttranslational modification. One of the approaches for specific enrichment of phosphopeptides from complex samples is metal oxide affinity chromatography (MOAC), where the specific adsorption results from bridging bidentate bindings formed between the phosphate anions and the surface of a metal oxide, such as TiO2, ZrO2, Fe2O3, and Al2O3. In presented study, a rutile TiO2 nanoparticles were bound to a previously polymerised CIM hydroxy monoliths.

Attachments

Full view

Determining the concentration of viruses is a crucial step in any production process. The most commonly used methods for virus quantification are either based on the infectivity of the virus (plaque assay, TCID50) determination of their genomic material (qPCR), or protein content (SRID, ELISA) and are very cumbersome and time consuming. HPLC analytical methods represent a fast alternative to these assays since they provide information on the virus content and purity in a matter of minutes. Due to the structural properties of the monolithic supports, monolithic analytical columns offer a great advantage over particle based HPLC columns in terms of time and their ability to separate large biomolecules, like viruses, VLPs, pDNA.

In this poster the performance of the CIMac™ Adeno Analytical Column – a monolith based anion exchange column, designed for fast and reproducible analyses of adenoviruses was evaluated. CIMac Adeno column can be used for designing a fast finger printing method that is applicable for monitoring the DSP production process of adenoviruses. Once the basic analytical parameters like linearity and sensitivity are determined using a purified adenoviral standard, the metod can be applied for quantitative determination of adenoviruses.

Attachments

Full view

Enrichment of phosphopeptides prior to LC-MS analysis is a crucial sample preparation step because of their low stoichiometry in biological sample, longer retention on reversed phase columns, and lower ionization efficiency compared to non-phosphorylated peptides [1].The use of metal oxides, most prominently of TiO2 enabled efficient and relatively simple phosphopeptide-enrichment. In this study a new monolithic column from BIA Separations containing immobilized TiO2-nanoparticles was tested for its ability to enrich phosphopeptides. The TiO2-column was also tested for possible carryover originating from biological samples. In conclusion, tested monolithic TiO2 columns show significant binding ability for phosphopeptides and are considered as suitable for phosphopeptide enrichment.

Attachments

Full view