2000

Production and downstream processing in biotechnology requires fast and accurate control of each step in the process. Liquid chromatography of biopolymers on so-called soft supports is typically slow, often causing significant product degradation. One way of improving these boundary conditions in liquid chromatography is the use of monolithic adsorbents. The basis for fast separations with such media is a reduced mass transfer resistance owing to the fact that pore diffusion is practically non-existent [1]. Chromatography with compact, porous units such as monolithic columns is being used increasingly for analytical and preparative separations of biopolymers with apparent molecular mass ranging from several thousand to up to several million [2]. This paper describes the use of a CIM® Convective Interaction Media [3] for fast in-process analyses and preparative separations (up-scaling) of pharmaceutically relevant biopolymers such as clotting factor IX. Human factor IX is a vitamin K-dependent multidomain glycoprotein synthesized in liver [4]. The absence or a defect of factor IX causes haemophilia B, a genetic disease in which the clotting cascade is disturbed. The concentration of factor IX in human plasma is about 5 μg/ml (0.1 μM). Because of the low concentration in human plasma, isolation of clotting factor IX has been performed by a combination of different chromatographic methods. However, it has not been possible to remove vitronectin, one of the final contaminants from factor IX purified with conventional gel supports used in the manufacturing process of commercial factor IX preparations. This paper investigates the application of CIM® monolithic columns for the separation of vitronectin from factor IX and fast in-process control of factor IX [5].

Attachments

Full view

CIM® disk monolithic columns are monolithic columns based on glycidyle methacrylate ethylene dimethacrylate copolymers. They have become popular for separation of proteins and polynucleotides. A method for directed synthesis of peptides on these monoliths was developed. With a peptide directed against human blood coagulation factor VIII, the functionality of the CIM® disk monolithic column was checked.

Attachments

Full view

Monoliths are becoming very attractive stationary phases due to their advantageous hydrodynamic characteristics. The main difference in comparison to conventional particle beds is in their structure. Conventional particle based supports consist of few-micrometer sized porous particles while the monoliths consist of a single piece of porous material. The pores are highly interconnected forming a network of channels. Since the flow of the liquid within the channels is driven by the pressure difference, the molecules to be separated are transported to the active sites located on the surface of the channels by convection increasing their mobility by several orders of magnitude. Because of that, it is possible to perform an efficient separation of large molecules within a very short time. Furthermore, the efficiency as well as the dynamic binding capacity are independent on linear velocity within the range of tested flow rates.

Glycidyl methacrylate based monoliths were introduced in 1990. They were polymerised from glycidyl methacrylate (GMA) and ethylene dimethacrylate (EDMA) in the presence of porogens and an initiator. So far they have been successfully applied in a variety of different applications on an analytical scale: for separation and purification of proteins, DNA, smaller molecules like organic acids, hydroxybenzoates, oligonucleotides and peptides as well as sensors incorporated in a FIA system1.

Preparation of large volume GMA-EDMA monoliths is however problematic. The reason is an increase of the temperature inside the monomer mixture during polymerisation since the reaction is highly exothermic. Because of the bulk polymerisation, temperature increase inside the monomer mixture during the polymerisation can not be avoided, resulting in an extremely inhomogeneous structure of the monolith2. In this work, we introduce an approach for the construction of large scale monoliths in the annulus shape and demonstrate their applicability for chromatographic separation and purification.

Attachments

Full view

1999

High performance membrane chromatography (HPMC) proved to be a very efficient method for fast protein separations. Recently, it was shown to be applicable also for the isocratic separation of plasmid DNAconformations. However, no study about the separation of small molecules was performed until now. In this work, we investigated the possibility of gradient and isocratic separations of small molecules with Convective Interaction Media (CIM) disks of different chemistries. We proved that it was possible to achieve efficient separations of oligonucleotides and peptides in the ion-exchange mode as well as the separation of small hydrophobic molecules in the reversed phase mode. Fairly good separation of four oligonucleotides could be achieved on the disk of 0.3 mm thickness. The effect of the gradient parameters on the resolution in the case of gradient mode was studied and compared with the separation under isocratic conditions.

It was shown that similar peak resolution can be achieved in both gradient and isocratic modes. In addition, it was found that the flow rate does not have a pronounced influence on the resolution in the flow rate range between 1 and 10 mL/min. However, it seems that the resolution with the flow rate even slightly increases as a consequence of the increased pore accessibility. In accordance with conventional particle HPLC columns, the resolution increases with the monolith thickness. On the other hand, the mobile phase composition has to be carefully adjusted to obtain optimal resolution, especially in the case of isocratic separations. Because of this feature, CIM monoliths seem to be competitive to other, commercially available stationary phases.

Attachments

Full view

Organic acids are important metabolites of several biochemical pathways in microorganisms and as such they are frequent main or by-products in different bioprocesses. Consequently, a demand for their monitoring is often present. One of the most applied methods for organic acids determination is certainly HPLC using different separation mechanisms such as reversed-phase, ion-exchange or ion-exclusion chromatography, all based on separation under isocratic flow conditions. To achieve the isocratic separation, multiple steps of adsorption-desorption process are needed and therefore conventional chromatographic columns with long layer of separation material were considered as a necessary tool for achieving this effect.

Recently, it was shown that isocratic separation could also be performed on thin monolithic layers. The isocratic separations of plasmid DNA conformers (1), oligonucleotides (2, 3) and peptides (3) in the ion-exchange mode were demonstrated as well as isocratic reversed-phase separation of a mixture of steroids was obtained (3) all on thin GMA-EDMA monoliths commercially available under trademark CIM™ (Convective Interaction Media). The results indicated the possibility of applying CIM™ monolithic columns also for isocratic separation of some other small charged molecules. Since the average analysis time using CIM™ disk monolithic columns is up to a few minutes, these supports can be a material of choice for separation of organic acids.

Attachments

Full view

Found recently serine protease called, as tissue plasminogen activator (t-PA) is able to dissolve efficiently the blood clots. Thus this protein seems to be extremely useful in clinical practice in the cases of heart attack victims.

Real process of fibrinolysis in human blood system represents very complicated network of simultaneous biological events. It is clear that t-PA has a branched set of functional complements with their own, and probably different, affinity to this enzyme. It seems to be possible and quite interesting to investigate all these pairs separately creating them in vitro. At the same time, it is clear that the affinity chromatography approach could become as the most convenient way to create such biological pairs.

The recently developed High Performance Membrane (Monolith) Chromatography (HPMC) is quite promising in this regard, because of its high capacity and selectivity, combined with low backpressure and short operation times. Due to the inherent speed of the isolation it facilitates the recovery of a biologically active product, since the exposure to putative denaturing influences.

Attachments

Full view

Convective Interaction Technology (CIM®) offers a number of benefits for the purification of large molecules in comparison with conventional chromatography. The innovative matrix, cast as a single homogeneous piece, means that monolithic columns have a high pressure tolerance and allow fast operating flow rates.

Because the matrix structure is composed of large pores, mass transfer is essentially convective in contrast to conventional chromatography beads, where mass transfer is essentially diffusive. Therefore, CIM can be used at high flow rates without compromising binding capacity.

For these reasons, a monolithic column with anion exchange properties (CIM® QA) was selected to purify a very large protein (8 Mega Dalton) extracted from a marine mollusc.

Because 150 g of protein was required to perform preclinical trials, a scale-up of the process had to be designed and implemented. Early stage process development was carried out on an 8 mL column to determine the column loading capacity as well as the yield and the process reproducibility.

To improve binding on the column, stabilising agents had to be removed prior to this purification step. The protein had been observed to precipitate within hours of the removal of these reagents. Therefore, a suitable time frame for protein processing had to accommodate this instability.

Attachments

Full view

Monolithic chromatographic supports can efficiently be used for fast separation and purification of different types of molecules, both in the analytical and preparative scale. CIM Convective Interaction Media™ monolithic columns are macroporous polymeric supports that allow in-seconds separation of proteins and other biomolecules in gradient and isocratic modes.

In this work, the results showing the main characteristics of CIM™ columns are presented. The breakthrough curves at different flow rates were measured and it is shown that the dynamic binding capacity is practically unaffected by increased flow rates. The adsorption isotherm is almost rectangular exhibiting a highly favourable conditions for binding the tested components to the matrix. Furthermore, relatively high binding capacity is still maintained at elevated ionic strengths of the binding buffer. Finally, the HETP values of the components with different molecular masses are presented.

Attachments

Full view

There are many different chromatographic supports on market. Although main part of them are particle shaped supports, the so-called monoliths are becoming increasingly more important. Particle based supports are commonly uniform-sized of some micron with high porosity. The pores are required to increase the specific surface area and, as a consequence, to increase the binding capacity. Since the pores are closed on one side, the liquid inside them is stagnant and the movement of molecules is governed by diffusion. Therefore, to obtain a good separation and a high binding capacity, low flow rates should commonly be applied. This results in flowdependent resolution of the separation and dynamic binding capacity.

In contrast to conventional porous particles the morphological characteristics of CIM supports are characterised by a single monolithic unit that contains pores, opened on both sides. These pores are highly interconnected forming a flow-through a network. All the mobile phase is forced to run through these open pores, therefore, the mass transfer between stationary and mobile phases is based on convective flow. One of the key features of monolithic units is their pore size distribution that should enable low back pressure at high throughputs together with high specific surface area, needed for high binding capacity.

In this work, dynamic characteristics of CIM disks bearing weak anion exchange groups for binding Bovine Serum Albumin (BSA) were studied. Reproducibility was checked and protein concentration as well as the flow rate were varied. Preliminary results confirm the flow independence of the dynamic binding capacity in the whole range of applied flow rates.

Attachments

Full view

CIM (Convective Interaction Media) represent a new generation of chromatographic supports. In contrast to conventional particle supports, where the void volume between individual porous particles is unavoidable, CIM supports consist of a single monolith with open channels. In this way, molecules to be separated are transported into the pores by convection, resulting in short separation times.

CIMsupports proved to be very efficient for extremely fast separations of proteins in ion exchange, hydrophobic interaction and affinity chromatography mode. Recently, the successful separation of DNA as well as some smaller molecules like e.g. peptides and oligonucleotides were also performed.

All the above mentioned separations were carried out on an analytical scale with the use of 0.34 mL CIM discs. The scale-up of monolithic units was limited mainly due to the problems associated to the mechanical stability, poor sample distribution and higher backpressures. The change from the axial to radial flow enables the design of the so-called 8 and 80mLCIM tubes. They were basically designed for very fast purification of macromolecules.

In this work we present some basic characteristics of these newly developed units in terms of separation and binding capacity. In addition, some practical examples will be given and discussed as well.

Attachments

Full view

Isolation and purification of proteins, peptides and polynucleotides as well as fractionation of biological mixtures are of great importance both for the solution of theoretical problems in chemistry and biology and the
realization of practical plans connected, in particular, with the production of medicines on the basis of large biomolecules. An important problem in the production of biological substances for medicine is to work out the step of their isolation and fine purification, e.g. creation of high performance separation methods, particularly, the chromatographic techniques. Here, fast and efficient affinity separations based on dynamical interaction of biocomplements play very important role.

High Performance Membrane (Monolith) Chromatography (HPMC) allows to solve all problems of High Liquid Chromatography (HPLC) demonstrating a number of number of distinct advantages. A small thickness of separation layer and opened structure of throughput channels where the separation takes place cause minimum difussion resistance for normal mass transport of the substances as well as low working back pressure and thus, the possibility of use of high elution flow rates.

Attachments

Full view

In order to enable the detection of low abundance proteins from human plasma, it is necessary to remove high abundance proteins. Among them, human serum albumin and immonoglobulin G represent more than 75 % of all abundance proteins. There are many strategies developed for an efficient removal of these two main proteins, the majority of them rely on highly selective, yet expensive affinity techniques. In this work an affinity monolithic column was used for the depletion of IgG. For the removal of HSA we tested an alternative - complementary approach, where an ion-exchange mode was used as one of the depletion steps. the results were compared to the ones obtained by by using the prseudoaffinity columns.

Attachments

Full view