On May 12th, the biaseparations.com website will be retired and migrated tosartorius.com.Learn moreabout our combined offering today!
2000

Production and downstream processing in biotechnology requires fast and accurate control of each step in the process. Liquid chromatography of biopolymers on so-called soft supports is typically slow, often causing significant product degradation. One way of improving these boundary conditions in liquid chromatography is the use of monolithic adsorbents. The basis for fast separations with such media is a reduced mass transfer resistance owing to the fact that pore diffusion is practically non-existent [1]. Chromatography with compact, porous units such as monolithic columns is being used increasingly for analytical and preparative separations of biopolymers with apparent molecular mass ranging from several thousand to up to several million [2]. This paper describes the use of a CIM® Convective Interaction Media [3] for fast in-process analyses and preparative separations (up-scaling) of pharmaceutically relevant biopolymers such as clotting factor IX. Human factor IX is a vitamin K-dependent multidomain glycoprotein synthesized in liver [4]. The absence or a defect of factor IX causes haemophilia B, a genetic disease in which the clotting cascade is disturbed. The concentration of factor IX in human plasma is about 5 μg/ml (0.1 μM). Because of the low concentration in human plasma, isolation of clotting factor IX has been performed by a combination of different chromatographic methods. However, it has not been possible to remove vitronectin, one of the final contaminants from factor IX purified with conventional gel supports used in the manufacturing process of commercial factor IX preparations. This paper investigates the application of CIM® monolithic columns for the separation of vitronectin from factor IX and fast in-process control of factor IX [5].

Attachments

Full view

1999

High performance membrane chromatography (HPMC) proved to be a very efficient method for fast protein separations. Recently, it was shown to be applicable also for the isocratic separation of plasmid DNAconformations. However, no study about the separation of small molecules was performed until now. In this work, we investigated the possibility of gradient and isocratic separations of small molecules with Convective Interaction Media (CIM) disks of different chemistries. We proved that it was possible to achieve efficient separations of oligonucleotides and peptides in the ion-exchange mode as well as the separation of small hydrophobic molecules in the reversed phase mode. Fairly good separation of four oligonucleotides could be achieved on the disk of 0.3 mm thickness. The effect of the gradient parameters on the resolution in the case of gradient mode was studied and compared with the separation under isocratic conditions.

It was shown that similar peak resolution can be achieved in both gradient and isocratic modes. In addition, it was found that the flow rate does not have a pronounced influence on the resolution in the flow rate range between 1 and 10 mL/min. However, it seems that the resolution with the flow rate even slightly increases as a consequence of the increased pore accessibility. In accordance with conventional particle HPLC columns, the resolution increases with the monolith thickness. On the other hand, the mobile phase composition has to be carefully adjusted to obtain optimal resolution, especially in the case of isocratic separations. Because of this feature, CIM monoliths seem to be competitive to other, commercially available stationary phases.

Attachments

Full view

Organic acids are important metabolites of several biochemical pathways in microorganisms and as such they are frequent main or by-products in different bioprocesses. Consequently, a demand for their monitoring is often present. One of the most applied methods for organic acids determination is certainly HPLC using different separation mechanisms such as reversed-phase, ion-exchange or ion-exclusion chromatography, all based on separation under isocratic flow conditions. To achieve the isocratic separation, multiple steps of adsorption-desorption process are needed and therefore conventional chromatographic columns with long layer of separation material were considered as a necessary tool for achieving this effect.

Recently, it was shown that isocratic separation could also be performed on thin monolithic layers. The isocratic separations of plasmid DNA conformers (1), oligonucleotides (2, 3) and peptides (3) in the ion-exchange mode were demonstrated as well as isocratic reversed-phase separation of a mixture of steroids was obtained (3) all on thin GMA-EDMA monoliths commercially available under trademark CIM™ (Convective Interaction Media). The results indicated the possibility of applying CIM™ monolithic columns also for isocratic separation of some other small charged molecules. Since the average analysis time using CIM™ disk monolithic columns is up to a few minutes, these supports can be a material of choice for separation of organic acids.

Attachments

Full view

Found recently serine protease called, as tissue plasminogen activator (t-PA) is able to dissolve efficiently the blood clots. Thus this protein seems to be extremely useful in clinical practice in the cases of heart attack victims.

Real process of fibrinolysis in human blood system represents very complicated network of simultaneous biological events. It is clear that t-PA has a branched set of functional complements with their own, and probably different, affinity to this enzyme. It seems to be possible and quite interesting to investigate all these pairs separately creating them in vitro. At the same time, it is clear that the affinity chromatography approach could become as the most convenient way to create such biological pairs.

The recently developed High Performance Membrane (Monolith) Chromatography (HPMC) is quite promising in this regard, because of its high capacity and selectivity, combined with low backpressure and short operation times. Due to the inherent speed of the isolation it facilitates the recovery of a biologically active product, since the exposure to putative denaturing influences.

Attachments

Full view

Convective Interaction Technology (CIM®) offers a number of benefits for the purification of large molecules in comparison with conventional chromatography. The innovative matrix, cast as a single homogeneous piece, means that monolithic columns have a high pressure tolerance and allow fast operating flow rates.

Because the matrix structure is composed of large pores, mass transfer is essentially convective in contrast to conventional chromatography beads, where mass transfer is essentially diffusive. Therefore, CIM can be used at high flow rates without compromising binding capacity.

For these reasons, a monolithic column with anion exchange properties (CIM® QA) was selected to purify a very large protein (8 Mega Dalton) extracted from a marine mollusc.

Because 150 g of protein was required to perform preclinical trials, a scale-up of the process had to be designed and implemented. Early stage process development was carried out on an 8 mL column to determine the column loading capacity as well as the yield and the process reproducibility.

To improve binding on the column, stabilising agents had to be removed prior to this purification step. The protein had been observed to precipitate within hours of the removal of these reagents. Therefore, a suitable time frame for protein processing had to accommodate this instability.

Attachments

Full view

Isolation and purification of proteins, peptides and polynucleotides as well as fractionation of biological mixtures are of great importance both for the solution of theoretical problems in chemistry and biology and the
realization of practical plans connected, in particular, with the production of medicines on the basis of large biomolecules. An important problem in the production of biological substances for medicine is to work out the step of their isolation and fine purification, e.g. creation of high performance separation methods, particularly, the chromatographic techniques. Here, fast and efficient affinity separations based on dynamical interaction of biocomplements play very important role.

High Performance Membrane (Monolith) Chromatography (HPMC) allows to solve all problems of High Liquid Chromatography (HPLC) demonstrating a number of number of distinct advantages. A small thickness of separation layer and opened structure of throughput channels where the separation takes place cause minimum difussion resistance for normal mass transport of the substances as well as low working back pressure and thus, the possibility of use of high elution flow rates.

Attachments

Full view

In order to enable the detection of low abundance proteins from human plasma, it is necessary to remove high abundance proteins. Among them, human serum albumin and immonoglobulin G represent more than 75 % of all abundance proteins. There are many strategies developed for an efficient removal of these two main proteins, the majority of them rely on highly selective, yet expensive affinity techniques. In this work an affinity monolithic column was used for the depletion of IgG. For the removal of HSA we tested an alternative - complementary approach, where an ion-exchange mode was used as one of the depletion steps. the results were compared to the ones obtained by by using the prseudoaffinity columns.

Attachments

Full view