The present study describes a new methodology to quantify and monitor the quality of supercoiled (sc) plasmid DHA (pDLIA), using a monolithic column based on anion-exchange chromatography. This analytical method with UV detection allows distinguishing the plasmid isoforms by a NaCl stepwise gradient. The selectivity, Linearity, accuracy, reproducibility and repeatability of the method have been evaluated, and the lower quantification and detection limits were also established. The validation was performed according to the guidelines, being demonstrated that the method is precise and accurate for a sc plasmid concentration up to 200 µg/mL. The main advance achieved by using this monolithic method is the possibility to quantify the sc plasmid in a sample containing other plasmid topologies, in a 4 minutes experiment. This work also intends to evaluate the possibility to assess the sc pDNA present in more complex samples, allowing the control of the samples recovered from different bioprocess steps.

Attachments

Full view

Application of plasmid DNA for gene therapy and vaccination has gained substantial interest in the last two decades. Topological homogeneity and impurity content are crucial for therapeutic usage of pDNA. Downstream processing has major influence on achieving regulatory demands in pDNA production and in order to get optimal purity different purification techniques have to be applied. It was demonstrated that methacrylate monoliths can be used for efficient purification process of plasmid DNA. High dynamic binding capacities and high flow rates of methacrylate monolith enable excellent purity and productivity.

Attachments

Full view

Monolith chromatography media coupled with metal affinity ligands proved superior to the conventional particle-based matrix as a plasmid DNA (pDNA) purification platform. By harnessing the differential affinity of pDNA, RNA. Host cell proteins and endotoxin to copper ions in the solution a majority of endotoxin (90%) was removed from the alkaline cell lysate using CuCl2-induced precipitation. RNA and remaining endotoxin were subsequently processed by copper immobilized metal affinity column employing either monolith or particle-based matrix where both RNA and endotoxin were removed below detection limit with almost complete recovery of pDNA in the monolith was found to have several advantages in terms of handling feedstocks crowded with RNA in a concentration-independent manner and exhibiting flowrate-independent dynamic binding capacity for RNA. This enabled monolith-based process to be conducted at high feed concentration and flow rate. Resulting in pDNA vaccine purification at a high yield and purity and the process conditions investigated, the use of monolith column gave at least three fold higher productivity for recovery of purified pDNA as compared to the particle- based column, demonstrating its potential as a more rapid and economical platform for pDNA vaccine purification.

Attachments

Full view

Gene therapy which is becoming more and more important in human health care requires the purification of high molecular mass compounds, so called nanoparticles (e. g. viruses and plasmids). The method of choice to ensure proper purity would be chromatography.

Most of the chromatographic supports available on the market at the moment can not follow the requests for such work due to low binding capacity for large molecules, limitation with regards to the time of the separation process and requests for CIP (cleaning in place) and SIP (sanitation in place).

Monolithic supports represent a new generation of chromatographic supports. In contrast to conventional particle supports, where the void volume between individual porous particles is unavoidable, these supports consist of a single monolith highly interconnected with larger and smaller open flow-through channels. Due to the structure, molecules to be separated are transported to the active sites on the stationary phase by convection, resulting in very short separation times. This is especially true for large molecules.

In this work we will present the use of monolithic supports for the separation of different nanoparticles on analytical and preparative scales. It will be shown that monolithic supports can overcome the limitations of particle-based supports for the analytics and isolation of big molecules and represent a major step towards the safe and efficient purification or production of nanoparticles.

Attachments

Full view

Organic acids are important metabolites of several biochemical pathways in microorganisms and as such they are frequent main or by-products in different bioprocesses. Consequently, a demand for their monitoring is often present. One of the most applied methods for organic acids determination is certainly HPLC using different separation mechanisms such as reversed-phase, ion-exchange or ion-exclusion chromatography, all based on separation under isocratic flow conditions. To achieve the isocratic separation, multiple steps of adsorption-desorption process are needed and therefore conventional chromatographic columns with long layer of separation material were considered as a necessary tool for achieving this effect.

Recently, it was shown that isocratic separation could also be performed on thin monolithic layers. The isocratic separations of plasmid DNA conformers (1), oligonucleotides (2, 3) and peptides (3) in the ion-exchange mode were demonstrated as well as isocratic reversed-phase separation of a mixture of steroids was obtained (3) all on thin GMA-EDMA monoliths commercially available under trademark CIM™ (Convective Interaction Media). The results indicated the possibility of applying CIM™ monolithic columns also for isocratic separation of some other small charged molecules. Since the average analysis time using CIM™ disk monolithic columns is up to a few minutes, these supports can be a material of choice for separation of organic acids.

Attachments

Full view

High performance membrane chromatography (HPMC) proved to be a very efficient method for fast protein separations. Recently, it was shown to be applicable also for the isocratic separation of plasmid DNAconformations. However, no study about the separation of small molecules was performed until now. In this work, we investigated the possibility of gradient and isocratic separations of small molecules with Convective Interaction Media (CIM) disks of different chemistries. We proved that it was possible to achieve efficient separations of oligonucleotides and peptides in the ion-exchange mode as well as the separation of small hydrophobic molecules in the reversed phase mode. Fairly good separation of four oligonucleotides could be achieved on the disk of 0.3 mm thickness. The effect of the gradient parameters on the resolution in the case of gradient mode was studied and compared with the separation under isocratic conditions.

It was shown that similar peak resolution can be achieved in both gradient and isocratic modes. In addition, it was found that the flow rate does not have a pronounced influence on the resolution in the flow rate range between 1 and 10 mL/min. However, it seems that the resolution with the flow rate even slightly increases as a consequence of the increased pore accessibility. In accordance with conventional particle HPLC columns, the resolution increases with the monolith thickness. On the other hand, the mobile phase composition has to be carefully adjusted to obtain optimal resolution, especially in the case of isocratic separations. Because of this feature, CIM monoliths seem to be competitive to other, commercially available stationary phases.

Attachments

Full view

The rapidly growing interest in the area of proteomics induces intensive efforts to find robust, automated and sensitive high-throughput analytical tools. In this context, the concept of solid-phase digestion (ex. trypsin immobilization on a solid support[1]) has received great attention in the last years. Trypsin (EC 3.4.21.4) has been covalently immobilized on different monolithic supports and resulting bioreactors used as immobilized enzyme reactors (IMERs) for on-line digestion, peptide separation and peptide mapping. Bioreactors efficiencies were evaluated with different recombinant proteins after on-line digestion. The technique used for the separation and identification of peptides was high-performance liquid chromatography coupled with electrospray ionisation tandem mass spectrometry (LC-ESI-MS/MS).

Attachments

Full view

The only four drugs approved for the clinical treatment of Alzheirner’s Disease (tacrine. rivastigmine, donepezil and galantamine) are acetylcholinesterase inhibitors which act by maintaining high levels of acetylcholine at the muscarinic and nicotinic receptors in the central nervous system. Human acetylcholinesterase (HuAChE) represents a widely studied target enzyme and it is still object of research for the development of new drugs as enzyme inhibitors.

In a previous paper we reported the immobilisation of AChE on a silica based chromatographic column (50 x 4.6 mm 1.0.) The yeld of immobilization and the stability of the AChE-IMER were considered satisfactory, but some problems arose. The length of the IMER and the large amount of enzyme covalently bound to the chromatographic support resulted in catalysis product long elution times and some inhibitors aspecific matrix absorption with delayed enzyme activity recovery. In order to avoid these complications and considering the high rate of AChE enzymatic reaction. we decided to reduce the dimension of the solid support for immobilization, hence the amount of immobilized enzyme, by selecting a monolithic matrix disk (12 x 3 mm I.D.).

CIM® (Convective Interaction Media) monolithic supports (Biaseparations. Lubiana) represent a novel generation of stationary phases used for liquid chromatography, bioconversions, and solid phase synthesis. As opposed to individual particles packed into chromatographic columns, CIM® supports are cast as continuous homogeneous phases and provide high rates of mass transfer at lower back pressure.

In the present work a CIMK disk with immobilised human recombinant acetylcholinesterase (HuAChE-ClM® Disk) was developed. The activity of immohilised enzyme, the long term stability and reproducibility were tested. HuAChE-CIM® disk was applied as an immobilised enzyme micro-reactor (micro-IMER) in on-line HPLC system for inhibitory potency determination of known AChE inhibitors.

Full view

The analysis of molecular interactions is a key part of the drug discovery process, and analytical techniques are available for studying in vitro the ligand/target complex since the early stage of the drug development process.

With regard to the assessment of the activity of chemical libraries, the affinity chromatography on HPLC immobilized-enzyme column (or immobilized enzyme reactors, IMER) is one of most promising methodologies for HTS applications.

Human recombinant acetylcholinesterase (hAChE) represents a well-known target for drug-discovery in Alzheimer’s Disease.

Attachments

Full view

The Inter-alpha inhibitor protein family is comprised of complex plasma proteins that consist of a combination of multiple polypeptide chains (light and heavy chains) covalently linked by a chondroitin sulfate chain. The major forms found in human plasma in high concentration are Inter-alpha inhibitor (Ial), which consists of two heavy chains (Hl & H2) and a single light chain, and Pre-alpha Inhibitor (Pal), which consists of one heavy (H3) and one light chain (Fig 1). The light chain (bikunin) is known to inhibit several serine proteases, such as trypsin, human leukocyte chistase, plasmin and cathepsin G which are involved in inflammation, sepsis, tumor invasion and formation of metastasis. Recently, a monoclonal antibody against human inter-alpha inhibitor proteins (MAli 6931) was developed in our laboratory.

Attachments

Full view